Literature DB >> 20696564

Ultrasound decreases the failed labor epidural rate in resident trainees.

M C Vallejo1, A L Phelps, S Singh, S L Orebaugh, N Sah.   

Abstract

BACKGROUND: Epidural analgesia is widely used for pain relief during labor. The purpose of this study was to determine if ultrasound measurement of the depth from skin to epidural space before the epidural technique decreases the failure rate of labor analgesia. A secondary objective was to correlate ultrasound depth to the epidural space with actual depth of the needle at placement.
METHODS: In this prospective, randomized, non-blinded study, 370 parturients requesting labor epidural analgesia were randomized to receive their epidural technique by first year anesthesia residents with or without prior ultrasound determination of epidural space depth. Outcome variables included the incidence of epidural catheter replacement for failed analgesia and the number of epidural attempts and accidental dural punctures.
RESULTS: The ultrasound group had fewer epidural catheter replacements (P<0.02), and epidural placement attempts (P<0.01) compared to the control group. Pearson's correlation coefficients comparing the actual versus ultrasound estimated depth to the epidural space in the longitudinal median and transverse planes were 0.914 and 0.909, respectively. Pearson's correlation coefficient comparing the ultrasound estimated depths to the epidural space in the transverse and longitudinal median planes was 0.940. No significant differences were noted with respect to staff interventions, top-ups, accidental dural punctures, and delivery outcome.
CONCLUSIONS: Ultrasound measurement of the epidural space depth before epidural technique placement decreases the rate of epidural catheter replacements for failed labor analgesia, and reduces the number of epidural attempts when performed by first year residents and compared to attempts without ultrasound guidance.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20696564     DOI: 10.1016/j.ijoa.2010.04.002

Source DB:  PubMed          Journal:  Int J Obstet Anesth        ISSN: 0959-289X            Impact factor:   2.603


  21 in total

1.  Eyes in the needle: novel epidural needle with embedded high-frequency ultrasound transducer--epidural access in porcine model.

Authors:  Huihua K Chiang; Qifa Zhou; M Susan Mandell; Mei-Yung Tsou; Shih-Pin Lin; K Kirk Shung; Chien-Kun Ting
Journal:  Anesthesiology       Date:  2011-06       Impact factor: 7.892

2.  Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

Authors:  Mahmoud Nassar; Ibrahim A Abdelazim
Journal:  J Clin Monit Comput       Date:  2014-10-28       Impact factor: 2.502

3.  Investigating a Needle-Based Epidural Procedure in Obstetric Anesthesia.

Authors:  Eva K Lee; Haozheng Tian; Jinha Lee; Xin Wie; John Neeld; K Doug Smith; Alan R Kaplan
Journal:  AMIA Annu Symp Proc       Date:  2018-12-05

Review 4.  Lumbar Ultrasonography for Obstetric Neuraxial Blocks: Sonoanatomy and Literature Review.

Authors:  Tülay Şahin; Onur Balaban
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-08-01

5.  Prospective evaluation of point-of-care ultrasound for pre-procedure identification of landmarks versus traditional palpation for lumbar puncture.

Authors:  Shadi Lahham; Priel Schmalbach; Sean P Wilson; Lori Ludeman; Mohammad Subeh; Jocelyn Chao; Nadeem Albadawi; Niki Mohammadi; John C Fox
Journal:  World J Emerg Med       Date:  2016

6.  Recommendations on the Use of Ultrasound Guidance for Adult Lumbar Puncture: A Position Statement of the Society of Hospital Medicine.

Authors:  Nilam J Soni; Ricardo Franco-Sadud; Ketino Kobaidze; Daniel Schnobrich; Gerard Salame; Joshua Lenchus; Venkat Kalidindi; Michael J Mader; Elizabeth K Haro; Ria Dancel; Joel Cho; Loretta Grikis; Brian P Lucas
Journal:  J Hosp Med       Date:  2019-06-10       Impact factor: 2.960

7.  Imaging Performance of a Handheld Ultrasound System With Real-Time Computer-Aided Detection of Lumbar Spine Anatomy: A Feasibility Study.

Authors:  Mohamed Tiouririne; Adam J Dixon; F William Mauldin; David Scalzo; Arun Krishnaraj
Journal:  Invest Radiol       Date:  2017-08       Impact factor: 6.016

8.  Feasibility of ultrasound-guided lumbar epidural access using paramedian transverse scanning with the needle in-plane: a comparison with paramedian sagittal scanning.

Authors:  Huili Li; Yi Kang; Li Jin; Danxu Ma; Yang Liu; Yun Wang
Journal:  J Anesth       Date:  2019-10-30       Impact factor: 2.078

9.  Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion.

Authors:  Ahmed M Hasanin; Ali M Mokhtar; Shereen M Amin; Ahmed A Sayed
Journal:  Saudi J Anaesth       Date:  2017 Jan-Mar

10.  Epidural catheter placement in morbidly obese parturients with the use of an epidural depth equation prior to ultrasound visualization.

Authors:  Sukhdip Singh; Keith M Wirth; Amy L Phelps; Manasi H Badve; Tanmay H Shah; Neera Sah; Manuel C Vallejo
Journal:  ScientificWorldJournal       Date:  2013-07-25
View more