Literature DB >> 16904528

Design of 4D treatment planning target volumes.

Eike Rietzel1, Arthur K Liu, Karen P Doppke, John A Wolfgang, Aileen B Chen, George T Y Chen, Noah C Choi.   

Abstract

PURPOSE: When using non-patient-specific treatment planning margins, respiratory motion may lead to geometric miss of the target while unnecessarily irradiating normal tissue. Imaging different respiratory states of a patient allows patient-specific target design. We used four-dimensional computed tomography (4DCT) to characterize tumor motion and create treatment volumes in 10 patients with lung cancer. These were compared with standard treatment volumes. METHODS AND MATERIALS: Four-dimensional CT and free breathing helical CT data of 10 patients were acquired. Gross target volumes (GTV) were delineated on the helical scan as well as on each phase of the 4D data. Composite GTVs were defined on 4DCT. Planning target volumes (PTV) including clinical target volume, internal margin (IM), and setup margin were generated. 4DPTVs with different IMs and standard PTVs were compared by computing centroid positions, volumes, volumetric overlap, and bounding boxes.
RESULTS: Four-dimensional PTVs and conventional PTVs differed in volume and centroid positions. Overlap between 4DPTVs generated from two extreme tumor positions only compared with 10 respiratory phases was 93.7%. Comparing PTVs with margins of 15 mm (IM 5 mm) on composite 4D target volumes to PTVs with 20 mm (IM 10 mm) on helical CT data resulted in a decrease in target volume sizes by 23% on average.
CONCLUSION: With patient-specific characterization of tumor motion, it should be possible to decrease internal margins. Patient-specific treatment volumes can be generated using extreme tumor positions on 4DCT. To date, more than 150 patients have been treated using 4D target design.

Entities:  

Mesh:

Year:  2006        PMID: 16904528     DOI: 10.1016/j.ijrobp.2006.05.024

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  42 in total

1.  Sequential dual-energy subtraction technique with a dynamic flat-panel detector (FPD): primary study for image-guided radiation therapy (IGRT).

Authors:  Rie Tanaka; Shigeru Sanada; Takeshi Matsui; Norio Hayashi; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2008-04-10

2.  Comparative evaluation of CT-based and PET/4DCT-based planning target volumes in the radiation of primary esophageal cancer.

Authors:  Yan-Luan Guo; Jian-Bin Li; Qian Shao; Yan-Kang Li; Peng Zhang
Journal:  Int J Clin Exp Med       Date:  2015-11-15

Review 3.  Magnetic resonance imaging in lung: a review of its potential for radiotherapy.

Authors:  Shivani Kumar; Gary Liney; Robba Rai; Lois Holloway; Daniel Moses; Shalini K Vinod
Journal:  Br J Radiol       Date:  2016-02-03       Impact factor: 3.039

4.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

5.  Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results.

Authors:  Luca Guerra; Sofia Meregalli; Alessandra Zorz; Rita Niespolo; Elena De Ponti; Federica Elisei; Sabrina Morzenti; Sarah Brenna; Andrea Crespi; Gianstefano Gardani; Cristina Messa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-01       Impact factor: 9.236

6.  Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system.

Authors:  S Mori; T Inaniwa; K Miki; T Shirai; K Noda
Journal:  Br J Radiol       Date:  2014-08-29       Impact factor: 3.039

7.  Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.

Authors:  Adam C Riegel; Moiz Ahmad; Xiaojun Sun; Tinsu Pan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Biological impact of geometric uncertainties: what margin is needed for intra-hepatic tumors?

Authors:  Hsiang-Chi Kuo; Wen-Shan Liu; Andrew Wu; Dennis Mah; Keh-Shih Chuang; Linda Hong; Ravi Yaparpalvi; Chandan Guha; Shalom Kalnicki
Journal:  Radiat Oncol       Date:  2010-06-03       Impact factor: 3.481

9.  Design and testing of a simulation framework for dosimetric motion studies integrating an anthropomorphic computational phantom into four-dimensional Monte Carlo.

Authors:  M Riboldi; G T Y Chen; G Baroni; H Paganetti; J Seco
Journal:  Technol Cancer Res Treat       Date:  2008-12

Review 10.  New era of radiotherapy: an update in radiation-induced lung disease.

Authors:  M F K Benveniste; J Welsh; M C B Godoy; S L Betancourt; O R Mawlawi; R F Munden
Journal:  Clin Radiol       Date:  2013-03-06       Impact factor: 2.350

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.