Literature DB >> 20688448

Unambiguous identification of superparamagnetic iron oxide particles through quantitative susceptibility mapping of the nonlinear response to magnetic fields.

Tian Liu1, Pascal Spincemaille, Ludovic de Rochefort, Richard Wong, Martin Prince, Yi Wang.   

Abstract

Superparamagnetic iron oxide (SPIO) particles generate signal void regions on gradient echo images due to their strong magnetization. In practice, the signal void region might be indistinguishable from that generated by air. However, the response of SPIO to an externally applied magnetic field is nonlinear. Magnetization of SPIO saturates at around 1 T while magnetization of water and air increase linearly with field strength. Phantom experiment and mice experiments demonstrated the feasibility of a nonambiguous identification of superparamagnetic contrast agents.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20688448      PMCID: PMC2963706          DOI: 10.1016/j.mri.2010.06.011

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  22 in total

1.  MRI detection of single particles for cellular imaging.

Authors:  Erik M Shapiro; Stanko Skrtic; Kathryn Sharer; Jonathan M Hill; Cynthia E Dunbar; Alan P Koretsky
Journal:  Proc Natl Acad Sci U S A       Date:  2004-07-15       Impact factor: 11.205

2.  Susceptibility mapping in the human brain using threshold-based k-space division.

Authors:  Sam Wharton; Andreas Schäfer; Richard Bowtell
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

3.  Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles.

Authors:  Charles H Cunningham; Takayasu Arai; Phillip C Yang; Michael V McConnell; John M Pauly; Steven M Conolly
Journal:  Magn Reson Med       Date:  2005-05       Impact factor: 4.668

4.  Tomographic imaging using the nonlinear response of magnetic particles.

Authors:  Bernhard Gleich; Jürgen Weizenecker
Journal:  Nature       Date:  2005-06-30       Impact factor: 49.962

5.  Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

Authors:  Matthias Stuber; Wesley D Gilson; Michael Schär; Dorota A Kedziorek; Lawrence V Hofmann; Saurabh Shah; Evert-Jan Vonken; Jeff W M Bulte; Dara L Kraitchman
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

6.  Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI.

Authors:  Tian Liu; Pascal Spincemaille; Ludovic de Rochefort; Bryan Kressler; Yi Wang
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

7.  Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field.

Authors:  Ludovic de Rochefort; Ryan Brown; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

Review 8.  Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging.

Authors:  Y X Wang; S M Hussain; G P Krestin
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

9.  Estimating amounts of iron oxide from gradient echo images.

Authors:  W Thomas Dixon; Daniel J Blezek; Lisa A Lowery; Dan E Meyer; Amit M Kulkarni; Brian C Bales; Danielle L Petko; Thomas K Foo
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  Detection of hemorrhagic hypointense foci in the brain on susceptibility-weighted imaging clinical and phantom studies.

Authors:  Masuma Akter; Toshinori Hirai; Yasuhiro Hiai; Mika Kitajima; Masanori Komi; Ryuji Murakami; Hirofumi Fukuoka; Akira Sasao; Ryo Toya; E Mark Haacke; Mutsumasa Takahashi; Teruyuki Hirano; Yutaka Kai; Motohiro Morioka; Kiyotoshi Hamasaki; Jun-Ichi Kuratsu; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2007-09       Impact factor: 3.173

View more
  27 in total

1.  Cerebral microbleeds: burden assessment by using quantitative susceptibility mapping.

Authors:  Tian Liu; Krishna Surapaneni; Min Lou; Liuquan Cheng; Pascal Spincemaille; Yi Wang
Journal:  Radiology       Date:  2011-11-04       Impact factor: 11.105

2.  Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Authors:  Jie Luo; Bharathi D Jagadeesan; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2012-01-28       Impact factor: 6.556

3.  Fidelity imposed network edit (FINE) for solving ill-posed image reconstruction.

Authors:  Jinwei Zhang; Zhe Liu; Shun Zhang; Hang Zhang; Pascal Spincemaille; Thanh D Nguyen; Mert R Sabuncu; Yi Wang
Journal:  Neuroimage       Date:  2020-01-22       Impact factor: 6.556

4.  Whole brain susceptibility mapping using compressed sensing.

Authors:  Bing Wu; Wei Li; Arnaud Guidon; Chunlei Liu
Journal:  Magn Reson Med       Date:  2011-06-10       Impact factor: 4.668

5.  Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping.

Authors:  Jianqi Li; Shixin Chang; Tian Liu; Hongwei Jiang; Fang Dong; Mengchao Pei; Qianfeng Wang; Yi Wang
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

6.  An iterative spherical mean value method for background field removal in MRI.

Authors:  Yan Wen; Dong Zhou; Tian Liu; Pascal Spincemaille; Yi Wang
Journal:  Magn Reson Med       Date:  2013-11-19       Impact factor: 4.668

7.  Establishing the overlap of IONP quantification with echo and echoless MR relaxation mapping.

Authors:  Hattie L Ring; Jinjin Zhang; Nathan D Klein; Lynn E Eberly; Christy L Haynes; Michael Garwood
Journal:  Magn Reson Med       Date:  2017-06-26       Impact factor: 4.668

8.  On the role of neuronal magnetic susceptibility and structure symmetry on gradient echo MR signal formation.

Authors:  Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2013-02-04       Impact factor: 4.668

9.  Clinical Integration of Automated Processing for Brain Quantitative Susceptibility Mapping: Multi-Site Reproducibility and Single-Site Robustness.

Authors:  Pascal Spincemaille; Zhe Liu; Shun Zhang; Ilhami Kovanlikaya; Matteo Ippoliti; Marcus Makowski; Richard Watts; Ludovic de Rochefort; Vijay Venkatraman; Patricia Desmond; Mathieu D Santin; Stéphane Lehéricy; Brian H Kopell; Patrice Péran; Yi Wang
Journal:  J Neuroimaging       Date:  2019-08-04       Impact factor: 2.486

10.  Magnetic barcode imaging for contrast agents.

Authors:  Andy H Hung; Laura M Lilley; Fengqin Hu; Victoria S R Harrison; Thomas J Meade
Journal:  Magn Reson Med       Date:  2016-04-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.