Right ventricular failure--a continuing problem in patients with left ventricular assist device support.

Ranjit John1, Sangjin Lee, Peter Eckman, Kenneth Liao.   

Abstract

The discrepancy between the limited availability of donor hearts and the ever-increasing number of patients with heart failure has led to the increasing use of left ventricular assist devices (LVAD) as a bridge to transplant. One of the main complications inherent following institution of LVAD therapy is right ventricular (RV) failure, manifested by the need for inotropic and/or nitric oxide support >14 days after LVAD implant and/or the need for right-sided mechanical circulatory support. RV failure is a major contributor of significant morbidity and mortality after LVAD placement. The complex pathophysiology of RV failure, which could potentially be related to RV myocardial dysfunction, interventricular dependence, and RV afterload, has led to inconsistencies in predicting risk factors for RV dysfunction. Several strategies have evolved over the years of experience with mechanical circulatory support that have aimed to avoid as well as reduce the incidence of RV failure. It is imperative that patients who definitely need biventricular support are identified. Despite the numerous risk factors identified in many studies as well as the development of risk factor profile scores, this continues to be a challenging problem. However, the lower incidence of RV failure following LVAD in the current era is encouraging, suggesting a favorable relationship between RV unloading and function, and continuous-flow physiology.

Entities:  

Mesh:

Year:  2010        PMID: 20811791     DOI: 10.1007/s12265-010-9216-4

Source DB:  PubMed          Journal:  J Cardiovasc Transl Res        ISSN: 1937-5387            Impact factor:   4.132


  41 in total

1.  Long-term use of a left ventricular assist device for end-stage heart failure.

Authors:  E A Rose; A C Gelijns; A J Moskowitz; D F Heitjan; L W Stevenson; W Dembitsky; J W Long; D D Ascheim; A R Tierney; R G Levitan; J T Watson; P Meier; N S Ronan; P A Shapiro; R M Lazar; L W Miller; L Gupta; O H Frazier; P Desvigne-Nickens; M C Oz; V L Poirier
Journal:  N Engl J Med       Date:  2001-11-15       Impact factor: 91.245

2.  Is severe right ventricular failure in left ventricular assist device recipients a risk factor for unsuccessful bridging to transplant and post-transplant mortality.

Authors:  Jeffrey A Morgan; Ranjit John; Brian J Lee; Mehmet C Oz; Yoshifumi Naka
Journal:  Ann Thorac Surg       Date:  2004-03       Impact factor: 4.330

3.  Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure.

Authors:  Nicholas C Dang; Veli K Topkara; Michelle Mercando; Joy Kay; Kurt H Kruger; Michael S Aboodi; Mehmet C Oz; Yoshifumi Naka
Journal:  J Heart Lung Transplant       Date:  2005-12-09       Impact factor: 10.247

4.  Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

Authors:  Nishant D Patel; Eric S Weiss; Justin Schaffer; Susan L Ullrich; Dennis C Rivard; Ashish S Shah; Stuart D Russell; John V Conte
Journal:  Ann Thorac Surg       Date:  2008-09       Impact factor: 4.330

5.  Changes in right ventricular function during continuous-flow left ventricular assist device support [corrected].

Authors:  Micha T Maeder; Angeline Leet; Andrew Ross; Donald Esmore; David M Kaye
Journal:  J Heart Lung Transplant       Date:  2009-04       Impact factor: 10.247

6.  Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.

Authors:  Ranjit John; Forum Kamdar; Kenneth Liao; Monica Colvin-Adams; Andrew Boyle; Lyle Joyce
Journal:  Ann Thorac Surg       Date:  2008-10       Impact factor: 4.330

7.  Risk factors predictive of right ventricular failure after left ventricular assist device implantation.

Authors:  Stavros G Drakos; Lindsay Janicki; Benjamin D Horne; Abdallah G Kfoury; Bruce B Reid; Stephen Clayson; Kenneth Horton; Francois Haddad; Dean Y Li; Dale G Renlund; Patrick W Fisher
Journal:  Am J Cardiol       Date:  2010-02-13       Impact factor: 2.778

8.  Preoperative and postoperative comparison of patients with univentricular and biventricular support with the thoratec ventricular assist device as a bridge to cardiac transplantation.

