Literature DB >> 20850330

Dosimetry of gamma chamber blood irradiator using Gafchromic EBT film.

S Vandana1, V S Shaiju, S D Sharma, S Mhatre, S Shinde, G Chourasiya, Y S Mayya.   

Abstract

Gafchromic films are increasingly being used for dosimetry in medical and industrial applications of ionizing radiation because of their favorable characteristics such as self developing in nature, easy to handle, dose rate independent response, insensitivity to normal room lights, high resolution and insensitivity to variation in the environment conditions. The dosimetry measurements using Gafchromic EBT film, Fricke dosimeter and thermoluminescence (TL) dosimeter were carried out on gamma blood irradiators to establish the suitability of Gafchromic EBT film in such applications. The dose rates determined by Gafchromic EBT film, Fricke dosimeter and TL dosimeter powder are found in good agreement to one another within the uncertainty of measurement. The two-dimensional dose distributions determined using Gafchromic EBT film reflects the expected dose distribution inside the sample compartment of the blood irradiator. The results of this study establish Gafchromic EBT film a suitable dosimeter for routine dosimetry on gamma blood irradiators.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20850330     DOI: 10.1016/j.apradiso.2010.08.018

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  4 in total

1.  Radiation dose verification of an X-ray based blood irradiator using EBT3 radiochromic films calibrated using Gamma Knife machine.

Authors:  Khaled Soliman; Marouf Adili; Abdullah Alrushoud
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-07

2.  Diacetylene-Based Colorimetric Radiation Sensors for the Detection and Measurement of γ Radiation during Blood Irradiation.

Authors:  Apoorva Mittal; Shalini Verma; Gopishankar Natanasabapathi; Pratik Kumar; Akhilesh K Verma
Journal:  ACS Omega       Date:  2021-03-29

3.  Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations.

Authors:  Parvin Mohammadyari; Mehdi Zehtabian; Sedigheh Sina; Ali Reza Tavasoli; Reza Faghihi
Journal:  J Appl Clin Med Phys       Date:  2014-01-04       Impact factor: 2.102

4.  Chondrocytes differentiated from human induced pluripotent stem cells: Response to ionizing radiation.

Authors:  Ewelina Stelcer; Katarzyna Kulcenty; Wiktoria Maria Suchorska
Journal:  PLoS One       Date:  2018-10-23       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.