Literature DB >> 20799034

Coronary endothelial function: a clinical role for PET?

Riemer H J A Slart.   

Abstract

Entities:  

Mesh:

Year:  2010        PMID: 20799034      PMCID: PMC2975915          DOI: 10.1007/s00259-010-1591-1

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


× No keyword cloud information.
Coronary endothelial dysfunction is the earliest abnormality in the development of coronary atherosclerosis and is also independently associated with future cardiac events. Quantification of myocardial blood flow (MBF) can assist in the diagnosis of diffuse coronary artery disease (CAD), heart failure and microvascular disease [1, 2]. In the absence of coronary stenoses, a reduced coronary flow reserve (CFR) reflects dysfunction of the coronary microcirculation. Positron emission tomography (PET) plays an important role in the assessment of MBF due to four major characteristics: (1) high sensitivity, (2) excellent temporal resolution, (3) the possibility to label molecules without altering their chemical properties and (4) the short half-life of isotopes. The most common method of quantifying MBF involves the acquisition of dynamic images with the cyclotron-produced radiopharmaceuticals 13N-ammonia and 15O-water. An alternative method is the generator-produced 82Rb. In this issue of the European Journal of Nuclear Medicine and Molecular Imaging, Yoshinaga and colleagues present some interesting data comparing the quantitative analysis of coronary endothelial function with 82Rb and 15O-water PET [3]. MBF was assessed at rest and during a cold pressor test (CPT) with 82Rb and 15O-water PET in controls and smokers. They found a reduced CPT to rest ratio in smokers compared with controls for both radiopharmaceuticals. They concluded that 82Rb is a reliable method in comparison to 15O-water PET and that 82Rb may be applicable for risk assessment in subjects with coronary risk factors. The usefulness of 82Rb is proven in this study; however, the study included in total 19 subjects, and there will be a need for studies with larger sample sizes. A wide pallet of pathological disorders like hyperlipidaemia, hypertension, diabetes and smoking attenuate the vasomotor response to NO and reveals the widespread distribution of underlying causes that can result in endothelial dysfunction. In other words, MBF assessment provides a way to document how risk factors translate into measurable damage to the coronary circulation. In my opinion, it is time to get MBF PET ready for the future, because of the open access to 82Rb now in Europe. The use of 82Rb would give advantages compared to 13N-ammonia and 15O-water PET: no need for a cyclotron, 24-h/day access, fast acquisition protocols allowing high throughput, evaluation of stunning by using rest and stress gating modality and a better visual quality compared to 15O-water. Also absolute quantification of MBF is possible with 82Rb and validated [4, 5] and the important parameter of CFR for prognosis can be calculated [6]. Due to the wide range of the 82Rb positron, the resolution is reduced. An important issue of concern is the cost-effectiveness of 82Rb, especially compared to the widely used SPECT technique. The 82Rb generator needs to be replaced every 4–6 weeks, rendering this technique relatively expensive, with a price in the region of 25,000 euros. Industry should put maximal effort into reducing the price of the generator, so that 82Rb may finally facilitate a breakthrough of cardiac PET myocardial perfusion imaging (MPI) for routine clinical practice in Europe. The first studies on the clinical utility of 82Rb MPI were reported almost 25 years ago [7], and accurate data of 82Rb MPI are available in the literature linked to outcomes [8, 9]. Although 82Rb is now widely available in the USA, this tracer is moderately available in Europe; however, a dawn is coming. Industrial 82Rb supply for Europe is growing and may lead to a wider implementation of 82Rb. Nevertheless, and although the use of 82Rb has been already described in a number of reports in the literature, the merit of the present study is that it encourages us to benefit from the substantial superiority of the PET technique for instance over SPECT, resulting in good image quality even in obese patients. The superiority over SPECT can be expected regarding accuracy, study duration, staff radiation exposure, reduced patient dose, patient discomfort and potentially economic benefit. These are all important implications, which may not have been fully appreciated in Europe so far. A clinical role of MBF PET should be highlighted now, because of the easier access to 82Rb.
  7 in total

1.  What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography?

Authors:  Keiichiro Yoshinaga; Benjamin J W Chow; Kathryn Williams; Li Chen; Robert A deKemp; Linda Garrard; Alexander Lok-Tin Szeto; May Aung; Ross A Davies; Terrence D Ruddy; Rob S B Beanlands
Journal:  J Am Coll Cardiol       Date:  2006-08-17       Impact factor: 24.094

2.  Reduced regional myocardial perfusion reserve is associated with impaired contractile performance in idiopathic dilated cardiomyopathy.

Authors:  R A Tio; R H J A Slart; R A de Boer; P A van der Vleuten; R M de Jong; L M van Wijk; T Willems; D D Lubbers; A A Voors; D J van Veldhuisen
Journal:  Neth Heart J       Date:  2009-12       Impact factor: 2.380

3.  Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF.

Authors:  Sharmila Dorbala; Rory Hachamovitch; Zelmira Curillova; Deepak Thomas; Divya Vangala; Raymond Y Kwong; Marcelo F Di Carli
Journal:  JACC Cardiovasc Imaging       Date:  2009-07

4.  Quantification of regional myocardial blood flow in a canine model of stunned and infarcted myocardium: comparison of rubidium-82 positron emission tomography with microspheres.

Authors:  Katie S Lekx; Robert A deKemp; Robert S B Beanlands; Gerald Wisenberg; R Glenn Wells; Robert Z Stodilka; Mireille Lortie; Ran Klein; Pamela Zabel; Michael S Kovacs; Jane Sykes; Frank S Prato
Journal:  Nucl Med Commun       Date:  2010-01       Impact factor: 1.690

5.  Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82.

Authors:  K L Gould; R A Goldstein; N A Mullani; R L Kirkeeide; W H Wong; T J Tewson; M S Berridge; L A Bolomey; R K Hartz; R W Smalling
Journal:  J Am Coll Cardiol       Date:  1986-04       Impact factor: 24.094

6.  Quantification of myocardial blood flow with 82Rb dynamic PET imaging.

Authors:  Mireille Lortie; Rob S B Beanlands; Keiichiro Yoshinaga; Ran Klein; Jean N Dasilva; Robert A DeKemp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07-07       Impact factor: 9.236

7.  Comparison between the prognostic value of left ventricular function and myocardial perfusion reserve in patients with ischemic heart disease.

Authors:  René A Tio; Ali Dabeshlim; Hans-Marc J Siebelink; Johan de Sutter; Hans L Hillege; Clark J Zeebregts; Rudi A J O Dierckx; Dirk J van Veldhuisen; Felix Zijlstra; Riemer H J A Slart
Journal:  J Nucl Med       Date:  2009-01-21       Impact factor: 10.057

  7 in total
  1 in total

Review 1.  Assessment of coronary endothelial function using PET.

Authors:  Keiichiro Yoshinaga; Osamu Manabe; Nagara Tamaki
Journal:  J Nucl Cardiol       Date:  2011-05       Impact factor: 5.952

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.