Literature DB >> 20838900

First long term in vivo study on subdurally implanted micro-ECoG electrodes, manufactured with a novel laser technology.

C Henle1, M Raab, J G Cordeiro, S Doostkam, A Schulze-Bonhage, T Stieglitz, J Rickert.   

Abstract

A novel computer aided manufacturing (CAM) method for electrocorticography (ECoG) microelectrodes was developed to be able to manufacture small, high density microelectrode arrays based on laser-structuring medical grade silicone rubber and high purity platinum. With this manufacturing process, we plan to target clinical applications, such as presurgical epilepsy monitoring, functional imaging during cerebral tumor resections and brain-computer interface control in paralysed patients, in the near future. This paper describes the manufacturing, implantation and long-term behaviour of such an electrode array. In detail, we implanted 8-channel electrode arrays subdurally over rat cerebral cortex over a period of up to 25 weeks. Our primary objective was to ascertain the electrode's stability over time, and to analyse the host response in vivo. For this purpose, impedance measurements were carried out at regular intervals over the first 18 weeks of the implantation period. The impedances changed between day 4 and day 7 after implantation, and then remained stable until the end of the implantation period, in accordance with typical behaviour of chronically implanted microelectrodes. A post-mortem histological examination was made to assess the tissue reaction due to the implantation. A mild, chronically granulated inflammation was found in the area of the implant, which was essentially restricted to the leptomeninges. Overall, these findings suggest that the concept of the presented ECoG-electrodes is promising for use in long-term implantations.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20838900     DOI: 10.1007/s10544-010-9471-9

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  28 in total

1.  Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity.

Authors:  Thomas J Oxley; Nicholas L Opie; Sam E John; Gil S Rind; Stephen M Ronayne; Tracey L Wheeler; Jack W Judy; Alan J McDonald; Anthony Dornom; Timothy J H Lovell; Christopher Steward; David J Garrett; Bradford A Moffat; Elaine H Lui; Nawaf Yassi; Bruce C V Campbell; Yan T Wong; Kate E Fox; Ewan S Nurse; Iwan E Bennett; Sébastien H Bauquier; Kishan A Liyanage; Nicole R van der Nagel; Piero Perucca; Arman Ahnood; Katherine P Gill; Bernard Yan; Leonid Churilov; Christopher R French; Patricia M Desmond; Malcolm K Horne; Lynette Kiers; Steven Prawer; Stephen M Davis; Anthony N Burkitt; Peter J Mitchell; David B Grayden; Clive N May; Terence J O'Brien
Journal:  Nat Biotechnol       Date:  2016-02-08       Impact factor: 54.908

2.  Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate.

Authors:  Alan D Degenhart; James Eles; Richard Dum; Jessica L Mischel; Ivan Smalianchuk; Bridget Endler; Robin C Ashmore; Elizabeth C Tyler-Kabara; Nicholas G Hatsopoulos; Wei Wang; Aaron P Batista; X Tracy Cui
Journal:  J Neural Eng       Date:  2016-06-28       Impact factor: 5.379

3.  Strategies for optical control and simultaneous electrical readout of extended cortical circuits.

Authors:  P Ledochowitsch; A Yazdan-Shahmorad; K E Bouchard; C Diaz-Botia; T L Hanson; J-W He; B A Seybold; E Olivero; E A K Phillips; T J Blanche; C E Schreiner; A Hasenstaub; E F Chang; P N Sabes; M M Maharbiz
Journal:  J Neurosci Methods       Date:  2015-08-19       Impact factor: 2.390

4.  Complications of epidural spinal stimulation: lessons from the past and alternatives for the future.

Authors:  Giuliano Taccola; Sean Barber; Phillip J Horner; Humberto A Cerrel Bazo; Dimitry Sayenko
Journal:  Spinal Cord       Date:  2020-06-23       Impact factor: 2.772

5.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

6.  Decoding continuous limb movements from high-density epidural electrode arrays using custom spatial filters.

Authors:  A R Marathe; D M Taylor
Journal:  J Neural Eng       Date:  2013-04-23       Impact factor: 5.379

7.  A low-cost, multiplexed μECoG system for high-density recordings in freely moving rodents.

Authors:  Michele Insanally; Michael Trumpis; Charles Wang; Chia-Han Chiang; Virginia Woods; Kay Palopoli-Trojani; Silvia Bossi; Robert C Froemke; Jonathan Viventi
Journal:  J Neural Eng       Date:  2016-03-15       Impact factor: 5.379

8.  A hybrid PDMS-Parylene subdural multi-electrode array.

Authors:  Manuel Ochoa; Pinghung Wei; Andrew J Wolley; Kevin J Otto; Babak Ziaie
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

Review 9.  The Evolution of Neuroprosthetic Interfaces.

Authors:  Dayo O Adewole; Mijail D Serruya; James P Harris; Justin C Burrell; Dmitriy Petrov; H Isaac Chen; John A Wolf; D Kacy Cullen
Journal:  Crit Rev Biomed Eng       Date:  2016

10.  Simultaneous real-time monitoring of multiple cortical systems.

Authors:  Disha Gupta; N Jeremy Hill; Peter Brunner; Aysegul Gunduz; Anthony L Ritaccio; Gerwin Schalk
Journal:  J Neural Eng       Date:  2014-07-31       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.