Literature DB >> 20733890

Mêasurement of corneal thickness by low-coherence interferometry.

C K Hitzenberger.   

Abstract

A special interferometric technique, which uses light of low-coherence length and the Doppler principle, is applied to measurement of the thickness of the human cornea in vivo. The special construction of the instrument eliminates any influence from eye motions on the thickness results. With a superluminescent diode as a light source, a precision of ~ 1.5 microm is obtained. This is ~ 3-8 times better than the precision of existing instruments. Since interobserver and interinstrument variability are avoided by the measurement principle, the improvement in total accuracy, compared with that when existing instruments are used, should be even better.

Entities:  

Year:  1992        PMID: 20733890     DOI: 10.1364/AO.31.006637

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

1.  Assessment of corneal properties based on statistical modeling of OCT speckle.

Authors:  Danilo A Jesus; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2016-12-08       Impact factor: 3.732

2.  Adaptive optics SLO/OCT for 3D imaging of human photoreceptors in vivo.

Authors:  Franz Felberer; Julia-Sophie Kroisamer; Bernhard Baumann; Stefan Zotter; Ursula Schmidt-Erfurth; Christoph K Hitzenberger; Michael Pircher
Journal:  Biomed Opt Express       Date:  2014-01-10       Impact factor: 3.732

3.  Transmural inflammation is not pathognomonic for Crohn's disease of the pouch.

Authors:  Zhao-xiu Liu; Tom Deroche; Feza H Remzi; Jefferey P Hammel; Victor W Fazio; Run-zhou Ni; John R Goldblum; Bo Shen
Journal:  Surg Endosc       Date:  2011-06-10       Impact factor: 4.584

4.  In vivo investigation of human cone photoreceptors with SLO/OCT in combination with 3D motion correction on a cellular level.

Authors:  Michael Pircher; Erich Götzinger; Harald Sattmann; Rainer A Leitgeb; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2010-06-21       Impact factor: 3.894

Review 5.  Optical imaging techniques for point-of-care diagnostics.

Authors:  Hongying Zhu; Serhan O Isikman; Onur Mudanyali; Alon Greenbaum; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-10-09       Impact factor: 6.799

6.  Simultaneous SLO/OCT imaging of the human retina with axial eye motion correction.

Authors:  Michael Pircher; Bernhard Baumann; Erich Götzinger; Harald Sattmann; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2007-12-10       Impact factor: 3.894

7.  Laser interference biometry versus ultrasound biometry in certain clinical conditions.

Authors:  B A M Lege; W Haigis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-11-25       Impact factor: 3.117

  7 in total