Literature DB >> 23611833

Decoding continuous limb movements from high-density epidural electrode arrays using custom spatial filters.

A R Marathe1, D M Taylor.   

Abstract

OBJECTIVE: Our goal was to identify spatial filtering methods that would improve decoding of continuous arm movements from epidural field potentials as well as demonstrate the use of the epidural signals in a closed-loop brain-machine interface (BMI) system in monkeys. APPROACH: Eleven spatial filtering options were compared offline using field potentials collected from 64-channel high-density epidural arrays in monkeys. Arrays were placed over arm/hand motor cortex in which intracortical microelectrodes had previously been implanted and removed leaving focal cortical damage but no lasting motor deficits. Spatial filters tested included: no filtering, common average referencing (CAR), principle component analysis, and eight novel modifications of the common spatial pattern (CSP) algorithm. The spatial filtering method and decoder combination that performed the best offline was then used online where monkeys controlled cursor velocity using continuous wrist position decoded from epidural field potentials in real time. MAIN
RESULTS: Optimized CSP methods improved continuous wrist position decoding accuracy by 69% over CAR and by 80% compared to no filtering. Kalman decoders performed better than linear regression decoders and benefitted from including more spatially-filtered signals but not from pre-smoothing the calculated power spectra. Conversely, linear regression decoders required fewer spatially-filtered signals and were improved by pre-smoothing the power values. The 'position-to-velocity' transformation used during online control enabled the animals to generate smooth closed-loop movement trajectories using the somewhat limited position information available in the epidural signals. The monkeys' online performance significantly improved across days of closed-loop training. SIGNIFICANCE: Most published BMI studies that use electrocorticographic signals to decode continuous limb movements either use no spatial filtering or CAR. This study suggests a substantial improvement in decoding accuracy could be attained by using our new version of the CSP algorithm that extends the traditional CSP method for use with continuous limb movement data.

Entities:  

Mesh:

Year:  2013        PMID: 23611833      PMCID: PMC3746986          DOI: 10.1088/1741-2560/10/3/036015

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  87 in total

1.  Regularizing common spatial patterns to improve BCI designs: unified theory and new algorithms.

Authors:  Fabien Lotte; Cuntai Guan
Journal:  IEEE Trans Biomed Eng       Date:  2010-09-30       Impact factor: 4.538

2.  Toward synergy-based brain-machine interfaces.

Authors:  Ramana Vinjamuri; Douglas J Weber; Zhi-Hong Mao; Jennifer L Collinger; Alan D Degenhart; John W Kelly; Michael L Boninger; Elizabeth C Tyler-Kabara; Wei Wang
Journal:  IEEE Trans Inf Technol Biomed       Date:  2011-06-23

3.  Spatial filter selection for EEG-based communication.

Authors:  D J McFarland; L M McCane; S V David; J R Wolpaw
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1997-09

Review 4.  Toward electrocorticographic control of a dexterous upper limb prosthesis: building brain-machine interfaces.

Authors:  Matthew S Fifer; Soumyadipta Acharya; Heather L Benz; Mohsen Mollazadeh; Nathan E Crone; Nitish V Thakor
Journal:  IEEE Pulse       Date:  2012-01       Impact factor: 0.924

5.  Decoding position, velocity, or goal: does it matter for brain-machine interfaces?

Authors:  A R Marathe; D M Taylor
Journal:  J Neural Eng       Date:  2011-03-24       Impact factor: 5.379

6.  Combination of brain-computer interface training and goal-directed physical therapy in chronic stroke: a case report.

Authors:  Doris Broetz; Christoph Braun; Cornelia Weber; Surjo R Soekadar; Andrea Caria; Niels Birbaumer
Journal:  Neurorehabil Neural Repair       Date:  2010-06-02       Impact factor: 3.919

7.  Computer control using human intracortical local field potentials.

Authors:  Philip R Kennedy; M Todd Kirby; Melody M Moore; Brandon King; Adon Mallory
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-09       Impact factor: 3.802

8.  Cortical representation of ipsilateral arm movements in monkey and man.

Authors:  Karunesh Ganguly; Lavi Secundo; Gireeja Ranade; Amy Orsborn; Edward F Chang; Dragan F Dimitrov; Jonathan D Wallis; Nicholas M Barbaro; Robert T Knight; Jose M Carmena
Journal:  J Neurosci       Date:  2009-10-14       Impact factor: 6.167

9.  Electrocorticographically controlled brain-computer interfaces using motor and sensory imagery in patients with temporary subdural electrode implants. Report of four cases.

Authors:  Elizabeth A Felton; J Adam Wilson; Justin C Williams; P Charles Garell
Journal:  J Neurosurg       Date:  2007-03       Impact factor: 5.115

10.  Characterization of flexible ECoG electrode arrays for chronic recording in awake rats.

Authors:  John D Yeager; Derrick J Phillips; David M Rector; David F Bahr
Journal:  J Neurosci Methods       Date:  2008-07-03       Impact factor: 2.390

View more
  15 in total

1.  Decoding three-dimensional reaching movements using electrocorticographic signals in humans.

Authors:  David T Bundy; Mrinal Pahwa; Nicholas Szrama; Eric C Leuthardt
Journal:  J Neural Eng       Date:  2016-02-23       Impact factor: 5.379

2.  The impact of command signal power distribution, processing delays, and speed scaling on neurally-controlled devices.

Authors:  A R Marathe; D M Taylor
Journal:  J Neural Eng       Date:  2015-07-14       Impact factor: 5.379

Review 3.  Physiological properties of brain-machine interface input signals.

Authors:  Marc W Slutzky; Robert D Flint
Journal:  J Neurophysiol       Date:  2017-06-14       Impact factor: 2.714

4.  A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

Authors:  JingLe Jiang; Amar R Marathe; Jennifer C Keene; Dawn M Taylor
Journal:  J Neurosci Methods       Date:  2016-12-12       Impact factor: 2.390

5.  Characterisation and functional mapping of surface potentials in the rat dorsal column nuclei.

Authors:  Alastair J Loutit; Ted Maddess; Stephen J Redmond; John W Morley; Greg J Stuart; Jason R Potas
Journal:  J Physiol       Date:  2017-04-25       Impact factor: 5.182

6.  Continuous decoding of human grasp kinematics using epidural and subdural signals.

Authors:  Robert D Flint; Joshua M Rosenow; Matthew C Tate; Marc W Slutzky
Journal:  J Neural Eng       Date:  2016-11-30       Impact factor: 5.379

Review 7.  Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations.

Authors:  Marc W Slutzky
Journal:  Neuroscientist       Date:  2018-05-17       Impact factor: 7.519

8.  The effects of spatial filtering and artifacts on electrocorticographic signals.

Authors:  Y Liu; W G Coon; A de Pesters; P Brunner; G Schalk
Journal:  J Neural Eng       Date:  2015-08-13       Impact factor: 5.379

9.  Epidural electrocorticography for monitoring of arousal in locked-in state.

Authors:  Suzanne Martens; Michael Bensch; Sebastian Halder; Jeremy Hill; Femke Nijboer; Ander Ramos-Murguialday; Bernhard Schoelkopf; Niels Birbaumer; Alireza Gharabaghi
Journal:  Front Hum Neurosci       Date:  2014-10-21       Impact factor: 3.169

10.  Penalized Multi-Way Partial Least Squares for Smooth Trajectory Decoding from Electrocorticographic (ECoG) Recording.

Authors:  Andrey Eliseyev; Tetiana Aksenova
Journal:  PLoS One       Date:  2016-05-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.