Validity and limits of the rebound tonometer (ICare®): clinical study.

Gian Luca Scuderi1, Nikhil Carlo Cascone, Federico Regine, Andrea Perdicchi, Angelica Cerulli, Santi Maria Recupero.   

Abstract

PURPOSE: The aim of this study was to evaluate the measurement of intraocular pressure (IOP) using a new induction/impact rebound tonometer (ICare®) compared with Goldmann applanation tonometry (GAT). We also aimed to quantify the systematic and random errors (bias) of the 2 methods, to evaluate the sensitivity and specificity of the ICare® tonometer in identifying patients with 21 mmHg or more measured with the GAT, and to study the influence of corneal thickness on IOP measurement with the 2 tonometers.
METHODS: We compared the IOP values obtained with the 2 instruments in 97 patients.
RESULTS: Analysis based on the Bland and Altman method revealed that the IOP values recorded with the ICare® tonometer were slightly higher than those obtained with the GAT. The estimated bias for right eye measurements was 0.78 mmHg with 95% limits of agreement ±3.55 mmHg. This overestimation, which is not clinically relevant, was confirmed when we used the IOP values corrected according to central corneal thickness for data analysis. The sensitivity and specificity were 0.90 and 0.95, respectively.
CONCLUSIONS: The ICare® tonometer proved to be comparable with other nonconventional tonometers and can be used by nonophthalmologists and paramedical personnel during screening tests of populations. In addition, the ICare® tonometer could be considered a valid alternative to GAT when GAT is not available.

Entities:  

Mesh:

Year:  2011        PMID: 20853257     DOI: 10.5301/EJO.2010.3712

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  25 in total

1.  Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects.

Authors:  Ioannis Halkiadakis; Aimilianos Stratos; George Stergiopoulos; Eleni Patsea; Sotiris Skouriotis; Panagiotis Mitropoulos; Dimitrios Papaconstantinou; Gerasimos Georgopoulos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08       Impact factor: 3.117

2.  Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects.

Authors:  Yoshitake Kato; Shunsuke Nakakura; Naoko Matsuo; Kayo Yoshitomi; Marina Handa; Hitoshi Tabuchi; Yoshiaki Kiuchi
Journal:  Int Ophthalmol       Date:  2017-04-09       Impact factor: 2.031

3.  Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients.

Authors:  Milena Pahlitzsch; Jeanette Brünner; Johannes Gonnermann; Anna-Karina B Maier; Necip Torun; Eckart Bertelmann; Matthias Kj Klamann
Journal:  Int J Ophthalmol       Date:  2016-11-18       Impact factor: 1.779

4.  [Comparison of the iCare tonometer with the Goldmann tonometer in Malawi].

Authors:  J Hohmann; M Schulze-Schwering; T Chirambo Nyaka; V Moyo; P C Kayange; D Doycheva; N H Batumba; M S Spitzer
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

5.  Deep topical anesthesia with ropivacaine-soaked sponge for phacoemulsification.

Authors:  Gianluca Scuderi; Luca Scuderi; Silvia Calafiore; Vito Fenicia; Solmaz Abdolrahimzadeh
Journal:  Int Ophthalmol       Date:  2019-05-31       Impact factor: 2.031

6.  Intraocular pressure variation during colorectal laparoscopic surgery: standard pneumoperitoneum leads to reversible elevation in intraocular pressure.

Authors:  Andrea Grosso; Gitana Scozzari; Fabrizio Bert; Maria Antonietta Mabilia; Roberta Siliquini; Mario Morino
Journal:  Surg Endosc       Date:  2013-04-03       Impact factor: 4.584

7.  The analysis of the glaucoma screening event results obtained during the World Glaucoma Week in Zagreb, Croatia.

Authors:  Mia Zorić Geber; Kristina Lončarić; Jelena Škunca Herman; Iva Krolo; Rašeljka Tadić; Marin Belak; Ana Koluder; Željko Kaurić; Lana Knežević; Katia Novak-Lauš; Tina Runjić; Zoran Vatavuk
Journal:  Int Ophthalmol       Date:  2022-05-14       Impact factor: 2.029

8.  Cocaine snorting may induce ocular surface damage through corneal sensitivity impairment.

Authors:  Flavio Mantelli; Alessandro Lambiase; Marta Sacchetti; Valerio Orlandi; Alba Rosa; Pietro Casella; Stefano Bonini
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-02-03       Impact factor: 3.117

9.  Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery.

Authors:  Ken Hayashi; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-06-28       Impact factor: 2.447

10.  Wound stability and surgically induced corneal astigmatism after transconjunctival single-plane sclerocorneal incision cataract surgery.

Authors:  Ken Hayashi; Soichiro Ogawa; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2016-10-06       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.