Literature DB >> 20738324

Intraocular lens alignment from purkinje and Scheimpflug imaging.

Patricia Rosales1, Alberto De Castro, Ignacio Jiménez-Alfaro, Susana Marcos.   

Abstract

The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system images the reflections of an oblique collimated light source on the anterior cornea and anterior and posterior IOL surfaces and relies on the well supported assumption of the linearity of the Purkinje images with respect to IOL tilt and decentration. Scheimpflug imaging requires geometrical distortion correction and image processing techniques to retrieve the pupillary axis, IOL axis and pupil centre from the three-dimensional anterior segment image of the eye. Validation of the techniques using a physical eye model indicates that IOL tilt is estimated within an accuracy of 0.261 degree and decentration within 0.161 mm. Measurements on patients implanted with aspheric IOLs indicate that IOL tilt and decentration tend to be mirror symmetric between left and right eyes. The average tilt was 1.54 degrees and the average decentration was 0.21 mm. Simulated aberration patterns using custom models of the patients eyes, built using anatomical data of the anterior cornea and foveal position, the IOL geometry and the measured IOL tilt and decentration predict the experimental wave aberrations measured using laser ray tracing aberrometry on the same eyes. This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye.

Entities:  

Mesh:

Year:  2010        PMID: 20738324     DOI: 10.1111/j.1444-0938.2010.00514.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  17 in total

1.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

3.  Reinforced scleral fixation of foldable intraocular lens by double sutures: comparison with intrascleral intraocular lens fixation.

Authors:  Yodpong Chantarasorn; Settapong Techalertsuwan; Pongsavit Siripanthong; Anurak Tamerug
Journal:  Jpn J Ophthalmol       Date:  2018-02-20       Impact factor: 2.447

4.  Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery.

Authors:  Michael Burgmüller; Kata Mihaltz; Christopher Schütze; Bernhard Angermann; Veronika Vécsei-Marlovits
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-10-01       Impact factor: 3.117

5.  Interfaces detection after corneal refractive surgery by low coherence optical interferometry.

Authors:  I Verrier; C Veillas; T Lépine; F Nguyen; G Thuret; P Gain
Journal:  Biomed Opt Express       Date:  2010-11-19       Impact factor: 3.732

6.  Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.

Authors:  Takashi Fujikado; Makoto Saika
Journal:  Clin Ophthalmol       Date:  2014-11-28

7.  Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial.

Authors:  Xiaojian Zhong; Erping Long; Wan Chen; Wu Xiang; Zhaochuan Liu; Hui Chen; Jingjing Chen; Zhuoling Lin; Haotian Lin; Weirong Chen
Journal:  BMC Ophthalmol       Date:  2016-07-08       Impact factor: 2.209

8.  Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy.

Authors:  Shasha Gao; Tingyu Qin; Shengnan Wang; Yong Lu
Journal:  J Ophthalmol       Date:  2015-08-30       Impact factor: 1.909

Review 9.  Angle Kappa and its importance in refractive surgery.

Authors:  Majid Moshirfar; Ryan N Hoggan; Valliammai Muthappan
Journal:  Oman J Ophthalmol       Date:  2013-09

10.  Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses.

Authors:  Michael Lasta; Kata Miháltz; Illés Kovács; Pia Veronika Vécsei-Marlovits
Journal:  J Ophthalmol       Date:  2017-08-16       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.