Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone.

Stefan Unger1, Unger Stefan, Michael Blauth, Blauth Michael, Werner Schmoelz, Schmoelz Werner.   

Abstract

BACKGROUND AND
PURPOSE: In the development of new strategies for fracture fixation, new methods have to be tested biomechanically under in vitro conditions before clinical trials can be performed. The gold standard for laboratory evaluations is fresh-frozen specimen. As the availability of fresh-frozen specimens is limited and since their use bears infectious risks, specimens treated with various chemical embalming fluids are also used. These preservation methods may alter the mechanical properties of the specimens used. Therefore, the aims of the present study were to determine the effects of three different preservation methods (formalin fixation (FO), Thiel-fixation (TH), and alcohol-glycerine fixation (AG)) on the elastic and postyield mechanical properties of cortical bone and to compare these properties to those of fresh-frozen (FF) specimens.
MATERIALS AND METHODS: Cylindrical cortical specimens (diameter 3mm, length 60 mm) were obtained from human femurs (n=48) and bovine tibiae (n=40). Before specimen immersion in different fixation fluids, bone mineral density (BMD) as well as the initial Young's modulus was determined. The Young's modulus was determined in a nondestructive bending test, and measurements were repeated after 6 months of immersion in fixative solution. Subsequent to the nondestructive test, a destructive 3-point bending test was conducted to assess the postyield and fracture properties.
RESULTS: The BMD as well as the initial Young's modulus showed no significant differences between the four test groups. After 6 months in fixative solution, the Young's modulus was significantly lowered in human Thiel specimens and only showed minor changes in formalin- and alcohol-glycerine-treated specimens. The plastic energy absorption of human and bovine specimens was altered significantly. Formalin as well as alcohol-glycerine fixation yielded a significant decrease in plastic energy absorption, whereas Thiel fixation significantly increased the plastic energy absorption. DISCUSSION/
CONCLUSION: Because of the significantly altered plastic mechanical properties of cortical bone, the use fresh-frozen bone specimens is recommended in biomechanical studies investigating failure loads of orthopaedic implants. The use of embalmed specimens should be restricted to pilot tests.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20736094     DOI: 10.1016/j.bone.2010.08.012

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  37 in total

1.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

2.  Thiel-embalming technique: investigation of possible modification in embalming tissue as evaluation model for radiofrequency ablation.

Authors:  Pei-Yu Liao; Zhi-Gang Wang
Journal:  J Biomed Res       Date:  2019-04-08

3.  The loss of activating transcription factor 4 (ATF4) reduces bone toughness and fracture toughness.

Authors:  Alexander J Makowski; Sasidhar Uppuganti; Sandra A Wadeer; Jack M Whitehead; Barbara J Rowland; Mathilde Granke; Anita Mahadevan-Jansen; Xiangli Yang; Jeffry S Nyman
Journal:  Bone       Date:  2014-02-07       Impact factor: 4.398

Review 4.  Human body preservation - old and new techniques.

Authors:  Erich Brenner
Journal:  J Anat       Date:  2014-01-18       Impact factor: 2.610

Review 5.  The Role of Water Compartments in the Material Properties of Cortical Bone.

Authors:  Mathilde Granke; Mark D Does; Jeffry S Nyman
Journal:  Calcif Tissue Int       Date:  2015-03-18       Impact factor: 4.333

6.  The subtalar and talonavicular joints: a way to access the long-term load intake using conventional CT-data.

Authors:  Fabian Mueller; Sebastian Hoechel; Joerg Klaws; Dieter Wirz; Magdalena Müller-Gerbl
Journal:  Surg Radiol Anat       Date:  2013-09-20       Impact factor: 1.246

7.  The amount of information provided in articles published in clinical anatomy and surgical and radiologic anatomy regarding human cadaveric materials and trends in acknowledging donors/cadavers.

Authors:  İlke Ali Gürses; Osman Coşkun; Başak Gürtekin; Ayşin Kale
Journal:  Surg Radiol Anat       Date:  2016-05-05       Impact factor: 1.246

8.  Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

Authors:  W Brent Edwards; Thomas J Schnitzer; Karen L Troy
Journal:  J Biomech       Date:  2013-05-13       Impact factor: 2.712

9.  Characterization of trabecular bone density with ultra-short echo-time MRI at 1.5, 3.0 and 7.0 T--comparison with micro-computed tomography.

Authors:  Moritz C Wurnig; Maurizio Calcagni; David Kenkel; Magdalena Vich; Markus Weiger; Gustav Andreisek; Felix W Wehrli; Andreas Boss
Journal:  NMR Biomed       Date:  2014-08-04       Impact factor: 4.044

10.  Partial removal of pore and loosely bound water by low-energy drying decreases cortical bone toughness in young and old donors.

Authors:  Jeffry S Nyman; Lacey E Gorochow; R Adam Horch; Sasidhar Uppuganti; Ahbid Zein-Sabatto; Mary Katherine Manhard; Mark D Does
Journal:  J Mech Behav Biomed Mater       Date:  2012-10-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.