Investigation of scatter fractions for estimating leakage dose in medical X-ray imaging facilities.

Kimiya Noto1, Kichirou Koshida, Hiroji Iida, Tomoyuki Yamamoto, Ikuo Kobayashi, Chikako Kawabata.   

Abstract

It is essential to make accurate estimates of the scatter of radiation from the human body when calculating the leakage dose in medical X-ray imaging facilities. The scatter fraction varies with the size and shape of the radiation field in a way that is not exactly proportional to the area of the field. Japanese law quotes values for the scatter fraction that are provided by the National Council on Radiation Protection and Measurements, but these data were obtained 30 years ago, using equipment that differed considerably from that employed nowadays. To date, no attempt has been made to confirm whether these data accurately describe current Japanese equipment. In the present study, we used an ion chamber dosimeter to measure scattered radiation fractions, and new scatter factor data are presented that resolve these problems.

Entities:  

Mesh:

Year:  2009        PMID: 20821112     DOI: 10.1007/s12194-009-0057-2

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  11 in total

1.  Analysis of radiation scatter during angiographic procedures: evaluation of a phantom model and a modified radiation protection system.

Authors:  H Ito; T Hosoya; Y Eguchi; M Adachi; Y Watanabe; K Yamaguchi
Journal:  J Vasc Interv Radiol       Date:  1999 Nov-Dec       Impact factor: 3.464

2.  Scatter and transmission doses from several pediatric X-ray examinations in a nursery.

Authors:  John W Burrage; Peter L Rampant; Brendan P Beeson
Journal:  Pediatr Radiol       Date:  2003-07-12

3.  [Method of calculating side scatter factor for diagnostic X-rays].

Authors:  Hideki Kato
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2004-01

4.  A study of scatter in diagnostic X-ray rooms.

Authors:  G McVey; H Weatherburn
Journal:  Br J Radiol       Date:  2004-01       Impact factor: 3.039

5.  Measured scattered x-ray energy spectra for simulated irradiation geometries in diagnostic radiology.

Authors:  N W Marshall; K Faulkner; H Warren
Journal:  Med Phys       Date:  1996-07       Impact factor: 4.071

6.  Secondary shielding barriers for diagnostic x-ray facilities: scatter and leakage revisited.

Authors:  D J Simpkin; R L Dixon
Journal:  Health Phys       Date:  1998-03       Impact factor: 1.316

7.  Scattered radiation levels from a portable fluoroscopic/angiographic unit.

Authors:  C A Kelsey; J N King; W W Orrison; F A Mettler
Journal:  Health Phys       Date:  1989-11       Impact factor: 1.316

8.  Scattered radiation from a tissue-equivalent phantom for x rays from 50 to 300 kVp.

Authors:  E D Trout; J P Kelley
Journal:  Radiology       Date:  1972-07       Impact factor: 11.105

9.  The spectrum and angular distribution of x rays scattered from a water phantom.

Authors:  C W Cheng; K W Taylor; A F Holloway
Journal:  Med Phys       Date:  1995-08       Impact factor: 4.071

10.  On the primary barrier in diagnostic x-ray shielding.

Authors:  R L Dixon
Journal:  Med Phys       Date:  1994-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.