Literature DB >> 20832379

Metal-on-metal bearings total hip arthroplasty: the cobalt and chromium ions release concern.

C Delaunay1, I Petit, I D Learmonth, P Oger, P A Vendittoli.   

Abstract

With certain concerns recently reported on metal-on-metal bearing couples in total hip arthroplasty, this study's objective is to review the current knowledge concerning release of metal ions and its potential consequences. Each metal-on-metal implant presents different tribological properties. The analytical techniques for metals are accurate and the Co ion rates seem acceptable up to 2 μg/L. A delayed type IV hypersensitivity reaction (atypical lymphocytic vasculitis-associated lesion [ALVAL]) may be the source of arthroplasty failure. Idiosyncratic, it remains unpredictable even using cutaneous tests and apparently is rare (0.3%). Today, there are no scientific or epidemiologic data supporting a risk of carcinogenesis or teratogenesis related to the use of a metal-on-metal bearings couple. Solid pseudotumors nearly exclusively are observed with resurfacing procedures, carrying a high annual revision rate in women under 40 years of age, occurring particularly in cases of acetabular malposition and with use of cast molded Cr-Co alloys. Osteolysis manifests through complete and progressive radiolucent lines or through cavitary lesions stemming from ALVAL-type alterations or impingement problems or implant incompatibility. The formation of wear debris exceeding the biological tolerance is possible with implant malposition, subluxation, and jamming of the femoral head in cases of cup deformity. Moreover, each implant presents different metal ion production; assessment of their performance and safety is required before their clinical use. With the knowledge available today, metal-on-metal bearing couples are contraindicated in cases of metal allergies or end stage renal dysfunction and small size resurfacing should cautiously be used.
Copyright © 2010. Published by Elsevier Masson SAS.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20832379     DOI: 10.1016/j.otsr.2010.05.008

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  31 in total

1.  Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.

Authors:  Christian P Delaunay; Sophie Putman; Benjamin Puliéro; Matthieu Bégin; Henri Migaud; François Bonnomet
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

2.  Biocompatibility and characterization of a Kolsterised(®) medical grade cobalt-chromium-molybdenum alloy.

Authors:  Malcolm Caligari Conti; Andreas Karl; Pierre Schembri Wismayer; Joseph Buhagiar
Journal:  Biomatter       Date:  2014-01-17

Review 3.  Mediators of the inflammatory response to joint replacement devices.

Authors:  Neil Cobelli; Brian Scharf; Giovanna M Crisi; John Hardin; Laura Santambrogio
Journal:  Nat Rev Rheumatol       Date:  2011-09-06       Impact factor: 20.543

Review 4.  Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues.

Authors:  Christoph H Lohmann; Gurpal Singh; Hans-Georg Willert; Gottfried H Buchhorn
Journal:  World J Orthop       Date:  2014-11-18

Review 5.  Hip resurfacing: a systematic review of literature.

Authors:  Régis Pailhé; Akash Sharma; Nicolas Reina; Etienne Cavaignac; Philippe Chiron; Jean-Michel Laffosse
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

6.  Metal ions activate vascular endothelial cells and increase lymphocyte chemotaxis and binding.

Authors:  James T Ninomiya; Scott A Kuzma; Timothy J Schnettler; John G Krolikowski; Janine A Struve; Dorothee Weihrauch
Journal:  J Orthop Res       Date:  2013-04-29       Impact factor: 3.494

Review 7.  [Results of 5 to 10-year follow-up after hip resurfacing. A systematic analysis of the literature on long-term results].

Authors:  M C M Klotz; S J Breusch; M Hassenpflug; R G Bitsch
Journal:  Orthopade       Date:  2012-06       Impact factor: 1.087

8.  Biomonitoring method for the analysis of chromium and cobalt in human whole blood using inductively coupled plasma - kinetic energy discrimination - mass spectrometry (ICP-KED-MS).

Authors:  Joaudimir Castro Georgi; Yuliya L Sommer; Cynthia D Ward; Po-Yung Cheng; Robert L Jones; Kathleen L Caldwell
Journal:  Anal Methods       Date:  2017-04-19       Impact factor: 2.896

9.  Biological responses of human mesenchymal stem cells to titanium wear debris particles.

Authors:  Hana Haleem-Smith; Evan Argintar; Curtis Bush; Daniel Hampton; William F Postma; Faye H Chen; Todd Rimington; Joshua Lamb; Rocky S Tuan
Journal:  J Orthop Res       Date:  2011-11-14       Impact factor: 3.494

Review 10.  Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates.

Authors:  S Sehatzadeh; K Kaulback; L Levin
Journal:  Ont Health Technol Assess Ser       Date:  2012-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.