BACKGROUND: The management of fractures of the distal radius continues to evolve. New operative strategies have recently been developed including the use of fixed-angle plates. This study reviews the results of 20 patients with fractures of the distal radius treated with a new multidirectional fixed angle plate. METHOD AND MATERIALS: A total of 20 patients with closed Colles type fractures of the distal radius were treated with Medartis (Aptus 2.5) palmar fixed-angle plates. Surgery was performed under plexus anesthesia using the standard or extended flexor carpi radialis (FCR) approach. Patients were evaluated prospectively with a mean follow-up of 26 weeks (range 23-28 weeks). Pain, range of motion, grip strength, DASH score, modified Mayo wrist score and radiographs were obtained. The level of significance was set at 95% and the χ(2) and ANOVA tests in combination with a post hoc Tukey test were used for statistical analysis.
RESULTS: The average range of motion (ROM) in extension-flexion was 87° (76% of the contralateral side) and in ulnar-radial deviation 42° (88% of the contralateral side). Pain values (visual analogue scale 0-100) at follow-up were 3 (without stress) and 24 (with stress). Grip strength improved to 84% of the contralateral side, the mean DASH score was 13 points and the modified Mayo wrist score confirmed the excellent results with a mean value of 83±27 points. Radiological examination showed a satisfactory result with an ulna variance of 0.9±0.4 mm, radio-ulnar inclination of 21±5° and palmar inclination of 4±6°.
CONCLUSIONS: Our data show that treating unstable distal radius fractures with multidirectional palmar fixed-angle plates is reliable and effective and produces good early functional and radiological results. However, long-term results with a larger number of patients and randomized prospective studies comparing this technique with other established procedures are required.

Entities:  

Mesh:

Year:  2010        PMID: 20830579     DOI: 10.1007/s00113-010-1845-1

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  28 in total

1.  Does Kapandji wiring help in older patients? A retrospective comparative review of displaced intra-articular distal radial fractures in patients over 55 years.

Authors:  T Board; A Kocialkowski; G Andrew
Journal:  Injury       Date:  1999-12       Impact factor: 2.586

2.  Percutaneous and limited open reduction of the articular surface of the distal radius.

Authors:  W B Geissler; D L Fernandez
Journal:  J Orthop Trauma       Date:  1991       Impact factor: 2.512

3.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

4.  [Multidirectional palmar fixed-angle plate fixation for unstable distal radius fracture].

Authors:  I Mehling; M Meier; U Schlör; H Krimmer
Journal:  Handchir Mikrochir Plast Chir       Date:  2007-02       Impact factor: 1.018

5.  Injectable calcium phosphate bone cement Norian SRS for the treatment of intra-articular compression fractures of the distal radius in osteoporotic women.

Authors:  Robert Zimmermann; Markus Gabl; Martin Lutz; Peter Angermann; Martin Gschwentner; Sigurd Pechlaner
Journal:  Arch Orthop Trauma Surg       Date:  2003-01-11       Impact factor: 3.067

6.  Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures.

Authors:  D Ring; J B Jupiter; J Brennwald; U Büchler; H Hastings
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

7.  Difficult wrist fractures. Perilunate fracture-dislocations of the wrist.

Authors:  W P Cooney; R Bussey; J H Dobyns; R L Linscheid
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

8.  [Palmar fixed angle plating systems for instable distal radius fractures].

Authors:  H Krimmer; C Pessenlehner; K Hasselbacher; M Meier; F Roth; R Meier
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

9.  Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results.

Authors:  Markus Figl; Patrick Weninger; Michael Liska; Marcus Hofbauer; Martin Leixnering
Journal:  Arch Orthop Trauma Surg       Date:  2009-02-19       Impact factor: 3.067

10.  Volar neutralization plate fixation of dorsally displaced distal radius fractures.

Authors:  Kostas J Constantine; Mark C Clawson; Peter J Stern
Journal:  Orthopedics       Date:  2002-02       Impact factor: 1.390

View more
  2 in total

1.  [Multidirectional locking volar plate in distal radius fractures. Secondary loss of reduction--correct implantation is essential].

Authors:  C Michelitsch; Y P Acklin; C Sommer
Journal:  Unfallchirurg       Date:  2013-12       Impact factor: 1.000

Review 2.  [Osteoporotic fractures of the distal radius. What is new?].

Authors:  J Meiners; C Jürgens; S Mägerlein; S Wallstabe; B Kienast; M Faschingbauer
Journal:  Chirurg       Date:  2012-10       Impact factor: 0.955

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.