Literature DB >> 11866144

Volar neutralization plate fixation of dorsally displaced distal radius fractures.

Kostas J Constantine1, Mark C Clawson, Peter J Stern.   

Abstract

Open reduction and volar neutralization plate fixation avoids problems associated with dorsal plate fixation (eg, extensor tenosynovitis and tendon rupture) and minimizes the necessity for secondary plate removal. Volar plating is a useful technique for treating dorsally displaced distal radius fractures with minimal scarring, infrequent bone grafting, and safe early wrist mobilization.

Entities:  

Mesh:

Year:  2002        PMID: 11866144     DOI: 10.3928/0147-7447-20020201-15

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  9 in total

1.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

2.  Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures.

Authors:  Santiago A Lozano-Calderón; Job N Doornberg; David Ring
Journal:  Hand (N Y)       Date:  2007-09-18

3.  Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: is there an advantage of palmar plates in the long term?

Authors:  Michael G Jakubietz; Joerg G Gruenert; Rafael G Jakubietz
Journal:  J Orthop Surg Res       Date:  2012-02-17       Impact factor: 2.359

4.  Plate fixation of distal radius fracture and related complications.

Authors:  Laurent Obert; Francois Loisel; Sonia Huard; Séverin Rochet; Daniel Lepage; Gregoire Leclerc; Patrick Garbuio
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-10-02

5.  [First results with a multidirectional fixed angle implant for internal fixation of distal radius fractures].

Authors:  R Meier; C Krettek; C Probst
Journal:  Unfallchirurg       Date:  2010-10       Impact factor: 1.000

Review 6.  [Osteoporotic fractures of the distal radius. What is new?].

Authors:  J Meiners; C Jürgens; S Mägerlein; S Wallstabe; B Kienast; M Faschingbauer
Journal:  Chirurg       Date:  2012-10       Impact factor: 0.955

7.  Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures.

Authors:  Marco Rizzo; Brian A Katt; Joshua T Carothers
Journal:  Hand (N Y)       Date:  2007-10-17

8.  Osteosynthesis of distal radius fractures with the Micronail.

Authors:  Raoul van Vugt; Ron W P M Geerts; Andries J Werre
Journal:  Eur J Trauma Emerg Surg       Date:  2010-03-23       Impact factor: 3.693

9.  Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes.

Authors:  Murat Çalbıyık; Deniz Ipek
Journal:  Med Sci Monit       Date:  2018-01-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.