Authors:  D J Farrar; J D Hill; D G Pennington; L R McBride; W L Holman; R L Kormos; D Esmore; L A Gray; P E Seifert; G P Schoettle; C H Moore; P J Hendry; J N Bhayana
Journal:  J Thorac Cardiovasc Surg       Date:  1997-01       Impact factor: 5.209

Review 9.  Right heart interaction with the mechanically assisted left heart.

Authors:  D J Farrar; P G Compton; J J Hershon; J D Fonger; J D Hill
Journal:  World J Surg       Date:  1985-02       Impact factor: 3.352

10.  Right ventricular dysfunction and organ failure in left ventricular assist device recipients: a continuing problem.

Authors:  Minoo N Kavarana; Melissa S Pessin-Minsley; Jacqueline Urtecho; Katharine A Catanese; Margaret Flannery; Mehmet C Oz; Yoshifumi Naka
Journal:  Ann Thorac Surg       Date:  2002-03       Impact factor: 4.330

View more
  10 in total

Review 1.  Right ventricular strain as a novel approach to analyze right ventricular performance in patients with heart failure.

Authors:  Matteo Cameli; Francesca Maria Righini; Matteo Lisi; Sergio Mondillo
Journal:  Heart Fail Rev       Date:  2014-09       Impact factor: 4.214

2.  Right ventricular outflow tract systolic excursion: a useful method for determining right ventricular systolic function.

Authors:  Farhood Alsoos; Mohammad Almobarak; Hussam Shebli
Journal:  J Echocardiogr       Date:  2014-11-06

3.  Right ventricular free wall strain: a predictor of successful left ventricular assist device implantation.

Authors:  Maria Chiara Todaro; Giuseppe Romano; Scipione Carerj; Francesco Clemenza; Michele Pilato; Bijoy K Khandheria
Journal:  Tex Heart Inst J       Date:  2015-02-01

4.  Right Ventricular Fiber Structure as a Compensatory Mechanism in Pressure Overload: A Computational Study.

Authors:  Arnold D Gomez; Huashan Zou; Megan E Bowen; Xiaoqing Liu; Edward W Hsu; Stephen H McKellar
Journal:  J Biomech Eng       Date:  2017-08-01       Impact factor: 2.097

5.  Development of a Double-Lumen Cannula for a Percutaneous RVAD.

Authors:  Dongfang Wang; Cameron Jones; Cherry Ballard-Croft; Ju Zhao; Guangfeng Zhao; Stephen Topaz; Joseph B Zwischenberger
Journal:  ASAIO J       Date:  2015 Jul-Aug       Impact factor: 2.872

Review 6.  The practical role of echocardiography in selection, implantation, and management of patients requiring LVAD therapy.

Authors:  Maria Chiara Todaro; Bijoy K Khandheria; Timothy E Paterick; Matt M Umland; Vinay Thohan
Journal:  Curr Cardiol Rep       Date:  2014-04       Impact factor: 2.931

7.  Rotary mechanical circulatory support systems.

Authors:  Milad Hosseinipour; Rajesh Gupta; Mark Bonnell; Mohammad Elahinia
Journal:  J Rehabil Assist Technol Eng       Date:  2017-09-01

Review 8.  Right ventricular failure after left ventricular assist device implantation: a review of the literature.

Authors:  Valeria Lo Coco; Maria Elena De Piero; Giulio Massimi; Giovanni Chiarini; Giuseppe M Raffa; Mariusz Kowalewski; Jos Maessen; Roberto Lorusso
Journal:  J Thorac Dis       Date:  2021-02       Impact factor: 2.895

9.  Management and outcome of patients supported with Impella 5.0 for refractory cardiogenic shock.

Authors:  Philippe Gaudard; Marc Mourad; Jacob Eliet; Norddine Zeroual; Geraldine Culas; Philippe Rouvière; Bernard Albat; Pascal Colson
Journal:  Crit Care       Date:  2015-10-09       Impact factor: 9.097

10.  Association of preoperative duration of inotropy on prevalence of right ventricular failure following LVAD implantation.

Authors:  Mina M Benjamin; Sakthi Sundararajan; Samian Sulaiman; Bryan Miles; Rebekah J Walker; Lucian Durham; Takushi Kohmoto; David L Joyce; David Ishizawar; Nunzio Gaglianello; Asim Mohammed
Journal:  ESC Heart Fail       Date:  2020-06-11
  10 in total