Literature DB >> 20677237

Motion correction in MR thermometry of abdominal organs: a comparison of the referenceless vs. the multibaseline approach.

Baudouin Denis de Senneville1, Sébastien Roujol, Chrit Moonen, Mario Ries.   

Abstract

Reliable temperature and thermal-dose measurements using proton resonance frequency shift-based magnetic resonance (MR) thermometry for MR-guided ablation of abdominal organs require a robust correction of artefacts induced by the target displacement through an inhomogeneous and time-variant magnetic field. Two correction approaches emerged recently as promising candidates to allow continuous real-time MR-thermometry under free-breathing conditions: The multibaseline correction method, which relies on a pre-recorded correction table allowing to correct for periodic phase changes, and the referenceless method, which depends on a background phase estimation in the target area based on the assumption of a smooth spatial variation of the phase across the organ. This study combines both methods with real-time in-plane motion correction to permit both temperature and thermal-dose calculations on the fly. Subsequently, the practical aspects of both methods are compared in two application scenarios, a radio frequency-ablation and a high-intensity focused ultrasound ablation. A hybrid approach is presented that exploits the strong points of both methods, allowing accurate and precise proton resonance frequency-thermometry measurements during periodical displacement, even in the presence of spontaneous motion and strong susceptibility variations in the target area.
Copyright © 2010 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 20677237     DOI: 10.1002/mrm.22514

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Ultrasound echoes as biometric navigators.

Authors:  Benjamin M Schwartz; Nathan J McDannold
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

Review 2.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

3.  [MRI for monitoring of high intensity focused ultrasound: current developments].

Authors:  C G Trumm; R Stahl; M Peller; D-A Clevert; A Huber; M F Reiser; M Matzko
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

4.  Effects of air susceptibility on proton resonance frequency MR thermometry.

Authors:  Markus N Streicher; Andreas Schäfer; Enrico Reimer; Bibek Dhital; Robert Trampel; Dimo Ivanov; Robert Turner
Journal:  MAGMA       Date:  2011-04-10       Impact factor: 2.310

5.  Temperature imaging of laser-induced thermotherapy (LITT) by MRI: evaluation of different sequences in phantom.

Authors:  Babak Bazrafshan; Frank Hübner; Parviz Farshid; Renate Hammerstingl; Jijo Paul; Vitali Vogel; Werner Mäntele; Thomas J Vogl
Journal:  Lasers Med Sci       Date:  2013-03-28       Impact factor: 3.161

6.  Histotripsy cardiac therapy system integrated with real-time motion correction.

Authors:  Ryan M Miller; Yohan Kim; Kuang-Wei Lin; Charles A Cain; Gabe E Owens; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2013-09-21       Impact factor: 2.998

7.  Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array.

Authors:  Vasant A Salgaonkar; Punit Prakash; Viola Rieke; Eugene Ozhinsky; Juan Plata; John Kurhanewicz; I-C Joe Hsu; Chris J Diederich
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

8.  Motion-compensated real-time MR thermometry augmented by tracking coils.

Authors:  Peng Wang; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2014-01-30       Impact factor: 4.813

9.  Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.

Authors:  Chenchen Bing; Robert M Staruch; Matti Tillander; Max O Köhler; Charles Mougenot; Mika Ylihautala; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2016-05-22       Impact factor: 3.914

10.  Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver.

Authors:  G D Pandeya; J H G M Klaessens; M J W Greuter; B Schmidt; T Flohr; R van Hillegersberg; M Oudkerk
Journal:  Eur Radiol       Date:  2011-03-24       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.