Literature DB >> 20723650

Frequency of conduction disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis.

Matthieu Godin1, Helene Eltchaninoff, Akira Furuta, Christophe Tron, Frederic Anselme, Karim Bejar, Carlos Sanchez-Giron, Fabrice Bauer, Pierre-Yves Litzler, Jean-Paul Bessou, Alain Cribier.   

Abstract

We evaluated the incidence of conduction abnormalities and requirement for permanent pacemaker in patients undergoing transcatheter aortic valve implantation (TAVI) with the Edwards Sapien prosthesis. In 2009, >8,000 patients were treated with TAVI using 1 of the 2 commercialized models of bioprosthesis (Edwards Sapien, Edwards Lifesciences, Irvine, California; and CoreValve, Medtronic, Irvine, California). Occurrence of conduction abnormalities including complete atrioventricular block requiring permanent pacemaker has been reported after TAVI with the 2 models of valve, more frequently with the CoreValve. We analyzed standard 12-lead electrocardiograms of 69 consecutive patients in whom an Edwards Sapien prosthesis was successfully implanted. Electrocardiograms were examined before treatment, at day 1, and at 1-month follow-up. Heart rate, PR and QT intervals and QRS duration were measured and the presence of a first-, second-, or third-degree atrioventricular block was documented. There was a slight increase in heart rate and a discrete decrease in QT interval at day 1. These values had returned to baseline values at 1 month. There was no change in PR interval but a transitory increase in QRS duration was noted. Frequency of left bundle branch block increased from 14.5% at baseline to 27.5% at day 1 with a decreased incidence at day 30 (21.3%). Permanent pacemaker was required in only 3 patients (4.3%). In conclusion, in our experience, conductive disorders and requirement of a definitive pacemaker after implantation of an Edwards Sapien aortic bioprosthesis are infrequent. The physical properties of this prosthesis may explain this observation. 2010. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20723650     DOI: 10.1016/j.amjcard.2010.04.029

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  12 in total

1.  Transcatheter resection of the native aortic valve prior to endovalve implantation - A rational approach to reduce TAVI-induced complications.

Authors:  Parla Astarci; Pierre-Yves Etienne; Benoit Raucent; Xavier Bollen; Kahn Tranduy; David Glineur; Laurent Dekerchove; Philippe Noirhomme; Gébrine Elkhoury
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 2.  TAVI 2012: state of the art.

Authors:  Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

3.  Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis.

Authors:  Valeria Calvi; Sergio Conti; Giusi Paola Pruiti; Davide Capodanno; Euglena Puzzangara; Donatella Tempio; Angelo Di Grazia; Gian Paolo Ussia; Corrado Tamburino
Journal:  J Interv Card Electrophysiol       Date:  2011-11-26       Impact factor: 1.900

4.  Transient and persistent conduction abnormalities following transcatheter aortic valve replacement with the Edwards-Sapien prosthesis: a comparison between antegrade vs. retrograde approaches.

Authors:  Solomon J Sager; Abdulla A Damluji; Joshua A Cohen; Sachil Shah; Brian P O'Neill; Carlos E Alfonso; Claudia A Martinez; Robert J Myerburg; Alan W Heldman; Mauricio G Cohen; Donald B Williams; Roger G Carrillo
Journal:  J Interv Card Electrophysiol       Date:  2016-05-28       Impact factor: 1.900

5.  Ongoing requirement for pacing post-transcatheter aortic valve implantation and surgical aortic valve replacement.

Authors:  Alexander D Simms; Andrew J Hogarth; Elizabeth A Hudson; Victoria L Worsnop; Daniel J Blackman; David J O'Regan; Muzahir H Tayebjee
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-25

6.  Clinical impact of a new left bundle branch block following TAVI implantation: 1-year results of the TAVIK cohort.

Authors:  Gerhard Schymik; Panagiotis Tzamalis; Peter Bramlage; Martin Heimeshoff; Alexander Würth; Rainer Wondraschek; Bernd-Dieter Gonska; Herbert Posival; Claus Schmitt; Holger Schröfel; Armin Luik
Journal:  Clin Res Cardiol       Date:  2014-11-12       Impact factor: 5.460

Review 7.  Transcatheter aortic valve implantation: current and future approaches.

Authors:  Josep Rodés-Cabau
Journal:  Nat Rev Cardiol       Date:  2011-11-15       Impact factor: 32.419

8.  The first successful transapical aortic valve implant in Korea.

Authors:  Dong Seop Jeong; Pyo Won Park; Min Suk Choi; Kiick Sung; Wook Sung Kim; Young Tak Lee; Hyeon-Cheol Gwon; Seung Hyuk Choi; Sung-Ji Park; Sang Min Maria Lee
Journal:  J Korean Med Sci       Date:  2011-03-28       Impact factor: 2.153

9.  Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.

Authors:  Esseim Sharma; Antony F Chu
Journal:  J Interv Card Electrophysiol       Date:  2017-12-19       Impact factor: 1.900

10.  Short-term pacemaker dependency after transcatheter aortic valve implantation.

Authors:  Christiana Schernthaner; Johannes Kraus; Franz Danmayr; Matthias Hammerer; Jens Schneider; Uta C Hoppe; Bernhard Strohmer
Journal:  Wien Klin Wochenschr       Date:  2016-01-08       Impact factor: 1.704

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.