Literature DB >> 20665782

Reducing distortions in diffusion-weighted echo planar imaging with a dual-echo blip-reversed sequence.

Daniel Gallichan1, Jesper L R Andersson, Mark Jenkinson, Matthew D Robson, Karla L Miller.   

Abstract

The inherent distortions in echo-planar imaging that arise due to inhomogeneities in the static magnetic field can lead to difficulties when attempting to obtain structurally accurate diffusion-tensor imaging data. Parallel acceleration techniques can reduce the magnitude of these distortions but do not remove them entirely. Images can be corrected using a measured field map, but this is prone to error. One approach to correcting for these distortions, referred to here as "blip-reversed" echo-planar imaging, involves collecting a second set of images with the phase encoding reversed. Here, a novel approach to collecting blip-reversed echo-planar imaging data for diffusion-tensor imaging is presented: a dual-echo sequence is used in which the phase-encoding direction of the second echo is swapped compared to the first echo. This allows benefits of the blip-reversed approach to be exploited, with only a modest increase in scan time and, due to the extra data acquired, no significant loss of signal-to-noise efficiency. A novel approach to recombining blip-reversed data is also presented, which involves refining the measured field map, using an algorithm to minimize the difference between the corrected images. The field map refinement is also applicable to conventionally acquired blip-reversed sequences.

Mesh:

Year:  2010        PMID: 20665782     DOI: 10.1002/mrm.22318

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Diffusion-weighted imaging with dual-echo echo-planar imaging for better sensitivity to acute stroke.

Authors:  S J Holdsworth; K W Yeom; M U Antonucci; J B Andre; J Rosenberg; M Aksoy; M Straka; N J Fischbein; R Bammer; M E Moseley; G Zaharchuk; S Skare
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-24       Impact factor: 3.825

2.  Dynamic correction of artifacts due to susceptibility effects and time-varying eddy currents in diffusion tensor imaging.

Authors:  Trong-Kha Truong; Nan-kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2011-06-14       Impact factor: 6.556

3.  Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization.

Authors:  Chitresh Bhushan; Justin P Haldar; Soyoung Choi; Anand A Joshi; David W Shattuck; Richard M Leahy
Journal:  Neuroimage       Date:  2015-03-27       Impact factor: 6.556

4.  Motion-robust diffusion compartment imaging using simultaneous multi-slice acquisition.

Authors:  Bahram Marami; Benoit Scherrer; Shadab Khan; Onur Afacan; Sanjay P Prabhu; Mustafa Sahin; Simon K Warfield; Ali Gholipour
Journal:  Magn Reson Med       Date:  2018-11-16       Impact factor: 4.668

5.  DR-BUDDI (Diffeomorphic Registration for Blip-Up blip-Down Diffusion Imaging) method for correcting echo planar imaging distortions.

Authors:  M Okan Irfanoglu; Pooja Modi; Amritha Nayak; Elizabeth B Hutchinson; Joelle Sarlls; Carlo Pierpaoli
Journal:  Neuroimage       Date:  2014-11-26       Impact factor: 6.556

6.  Synthesized b0 for diffusion distortion correction (Synb0-DisCo).

Authors:  Kurt G Schilling; Justin Blaber; Yuankai Huo; Allen Newton; Colin Hansen; Vishwesh Nath; Andrea T Shafer; Owen Williams; Susan M Resnick; Baxter Rogers; Adam W Anderson; Bennett A Landman
Journal:  Magn Reson Imaging       Date:  2019-05-07       Impact factor: 2.546

7.  A registration method for improving quantitative assessment in probabilistic diffusion tractography.

Authors:  J L Waugh; J K Kuster; M L Makhlouf; J M Levenstein; T J Multhaupt-Buell; S K Warfield; N Sharma; A J Blood
Journal:  Neuroimage       Date:  2019-01-03       Impact factor: 6.556

8.  Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling.

Authors:  Neville D Gai; Yi Yu Chou; Dzung Pham; John A Butman
Journal:  Magn Reson Imaging       Date:  2017-09-01       Impact factor: 2.546

9.  Improved B0 -distortion correction in diffusion MRI using interlaced q-space sampling and constrained reconstruction.

Authors:  Chitresh Bhushan; Anand A Joshi; Richard M Leahy; Justin P Haldar
Journal:  Magn Reson Med       Date:  2013-11-11       Impact factor: 4.668

10.  Dynamic and inherent B0 correction for DTI using stimulated echo spiral imaging.

Authors:  Alexandru V Avram; Arnaud Guidon; Trong-Kha Truong; Chunlei Liu; Allen W Song
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.