Literature DB >> 19332263

Changes in right ventricular function during continuous-flow left ventricular assist device support [corrected].

Micha T Maeder1, Angeline Leet, Andrew Ross, Donald Esmore, David M Kaye.   

Abstract

BACKGROUND: Studies in explanted hearts from patients supported with a left ventricular assist device (LVAD) suggest that no or a less pronounced reverse remodeling process occurs in the right ventricle (RV) during LVAD support. The intermediate-term functional changes in RV function in patients with refractory heart failure (HF) supported with a continuous LVAD are not well characterized.
METHODS: Serial transthoracic echocardiograms and simultaneous measurements of biochemical surrogates of disease severity and organ perfusion were obtained in 20 patients (aged 57 +/- 17 years) with refractory HF before and after implantation of a continuous-flow LVAD (VentrAssist, Ventracor Ltd, Chatswood, Australia).
RESULTS: After a median (interquartile range) follow-up of 140 days (34-367 days), RV diameter was reduced (36 +/- 7 vs 33 +/- 4 mm; p = 0.04), as was right atrial area (27 +/- 5 vs 24 +/- 6 cm(2); p = .04). There was a trend toward a reduction in tricuspid annulus plane systolic excursion (14 +/- 6 vs 13 +/- 5 mm; p = .05). RV fractional area change (26% +/- 13% vs 27% +/- 10%; p = .53) and global RV dysfunction graded visually using a scale from 0 (absent) to 3 (severe dysfunction) did not change from pre-implant to follow-up (2 [1-2] vs 1.5 [0.5-2]; p = .18). The degree of global RV dysfunction at follow-up was closely related to the degree of RV dysfunction at the pre-implant study (r = 0.69; p = .001). Changes in global RV dysfunction were inversely related to changes in glomerular filtration rate (r = -0.49; p = .03).
CONCLUSIONS: During continuous-flow LVAD support, pre-existing RV dysfunction does not worsen in the intermediate term.

Entities:  

Mesh:

Year:  2009        PMID: 19332263     DOI: 10.1016/j.healun.2009.01.007

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  17 in total

Review 1.  Right ventricular strain as a novel approach to analyze right ventricular performance in patients with heart failure.

Authors:  Matteo Cameli; Francesca Maria Righini; Matteo Lisi; Sergio Mondillo
Journal:  Heart Fail Rev       Date:  2014-09       Impact factor: 4.214

Review 2.  Right side of heart failure.

Authors:  Maya Guglin; Sameer Verma
Journal:  Heart Fail Rev       Date:  2012-05       Impact factor: 4.214

Review 3.  Right ventricular failure--a continuing problem in patients with left ventricular assist device support.

Authors:  Ranjit John; Sangjin Lee; Peter Eckman; Kenneth Liao
Journal:  J Cardiovasc Transl Res       Date:  2010-09-01       Impact factor: 4.132

4.  Right ventricular dysfunction during intensive pharmacologic unloading persists after mechanical unloading.

Authors:  Maryse Palardy; Anju Nohria; Jose Rivero; Neal Lakdawala; Patricia Campbell; Mahoto Kato; Leslie M Griffin; Colleen M Smith; Gregory S Couper; Lynne W Stevenson; Michael M Givertz
Journal:  J Card Fail       Date:  2009-12-11       Impact factor: 5.712

5.  Diagnosis and management of right-sided heart failure in subjects supported with left ventricular assist devices.

Authors:  Matthew A Romano; Jennifer Cowger; Keith D Aaronson; Francis D Pagani
Journal:  Curr Treat Options Cardiovasc Med       Date:  2010-10

Review 6.  Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device.

Authors:  Gautam Ramani; Wengen Chen; Sonika Patel; Jean Judy; Van-Khue Ton
Journal:  Curr Cardiol Rep       Date:  2019-07-05       Impact factor: 2.931

Review 7.  Physiologic effects of continuous-flow left ventricular assist devices.

Authors:  Aaron H Healy; Stephen H McKellar; Stavros G Drakos; Antigoni Koliopoulou; Josef Stehlik; Craig H Selzman
Journal:  J Surg Res       Date:  2016-01-20       Impact factor: 2.192

8.  Right ventricular dysfunction following continuous flow left ventricular assist device placement in 51 patients: predicators and outcomes.

Authors:  Siyamek Neragi-Miandoab; Daniel Goldstein; Ricardo Bello; Robert Michler; David D'Alessandro
Journal:  J Cardiothorac Surg       Date:  2012-06-27       Impact factor: 1.637

9.  Right ventricular plasticity and functional imaging.

Authors:  Evan L Brittain; Anna R Hemnes; Mary Keebler; Mark Lawson; Benjamin F Byrd; Tom Disalvo
Journal:  Pulm Circ       Date:  2012-07       Impact factor: 3.017

10.  A mock circulatory system to assess the performance of continuous-flow left ventricular assist devices (LVADs): does axial flow unload better than centrifugal LVAD?

Authors:  Thomas Sénage; Dorothée Février; Magali Michel; Emmanuel Pichot; Daniel Duveau; Steven Tsui; Jean Noel Trochu; Jean Christian Roussel
Journal:  ASAIO J       Date:  2014 Mar-Apr       Impact factor: 2.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.