Literature DB >> 20663396

Restenosis after stent placement for ostial stenosis of vertebral artery.

S Kogure1, N Sakai, K Iihara, H Sakai, H Sakaida, T Higashi, J C Takahashi, H Ohta, T Nagamine, R Anei, A Soeda, A Taniguchi, I Nagata.   

Abstract

SUMMARY: The purpose of this study was to evaluate our initial procedural success rate and angiographical outcome of stent placement for vertebral artery (VA) stenosis at the intermediate followup period (11.3 +/- 7.3 months). Stent placement was successfully performed in 20 procedures (19 patients), resulting in a marked reduction of stenosis from 78.7 +/- 12.6 % before to 8.7% +/- 10.6 after stenting. Follow-up angiography, performed after an interval of 11.3 +/- 7.3 months, revealed restenosis greater than 50% in a total of 6 procedures (40%) out of 15. Although PTA with stent placement for stenosis affecting VA origin provided excellent initial success, restenosis occurred at a significant rate even during the intermediate follow-up period.

Entities:  

Year:  2002        PMID: 20663396      PMCID: PMC3627237          DOI: 10.1177/15910199010070S125

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  8 in total

1.  Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent.

Authors:  Y Kobayashi; J De Gregorio; N Kobayashi; B Reimers; R Albiero; M Vaghetti; L Finci; C Di Mario; A Colombo
Journal:  Am J Cardiol       Date:  1999-09-01       Impact factor: 2.778

2.  Embolism from vertebral artery origin occlusive disease.

Authors:  L R Caplan; P Amarenco; A Rosengart; E F Lafranchise; P A Teal; M Belkin; L D DeWitt; M S Pessin
Journal:  Neurology       Date:  1992-08       Impact factor: 9.910

3.  Proximal extracranial vertebral artery disease in the New England Medical Center Posterior Circulation Registry.

Authors:  R J Wityk; H M Chang; A Rosengart; W C Han; L D DeWitt; M S Pessin; L R Caplan
Journal:  Arch Neurol       Date:  1998-04

4.  Extracranial vertebral artery stent placement: in-hospital and follow-up results.

Authors:  H D Chastain; M S Campbell; S Iyer; G S Roubin; J Vitek; A Mathur; N A Al-Mubarak; J B Terry; V Yates; K Kretzer; D Alred; C R Gomez
Journal:  J Neurosurg       Date:  1999-10       Impact factor: 5.115

5.  Vertebral artery stenting following percutaneous transluminal angioplasty. Technical note.

Authors:  G S Storey; M P Marks; M Dake; A M Norbash; G K Steinberg
Journal:  J Neurosurg       Date:  1996-05       Impact factor: 5.115

6.  Comparison of balloon angioplasty versus debulking devices versus stenting in right coronary ostial lesions.

Authors:  S P Jain; M W Liu; L S Dean; R Babu; C M Goods; J S Yadav; K F Al-Shaibi; A Mathur; S S Iyer; J M Parks; W A Baxley; G S Roubin
Journal:  Am J Cardiol       Date:  1997-05-15       Impact factor: 2.778

7.  Percutaneous transluminal angioplasty and stenting of the proximal vertebral artery for symptomatic stenosis.

Authors:  M Piotin; L Spelle; J B Martin; A Weill; G Rancurel; I B Ross; D A Rüfenacht; J Chiras
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

8.  Multicenter study of percutaneous transluminal angioplasty for right coronary artery ostial stenosis.

Authors:  E J Topol; S G Ellis; J Fishman; P Leimgruber; R K Myler; S H Stertzer; W W O'Neill; J S Douglas; G S Roubin; S B King
Journal:  J Am Coll Cardiol       Date:  1987-06       Impact factor: 24.094

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.