PURPOSE: To present a novel technique for high-resolution stimulated echo diffusion tensor imaging with self-navigated interleaved spirals readout trajectories that can inherently and dynamically correct for image artifacts due to spatial and temporal variations in the static magnetic field (B0) resulting from eddy currents, tissue susceptibilities, subject/physiological motion, and hardware instabilities.
METHODS: The Hahn spin echo formed by the first two 90° radiofrequency pulses is balanced to consecutively acquire two additional images with different echo times and generate an inherent field map, while the diffusion-prepared stimulated echo signal remains unaffected. For every diffusion-encoding direction, an intrinsically registered field map is estimated dynamically and used to effectively and inherently correct for off-resonance artifacts in the reconstruction of the corresponding diffusion-weighted image.
RESULTS: After correction with the dynamically acquired field maps, local blurring artifacts are specifically removed from individual stimulated echo diffusion-weighted images and the estimated diffusion tensors have significantly improved spatial accuracy and larger fractional anisotropy.
CONCLUSION: Combined with the self-navigated interleaved spirals acquisition scheme, our new method provides an integrated high-resolution short-echo time diffusion tensor imaging solution with inherent and dynamic correction for both motion-induced phase errors and off-resonance effects.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 23630029      PMCID: PMC3760972          DOI: 10.1002/mrm.24767

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

Authors:  Nils Bodammer; Jörn Kaufmann; Martin Kanowski; Claus Tempelmann
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Myelin water weighted diffusion tensor imaging.

Authors:  Alexandru V Avram; Arnaud Guidon; Allen W Song
Journal:  Neuroimage       Date:  2010-06-16       Impact factor: 6.556

3.  Q-ball imaging.

Authors:  David S Tuch
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

4.  Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

Authors:  Chunlei Liu; Roland Bammer; Dong-Hyun Kim; Michael E Moseley
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

5.  Deblurring for non-2D Fourier transform magnetic resonance imaging.

Authors:  D C Noll; J M Pauly; C H Meyer; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-06       Impact factor: 4.668

6.  A simplified method to measure the diffusion tensor from seven MR images.

Authors:  P J Basser; C Pierpaoli
Journal:  Magn Reson Med       Date:  1998-06       Impact factor: 4.668

7.  Toward a quantitative assessment of diffusion anisotropy.

Authors:  C Pierpaoli; P J Basser
Journal:  Magn Reson Med       Date:  1996-12       Impact factor: 4.668

8.  MR imaging of human brain at 3.0 T: preliminary report on transverse relaxation rates and relation to estimated iron content.

Authors:  N Gelman; J M Gorell; P B Barker; R M Savage; E M Spickler; J P Windham; R A Knight
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

9.  MR diffusion tensor spectroscopy and imaging.

Authors:  P J Basser; J Mattiello; D LeBihan
Journal:  Biophys J       Date:  1994-01       Impact factor: 4.033

10.  In vivo visualization of myelin water in brain by magnetic resonance.

Authors:  A MacKay; K Whittall; J Adler; D Li; D Paty; D Graeb
Journal:  Magn Reson Med       Date:  1994-06       Impact factor: 4.668

View more
  4 in total

1.  Magnetic resonance microdynamic imaging reveals distinct tissue microenvironments.

Authors:  Dan Benjamini; Peter J Basser
Journal:  Neuroimage       Date:  2017-09-22       Impact factor: 6.556

2.  High-resolution mapping and digital atlas of subcortical regions in the macaque monkey based on matched MAP-MRI and histology.

Authors:  Kadharbatcha S Saleem; Alexandru V Avram; Daniel Glen; Cecil Chern-Chyi Yen; Frank Q Ye; Michal Komlosh; Peter J Basser
Journal:  Neuroimage       Date:  2021-11-25       Impact factor: 6.556

3.  Repeatability and reproducibility of prospective motion- and shim corrected 2D glycoCEST MRI.

Authors:  Gizeaddis Lamesgin Simegn; Ali Alhamud; Andre J W van der Kouwe; Ernesta Meintjes; Frances Robertson
Journal:  Quant Imaging Med Surg       Date:  2019-10

4.  Whole-Brain Imaging of Subvoxel T1-Diffusion Correlation Spectra in Human Subjects.

Authors:  Alexandru V Avram; Joelle E Sarlls; Peter J Basser
Journal:  Front Neurosci       Date:  2021-06-11       Impact factor: 4.677

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.