Reference-based linear curve fitting for bolus arrival time estimation in 4D MRA and MR perfusion-weighted image sequences.

Nils Daniel Forkert1, Jens Fiehler, Thorsten Ries, Till Illies, Dietmar Möller, Heinz Handels, Dennis Säring.   

Abstract

The bolus arrival time (BAT) based on an indicator dilution curve is an important hemodynamic parameter. As the direct estimation of this parameter is generally problematic, various parametric models have been proposed that describe typical physiological shapes of indicator dilution curves, but it remains unclear which model describes the real physiological background. This article presents a method that indirectly incorporates physiological information derived from the data available. For this, a patient-specific hemodynamic reference curve is extracted, and the corresponding reference BAT is determined. To estimate a BAT for a given signal curve, the reference curve is fitted linearly to the signal curve. The parameters of the fitting process are then used to transfer the reference BAT to the signal curve. The validation of the method proposed based on Monte Carlo simulations showed that the approach presented is capable of improving the BAT estimation precision compared with standard BAT estimation methods by up to 59% while at the same time reduces the computation time. A major benefit of the method proposed is that no assumption about the underlying distribution of indicator dilution has to be made, as it is implicitly modeled in the reference curve.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20740654     DOI: 10.1002/mrm.22583

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Analysis of the influence of 4D MR angiography temporal resolution on time-to-peak estimation error for different cerebral vessel structures.

Authors:  N D Forkert; T Illies; D Möller; H Handels; D Säring; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

2.  Intranidal signal distribution in post-contrast time-of-flight MRA is associated with rupture risk factors in arteriovenous malformations.

Authors:  N D Forkert; J Fiehler; M Schönfeld; J Sedlacik; J Regelsberger; H Handels; T Illies
Journal:  Clin Neuroradiol       Date:  2012-08-26       Impact factor: 3.649

3.  Classification of cerebral arteriovenous malformations and intranidal flow patterns by color-encoded 4D-hybrid-MRA.

Authors:  T Illies; N D Forkert; T Ries; J Regelsberger; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-09       Impact factor: 3.825

4.  Comparison of 10 TTP and Tmax estimation techniques for MR perfusion-diffusion mismatch quantification in acute stroke.

Authors:  N D Forkert; P Kaesemann; A Treszl; S Siemonsen; B Cheng; H Handels; J Fiehler; G Thomalla
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-28       Impact factor: 3.825

5.  Bolus arrival time and its effect on tissue characterization with dynamic contrast-enhanced magnetic resonance imaging.

Authors:  Alireza Mehrtash; Sandeep N Gupta; Dattesh Shanbhag; James V Miller; Tina Kapur; Fiona M Fennessy; Ron Kikinis; Andriy Fedorov
Journal:  J Med Imaging (Bellingham)       Date:  2016-03-01

6.  Correlation-based perfusion mapping using time-resolved MR angiography: A feasibility study for patients with suspicions of steno-occlusive craniocervical arteries.

Authors:  Yoonho Nam; Jinhee Jang; Sonya Youngju Park; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Bum-Soo Kim
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

7.  Computer-aided nidus segmentation and angiographic characterization of arteriovenous malformations.

Authors:  Nils Daniel Forkert; Till Illies; Einar Goebell; Jens Fiehler; Dennis Säring; Heinz Handels
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-03-07       Impact factor: 2.924

8.  Cerebral Hemodynamics in Patients with Hemolytic Uremic Syndrome Assessed by Susceptibility Weighted Imaging and Four-Dimensional Non-Contrast MR Angiography.

Authors:  Ulrike Löbel; Nils Daniel Forkert; Peter Schmitt; Thorsten Dohrmann; Maria Schroeder; Tim Magnus; Stefan Kluge; Christina Weiler-Normann; Xiaoming Bi; Jens Fiehler; Jan Sedlacik
Journal:  PLoS One       Date:  2016-11-01       Impact factor: 3.240

9.  Optimal Scaling Approaches for Perfusion MRI with Distorted Arterial Input Function (AIF) in Patients with Ischemic Stroke.

Authors:  Sukhdeep Singh Bal; Fan Pei Gloria Yang; Yueh-Feng Sung; Ke Chen; Jiu-Haw Yin; Giia-Sheun Peng
Journal:  Brain Sci       Date:  2022-01-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.