Literature DB >> 20736499

Modeling the detectability of vesicoureteral reflux using microwave radiometry.

Kavitha Arunachalam1, Paolo F Maccarini, Valeria De Luca, Fernando Bardati, Brent W Snow, Paul R Stauffer.   

Abstract

We present the modeling efforts on antenna design, frequency selection and receiver sensitivity estimation to detect vesicoureteral reflux (VUR) using microwave (MW) radiometry as warm urine from the bladder maintained at fever range temperature using a MW hyperthermia device reflows into the kidneys. The radiometer center frequency (f(c)), frequency band (Deltaf) and aperture radius (r(a)) of the physical antenna for kidney temperature monitoring are determined using a simplified universal antenna model with a circular aperture. Anatomical information extracted from the computed tomography (CT) images of children aged 4-6 years is used to construct a layered 3D tissue model. Radiometric antenna efficiency is evaluated in terms of the ratio of the power collected from the target at depth to the total power received by the antenna (eta). The power ratio of the theoretical antenna is used to design a microstrip log spiral antenna with directional radiation pattern over f(c) +/- Deltaf/2. Power received by the log spiral from the deep target is enhanced using a thin low-loss dielectric matching layer. A cylindrical metal cup is proposed to shield the antenna from electromagnetic interference (EMI). Transient thermal simulations are carried out to determine the minimum detectable change in the antenna brightness temperature (deltaT(B)) for 15-25 mL urine refluxes at 40-42 degrees C located 35 mm from the skin surface. Theoretical antenna simulations indicate maximum eta over 1.1-1.6 GHz for r(a) = 30-40 mm. Simulations of the 35 mm radius tapered log spiral yielded a higher power ratio over f(c) +/- Deltaf/2 for the 35-40 mm deep targets in the presence of an optimal matching layer. Radiometric temperature calculations indicate deltaT(B) 0.1 K for the 15 mL urine at 40 degrees C and 35 mm depth. Higher eta and deltaT(B) were observed for the antenna and matching layer inside the metal cup. Reflection measurements of the log spiral in a saline phantom are in agreement with the simulation data. The numerical study suggests that a radiometer with f(c) = 1.35 GHz, Deltaf = 500 MHz and detector sensitivity better than 0.1 K would be the appropriate tool to noninvasively detect VUR using the log spiral antenna.

Entities:  

Mesh:

Year:  2010        PMID: 20736499      PMCID: PMC2972589          DOI: 10.1088/0031-9155/55/18/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  An efficient, accurate and robust radiometer configuration for microwave temperature measurement for industrial and medical applications.

Authors:  D V Land
Journal:  J Microw Power Electromagn Energy       Date:  2001       Impact factor: 1.325

2.  Improved detectability in medical microwave radio-thermometers as obtained by active antennas.

Authors:  Svein Jacobsen; Øystein Klemetsen
Journal:  IEEE Trans Biomed Eng       Date:  2008-12       Impact factor: 4.538

3.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

4.  Monitoring of deep brain temperature in infants using multi-frequency microwave radiometry and thermal modelling.

Authors:  J W Han; G M Van Leeuwen; S Mizushina; J B Van de Kamer; K Maruyama; T Sugiura; D V Azzopardi; A D Edwards
Journal:  Phys Med Biol       Date:  2001-07       Impact factor: 3.609

5.  The significance of accurate dielectric tissue data for hyperthermia treatment planning.

Authors:  J B Van de Kamer; N Van Wieringen; A A De Leeuw; J J Lagendijk
Journal:  Int J Hyperthermia       Date:  2001 Mar-Apr       Impact factor: 3.914

6.  Microwave thermochemotherapy in the treatment of the bladder carcinoma--electromagnetic and dielectric studies--clinical protocol.

Authors:  A Dietsch; J C Camart; J P Sozanski; B Prevost; B Mauroy; M Chivé
Journal:  IEEE Trans Biomed Eng       Date:  2000-05       Impact factor: 4.538

Review 7.  What is the normal prevalence of vesicoureteral reflux?

Authors:  M A Sargent
Journal:  Pediatr Radiol       Date:  2000-09

8.  Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease.

