Literature DB >> 20840893

Compensation of modelling errors due to unknown domain boundary in electrical impedance tomography.

Antti Nissinen1, Ville Petteri Kolehmainen, Jari P Kaipio.   

Abstract

Electrical impedance tomography is a highly unstable problem with respect to measurement and modeling errors. This instability is especially severe when absolute imaging is considered. With clinical measurements, accurate knowledge about the body shape is usually not available, and therefore an approximate model domain has to be used in the computational model. It has earlier been shown that large reconstruction artefacts result if the geometry of the model domain is incorrect. In this paper, we adapt the so-called approximation error approach to compensate for the modeling errors caused by inaccurately known body shape. This approach has previously been shown to be applicable to a variety of modeling errors, such as coarse discretization in the numerical approximation of the forward model and domain truncation. We evaluate the approach with a simulated example of thorax imaging, and also with experimental data from a laboratory setting, with absolute imaging considered in both cases. We show that the related modeling errors can be efficiently compensated for by the approximation error approach. We also show that recovery from simultaneous discretization related errors is feasible, allowing the use of computationally efficient reduced order models.

Mesh:

Year:  2010        PMID: 20840893     DOI: 10.1109/TMI.2010.2073716

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  12 in total

1.  Calderón's method on an elliptical domain.

Authors:  P A Muller; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2013-05-29       Impact factor: 2.833

2.  Phantom Studies of Fused-Data TREIT Using Only Biopsy-Probe Electrodes.

Authors:  Ethan K Murphy; Xiaotian Wu; Alicia C Everitt; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

3.  Absolute Reconstructions Using Rotational Electrical Impedance Tomography for Breast Cancer Imaging.

Authors:  Ethan K Murphy; Aditya Mahara; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2016-12-15       Impact factor: 10.048

4.  Graph Convolutional Networks for Model-Based Learning in Nonlinear Inverse Problems.

Authors:  William Herzberg; Daniel B Rowe; Andreas Hauptmann; Sarah J Hamilton
Journal:  IEEE Trans Comput Imaging       Date:  2021-12-02

5.  Efficient Simultaneous Reconstruction of Time-Varying Images and Electrode Contact Impedances in Electrical Impedance Tomography.

Authors:  Gregory Boverman; David Isaacson; Jonathan C Newell; Gary J Saulnier; Tzu-Jen Kao; Bruce C Amm; Xin Wang; David M Davenport; David H Chong; Rakesh Sahni; Jeffrey M Ashe
Journal:  IEEE Trans Biomed Eng       Date:  2016-06-08       Impact factor: 4.538

6.  Corrections to linear methods for diffuse optical tomography using approximation error modelling.

Authors:  Tanja Tarvainen; Ville Kolehmainen; Jari P Kaipio; Simon R Arridge
Journal:  Biomed Opt Express       Date:  2010-07-16       Impact factor: 3.732

7.  Modelling of an oesophageal electrode for cardiac function tomography.

Authors:  J Nasehi Tehrani; C Jin; A L McEwan
Journal:  Comput Math Methods Med       Date:  2012-03-15       Impact factor: 2.238

8.  A Multitasking Electrical Impedance Tomography System Using Titanium Alloy Electrode.

Authors:  Abdalla Salama; Amin Malekmohammadi; Shahram Mohanna; Rajprasad Rajkumar
Journal:  Int J Biomed Imaging       Date:  2017-10-31

9.  Electrical Impedance Tomography-Based Abdominal Subcutaneous Fat Estimation Method Using Deep Learning.

Authors:  Kyounghun Lee; Minha Yoo; Ariungerel Jargal; Hyeuknam Kwon
Journal:  Comput Math Methods Med       Date:  2020-06-11       Impact factor: 2.238

10.  Real-Time Detection of Hemothorax and Monitoring its Progression in a Piglet Model by Electrical Impedance Tomography: A Feasibility Study.

Authors:  Lin Yang; Chao Zhang; Wenbo Liu; Hang Wang; Junying Xia; Benyuan Liu; Xuetao Shi; Xiuzhen Dong; Feng Fu; Meng Dai
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.