Literature DB >> 20665896

Modified pulsed continuous arterial spin labeling for labeling of a single artery.

Weiying Dai1, Philip M Robson, Ajit Shankaranarayanan, David C Alsop.   

Abstract

Imaging the contribution of different arterial vessels to the blood supply of the brain can potentially guide the treatment of vascular disease and other disorders. Previously available only with catheter angiography, vessel-selective labeling of arteries has now been demonstrated with pulsed and continuous arterial spin labeling methods. Pulsed continuous labeling, which permits continuous labeling on standard scanner radiofrequency hardware, has been used to encode the contribution of different vessels to the blood supply of the brain. Vessel encoding requires a longer scan and a more complex reconstruction algorithm and may be more sensitive to fluctuations in flow, however. Here a method is presented for single-artery selective labeling, in which a disk around the targeted vessel is labeled. Based on pulsed continuous labeling, this method is achieved by rotating the directions of added in-plane gradients. Numerical simulations of the simplest strategy show good efficiency but poor suppression of labeling at large distances from the target vessel. Amplitude modulation of the rotating in-plane gradients results in better suppression of distant vessels. In vivo results demonstrate highly selective labeling of individual vessels and a rapid falloff of the labeling with distance from the center of the labeling disk, in agreement with the simulations.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20665896      PMCID: PMC3266713          DOI: 10.1002/mrm.22363

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.

Authors:  Hanzhang Lu; Chekesha Clingman; Xavier Golay; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

2.  Continuous artery-selective spin labeling (CASSL).

Authors:  Richard Werner; David G Norris; Karsten Alfke; H Maximilian Mehdorn; Olav Jansen
Journal:  Magn Reson Med       Date:  2005-05       Impact factor: 4.668

3.  Symptomatic carotid artery occlusion: flow territories of major brain-feeding arteries.

Authors:  Peter Jan van Laar; Jeroen Hendrikse; Catharina J M Klijn; L Jaap Kappelle; Matthias J P van Osch; Jeroen van der Grond
Journal:  Radiology       Date:  2007-02       Impact factor: 11.105

4.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

5.  Mapping of vertebral artery perfusion territories using arterial spin labeling MRI.

Authors:  Akash P Kansagra; Eric C Wong
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

6.  NMR measurement of perfusion using arterial spin labeling without saturation of macromolecular spins.

Authors:  W Zhang; A C Silva; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

Review 7.  Tissue specific perfusion imaging using arterial spin labeling.

Authors:  J A Detre; W Zhang; D A Roberts; A C Silva; D S Williams; D J Grandis; A P Koretsky; J S Leigh
Journal:  NMR Biomed       Date:  1994-03       Impact factor: 4.044

8.  Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm.

Authors:  Toshi Abe; Masaru Hirohata; Norimitsu Tanaka; Yusuke Uchiyama; Kazuyuki Kojima; Kiminori Fujimoto; Alexander M Norbash; Naofumi Hayabuchi
Journal:  AJNR Am J Neuroradiol       Date:  2002-04       Impact factor: 3.825

9.  Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

Authors:  Toshinori Hirai; Yukunori Korogi; Kenji Suginohara; Ken Ono; Tomohiro Nishi; Shozaburo Uemura; Masayuki Yamura; Yasuyuki Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

Review 10.  Brain perfusion territory imaging: methods and clinical applications of selective arterial spin-labeling MR imaging.

Authors:  Peter Jan van Laar; Jeroen van der Grond; Jeroen Hendrikse
Journal:  Radiology       Date:  2008-02       Impact factor: 11.105

View more
  21 in total

1.  Highly accelerated vessel-selective arterial spin labeling angiography using sparsity and smoothness constraints.

Authors:  S Sophie Schauman; Mark Chiew; Thomas W Okell
Journal:  Magn Reson Med       Date:  2019-09-19       Impact factor: 4.668

2.  A kinetic model for vessel-encoded dynamic angiography with arterial spin labeling.

Authors:  Thomas W Okell; Michael A Chappell; Ursula G Schulz; Peter Jezzard
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

Review 3.  Applications of arterial spin labeled MRI in the brain.

Authors:  John A Detre; Hengyi Rao; Danny J J Wang; Yu Fen Chen; Ze Wang
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

4.  Cognition and Hemodynamics.

Authors:  Vera Novak
Journal:  Curr Cardiovasc Risk Rep       Date:  2012-10

Review 5.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

Review 6.  Recent progress in ASL.

Authors:  Luis Hernandez-Garcia; Anish Lahiri; Jonas Schollenberger
Journal:  Neuroimage       Date:  2018-01-03       Impact factor: 6.556

7.  Transcranial Doppler-Based Surrogates for Cerebral Blood Flow: A Statistical Study.

Authors:  Joseph Hart; Vera Novak; Charles Saunders; Pierre A Gremaud
Journal:  PLoS One       Date:  2016-11-23       Impact factor: 3.240

8.  Practical considerations for territorial perfusion mapping in the cerebral circulation using super-selective pseudo-continuous arterial spin labeling.

Authors:  Jonas Schollenberger; C Alberto Figueroa; Jon-Fredrik Nielsen; Luis Hernandez-Garcia
Journal:  Magn Reson Med       Date:  2019-08-16       Impact factor: 4.668

9.  Rapid 3D dynamic arterial spin labeling with a sparse model-based image reconstruction.

Authors:  Li Zhao; Samuel W Fielden; Xue Feng; Max Wintermark; John P Mugler; Craig H Meyer
Journal:  Neuroimage       Date:  2015-07-11       Impact factor: 6.556

10.  Time-resolved angiography using inflow subtraction (TRAILS).

Authors:  Daniel Kopeinigg; Roland Bammer
Journal:  Magn Reson Med       Date:  2013-10-24       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.