Authors:  S Jacobsen; P R Stauffer; D G Neuman
Journal:  IEEE Trans Biomed Eng       Date:  2000-11       Impact factor: 4.538

9.  Vesicoureteral reflux grading in contrast-enhanced voiding urosonography.

Authors:  Kassa Darge; Jochen Troeger
Journal:  Eur J Radiol       Date:  2002-08       Impact factor: 3.528

10.  Risk factors for urinary tract infection after dextranomer/hyaluronic acid endoscopic injection.

Authors:  Erica Traxel; William DeFoor; Pramod Reddy; Curtis Sheldon; Eugene Minevich
Journal:  J Urol       Date:  2009-08-18       Impact factor: 7.450

View more
  14 in total

1.  Stable Microwave Radiometry System for Long Term Monitoring of Deep Tissue Temperature.

Authors:  Paul R Stauffer; Dario B Rodriques; Sara Salahi; Erdem Topsakal; Tiago R Oliveira; Aniruddh Prakash; Fabio D'Isidoro; Douglas Reudink; Brent W Snow; Paolo F Maccarini
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-02-26

2.  Design and optimization of an ultra wideband and compact microwave antenna for radiometric monitoring of brain temperature.

Authors:  Dario B Rodrigues; Paolo F Maccarini; Sara Salahi; Tiago R Oliveira; Pedro J S Pereira; Paulo Limao-Vieira; Brent W Snow; Doug Reudink; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2014-04-15       Impact factor: 4.538

Review 3.  Imaging-based internal body temperature measurements: The journal Temperature toolbox.

Authors:  Juho Raiko; Kalle Koskensalo; Teija Sainio
Journal:  Temperature (Austin)       Date:  2020-05-29

4.  The effect of using a dielectric matching medium in focused microwave radiometry: an anatomically detailed head model study.

Authors:  Maria Koutsoupidou; Evangelos Groumpas; Irene S Karanasiou; Maria Christopoulou; Konstantina Nikita; Nikolaos Uzunoglu
Journal:  Med Biol Eng Comput       Date:  2017-10-13       Impact factor: 2.602

5.  Measurement of Brown Adipose Tissue Activity Using Microwave Radiometry and 18F-FDG PET/CT.

Authors:  John P Crandall; Joo H O; Prateek Gajwani; Jeffrey P Leal; Daniel D Mawhinney; Fred Sterzer; Richard L Wahl
Journal:  J Nucl Med       Date:  2018-02-09       Impact factor: 10.057

6.  Non-invasive vesicoureteral reflux detection: heating risk studies for a new device.

Authors:  B W Snow; K Arunachalam; V De Luca; P F Maccarini; O Klemetsen; Y Birkelund; T J Pysher; P R Stauffer
Journal:  J Pediatr Urol       Date:  2011-06-12       Impact factor: 1.830

7.  Detection of vesicoureteral reflux using microwave radiometry-system characterization with tissue phantoms.

Authors:  Kavitha Arunachalam; Paolo Maccarini; Valeria De Luca; Piero Tognolatti; Fernando Bardati; Brent Snow; Paul Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2011-01-20       Impact factor: 4.538

8.  Dielectric properties measurements of brown and white adipose tissue in rats from 0.5 to 10 GHz.

Authors:  D B Rodrigues; P R Stauffer; E Colebeck; A Z Hood; S Salahi; P F Maccarini; E Topsakal
Journal:  Biomed Phys Eng Express       Date:  2016-03-22

9.  EVOLUTION OF ANTENNA PERFORMANCE FOR APPLICATIONS IN THERMAL MEDICNE.

Authors:  P R Stauffer; P F Maccarini
Journal:  Proc Eur Conf Antennas Propag       Date:  2011

10.  Non-invasive measurement of brain temperature with microwave radiometry: demonstration in a head phantom and clinical case.

Authors:  Paul R Stauffer; Brent W Snow; Dario B Rodrigues; Sara Salahi; Tiago R Oliveira; Doug Reudink; Paolo F Maccarini
Journal:  Neuroradiol J       Date:  2014-02-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.