Literature DB >> 20680260

Secondary residual shunt after atrial septal defect closure with an amplatzer occluder: surgical removal and evaluation of device biocompatibility after 7 years.

Weihua Zhu1, Henning Neubauer.   

Abstract

Interventional occluder implantation has become the preferred mode of treatment in children with clinically significant atrial septal defect (ASD). The continuous increase in the number of patients treated calls for long-term data on device integrity and biocompatibility. We report a child who underwent successful interventional ASD closure at age 5 years. Secondary residual shunt occurred after 3 years of follow-up, and surgical ASD closure became necessary at age 12 years. The Amplatzer occluder device, which was removed after 7 years in vivo, showed no signs of mechanical failure, corrosion, or clinically relevant immunological response at the device-tissue interface.

Entities:  

Mesh:

Year:  2010        PMID: 20680260     DOI: 10.1007/s00246-010-9757-y

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  11 in total

1.  Histopathological workup of an Amplatzer atrial septal defect occluder after surgical removal.

Authors:  Matthias Sigler; Christian Jux; Peter Ewert
Journal:  Pediatr Cardiol       Date:  2006-10-09       Impact factor: 1.655

2.  Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial.

Authors:  Zhong Dong Du; Ziyad M Hijazi; Charles S Kleinman; Norman H Silverman; Kinley Larntz
Journal:  J Am Coll Cardiol       Date:  2002-06-05       Impact factor: 24.094

3.  Biocompatibility of septal defect closure devices.

Authors:  Matthias Sigler; Christian Jux
Journal:  Heart       Date:  2006-10-11       Impact factor: 5.994

4.  Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience.

Authors:  J Masura; P Gavora; A Formanek; Z M Hijazi
Journal:  Cathet Cardiovasc Diagn       Date:  1997-12

Review 5.  Biocompatibility screening in cardiovascular implants.

Authors:  M Sigler; T Paul; R G Grabitz
Journal:  Z Kardiol       Date:  2005-06

6.  Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders.

Authors:  Jozef Masura; Pavol Gavora; Tomaz Podnar
Journal:  J Am Coll Cardiol       Date:  2005-02-15       Impact factor: 24.094

7.  Transcatheter closure of secundum atrial septal defect using an Amplatzer septal occluder.

Authors:  Xiangqing Kong; Kejiang Cao; Rong Yang; Di Xu; Yanhui Sheng; Jun Huang; Wenzhu Ma
Journal:  Chin Med J (Engl)       Date:  2002-01       Impact factor: 2.628

8.  A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model.

Authors:  Zhong-Ru Ding; Yong-Wen Qin; Jian-Qiang Hu; Xian-Xian Zhao; Zhi-Hong Yang; Jiang Cao
Journal:  J Interv Cardiol       Date:  2009-04       Impact factor: 2.279

9.  Transcatheter closure of atrial septal defects in children & adults using the Amplatzer Septal Occluder.

Authors:  A Omeish; Z M Hijazi
Journal:  J Interv Cardiol       Date:  2001-02       Impact factor: 2.279

10.  Corrosive behaviour of Amplatzer devices in experimental and biological environments.

Authors:  Huafu Kong; James L Wilkinson; James Y Coe; Xiaoping Gu; Myra Urness; Tae-Hoon Kim; John L Bass
Journal:  Cardiol Young       Date:  2002-05       Impact factor: 1.093

View more
  3 in total

1.  Cardiac tamponade due to perforation by an Amplatzer atrial septal occluder in a patient with Marfan syndrome.

Authors:  Minori Tateishi; Takeshi Hiramatsu; Yasuko Tomizawa; Goki Matsumura; Takeshi Konuma; Kenji Yamazaki; Hideshi Yamamura; Toshio Nakanishi
Journal:  J Artif Organs       Date:  2011-06-03       Impact factor: 1.731

Review 2.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

3.  [MRI for therapy planning in patients with atrial septum defects].

Authors:  A Huber; M Prompona; R Kozlik-Feldmann; O Mühling; E Rummeny; M Reiser; D Theisen
Journal:  Radiologe       Date:  2011-01       Impact factor: 0.635

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.