SUMMARY: We evaluated the accuracy of plain skull x-ray series as an imaging modality for the follow-up of cerebral aneurysm recanalization after Guglielmi Detachable Coil (GDC) embolisation. We retrospectively reviewed of 100 consecutive follow-up angiograms and skull x-ray examinations in 78 patients harboring 82 aneurysms and in whom 85 procedures were performed. Angiography was performed between 1 and 54 months (mean: 10.8 months) after embolisation. The skull series (AP, lateral and Towne's projections) were taken at the time of follow-up angiography. Each follow-up angiogram and skull series were compared to the immediate post-coiling, correlating presence or absence of coil compaction on the skull series and recanalization of the aneurysm at angiography. In 97 (97%) examinations, skull x-ray findings correlated with the angiographic findings. In three cases, skull x-ray examination suggested compaction when no recanalization was seen angiographically; in these three cases, the aneurysms were small and found to be more thrombosed than baseline. In no case did angiographic recanalization occur in the absence of compaction on skull series. These findings yield 100% sensitivity, 95% specificity, 93% positive predictive value, 100% negative predictive value and 97% accuracy. The location, size, configuration and neck/dome ratio of the aneurysm were not related to the correlation between angiography and skull x-ray exam. Skull x-ray series is a safe, accurate, and costeffective mode of follow-up for patients with GDC-treated aneurysms. The possibility of it replacing angiography still requires a more comparative skull x-ray modality in follow-up studies.

Entities:  

Year:  2001        PMID: 20667198      PMCID: PMC3679677          DOI: 10.1177/159101990000600304

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  25 in total

Review 1.  Treatment of intracranial aneurysms by embolization with coils: a systematic review.

Authors:  E H Brilstra; G J Rinkel; Y van der Graaf; W J van Rooij; A Algra
Journal:  Stroke       Date:  1999-02       Impact factor: 7.914

2.  Effects of ionic and non-ionic contrast media after selective peripheral and cerebral arterial injections in rats.

Authors:  W Mützel; U Speck
Journal:  Fortschr Geb Rontgenstrahlen Nuklearmed Erganzungsbd       Date:  1983

Review 3.  Cerebral angiographic risk in mild cerebrovascular disease.

Authors:  G J Hankey; C P Warlow; R J Sellar
Journal:  Stroke       Date:  1990-02       Impact factor: 7.914

4.  Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils.

Authors:  L Brunereau; J P Cottier; C B Sonier; B Medioni; P Bertrand; P Rouleau; D Sirinelli; D Herbreteau
Journal:  J Comput Assist Tomogr       Date:  1999 Mar-Apr       Impact factor: 1.826

5.  Intracranial aneurysms: endovascular treatment with mechanical detachable spirals in 60 aneurysms.

Authors:  C Cognard; L Pierot; A Boulin; A Weill; M Tovi; L Castaings; A Rey; J Moret; M Toevi
Journal:  Radiology       Date:  1997-03       Impact factor: 11.105

6.  Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results.

Authors:  G Guglielmi; F Viñuela; I Sepetka; V Macellari
Journal:  J Neurosurg       Date:  1991-07       Impact factor: 5.115

7.  Does electrothrombosis occur immediately after embolization of an aneurysm with Guglielmi detachable coils?

Authors:  M Horowitz; D Samson; P Purdy
Journal:  AJNR Am J Neuroradiol       Date:  1997-03       Impact factor: 3.825

8.  Endovascular treatment of anterior communicating artery aneurysms using Guglielmi detachable coils.

Authors:  J Moret; L Pierot; A Boulin; L Castaings; A Rey
Journal:  Neuroradiology       Date:  1996-11       Impact factor: 2.804

9.  Patient dose and image quality in five standard x-ray examinations.

Authors:  R Havukainen; M Pirinen
Journal:  Med Phys       Date:  1993 May-Jun       Impact factor: 4.071

10.  In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation.

Authors:  Y P Gobin; J L Counord; P Flaud; J Duffaux
Journal:  Neuroradiology       Date:  1994-10       Impact factor: 2.804

View more
  3 in total

1.  Efficacy of skull plain films in follow-up evaluation of cerebral aneurysms treated with detachable coils: quantitative assessment of coil mass.

Authors:  S J Ahn; B M Kim; W S Jung; S H Suh
Journal:  AJNR Am J Neuroradiol       Date:  2014-10-16       Impact factor: 3.825

2.  Comparison of the association of sac growth and coil compaction with recurrence in coil embolized cerebral aneurysms.

Authors:  Anna L Hoppe; Madhavan L Raghavan; David M Hasan
Journal:  PLoS One       Date:  2015-04-20       Impact factor: 3.240

3.  Usefulness of Craniograms in Discriminating Coiled Intracranial Aneurysms Requiring Retreatment.

Authors:  Ryuta Yasuda; Tetsu Satow; Naoki Hashimura; Masaki Nishimura; Jun C Takahashi; Hiroharu Kataoka
Journal:  Neurol Med Chir (Tokyo)       Date:  2021-12-08       Impact factor: 1.742

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.