Literature DB >> 19215047

Estimating amounts of iron oxide from gradient echo images.

W Thomas Dixon1, Daniel J Blezek, Lisa A Lowery, Dan E Meyer, Amit M Kulkarni, Brian C Bales, Danielle L Petko, Thomas K Foo.   

Abstract

Rat legs directly injected with superparamagnetic iron oxide (SPIO) were studied by dual-echo, gradient-echo imaging. The amount of iron injected was estimated using a point dipole model for the SPIO injection site. Saturation magnetization of 6:1 PEG/amino modified silane-coated iron oxide particles with 5- to 6-nm core and 20-25 hydrodynamic diameter was approximately 110 emu/g of iron. Estimates of the amount of iron injected made from signal void volumes surrounding SPIO centers yielded erroneous results varying with sample orientation in the scanner and echo time (TE). For example, a 10 microL, 3-microg iron injection produced signal void volumes of 80 and 210 microL at TE of 9.8 and 25 ms, respectively, giving apparent iron contents of 6 +/- 1 and 10 +/- 2 microg respectively. A more effective approach uses the phase difference between two gradient recalled echo images. To estimate iron content, this approach fits the expected (3 cos(2)theta - 1)/(/r/3) spatial phase distribution to the observed phase differences. Extraneous phase effects made fitting phase at a single TE ineffective. With the dual echo method, 18 independent estimates were 2.48 +/- 0.26 microg std, independently of sample orientation. Estimates in empty control regions were -90 and -140 ng. A 1-microg injection indicated 0.5, 1.2, and 1.2 microg. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19215047     DOI: 10.1002/mrm.21930

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Tracking and Quantification of Magnetically Labeled Stem Cells using Magnetic Resonance Imaging.

Authors:  Forrest Goodfellow; Gregory A Simchick; Luke J Mortensen; Steven L Stice; Qun Zhao
Journal:  Adv Funct Mater       Date:  2016-02-17       Impact factor: 18.808

2.  Unambiguous identification of superparamagnetic iron oxide particles through quantitative susceptibility mapping of the nonlinear response to magnetic fields.

Authors:  Tian Liu; Pascal Spincemaille; Ludovic de Rochefort; Richard Wong; Martin Prince; Yi Wang
Journal:  Magn Reson Imaging       Date:  2010-08-04       Impact factor: 2.546

3.  Automated detection and characterization of SPIO-labeled cells and capsules using magnetic field perturbations.

Authors:  Parker H Mills; T Kevin Hitchens; Lesley M Foley; Thomas Link; Qing Ye; Clifford R Weiss; Joe D Thompson; Wesley D Gilson; Aravind Arepally; John A Melick; Patrick M Kochanek; Chien Ho; Jeff W M Bulte; Eric T Ahrens
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

4.  Quantification of SPIO nanoparticles in vivo using the finite perturber method.

Authors:  Jason Langley; Wei Liu; E Kay Jordan; J A Frank; Qun Zhao
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

5.  Magnetic nanoparticle-based hyperthermia for head & neck cancer in mouse models.

Authors:  Qun Zhao; Luning Wang; Rui Cheng; Leidong Mao; Robert D Arnold; Elizabeth W Howerth; Zhuo G Chen; Simon Platt
Journal:  Theranostics       Date:  2012-01-15       Impact factor: 11.556

6.  Quantitative assessment of microvasculopathy in arcAβ mice with USPIO-enhanced gradient echo MRI.

Authors:  Jan Klohs; Andreas Deistung; Giovanna D Ielacqua; Aline Seuwen; Diana Kindler; Ferdinand Schweser; Markus Vaas; Anja Kipar; Jürgen R Reichenbach; Markus Rudin
Journal:  J Cereb Blood Flow Metab       Date:  2015-12-01       Impact factor: 6.200