Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent.

Y Kobayashi1, J De Gregorio, N Kobayashi, B Reimers, R Albiero, M Vaghetti, L Finci, C Di Mario, A Colombo.   

Abstract

The intrinsic characteristics of a stent including stent length may affect both procedural success and long-term outcome. The present study evaluated the immediate and follow-up results after implantation of the short and long NIR stent and compared these results with the Palmaz-Schatz stent. Between July 1995 and December 1996, stenting with a 16-mm NIR stent (NIR-16), a 32-mm NIR stent (NIR-32), or a Palmaz-Schatz stent (PS) was performed in 68, 57, and 155 lesions, respectively. There were no significant differences in the incidences of delivery failure (PS, 2.6%: NIR-16, 4.4%; NIR-32, 5.3%; p = NS) and procedural success (PS, 92%; NIR-16, 93%; NIR-32, 93%; p = NS) among the 3 groups. The reference vessel diameter was smaller in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz stent (PS, 3.14+/-0.58, NIR-16, 3.00+/-0.50; NIR-32, 2.90+/-0.47 mm; p <0.05). The lesion length was longer in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 8.9+/-5.0; NIR-16, 11.0+/-4.1; NIR-32, 26.1+/-9.7 mm; p <0.01). After the procedure, the lesions with a 32-mm NIR stent had a smaller minimal lumen diameter than those with a Palmaz-Schatz stent (PS, 3.17+/-0.61; NIR-16, 2.99+/-0.51; NIR-32, 2.89+/-0.49 mm; p <0.01). At follow-up, a smaller minimal lumen diameter was observed in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 2.32+/-0.98; NIR-16, 2.25+/-0.80; NIR-32, 1.68+/-0.79 mm; p <0.01). Restenosis rates were 16.5% in lesions with a Palmaz-Schatz stent, 13.3% in those with a 16-mm NIR stent, and 47.4% in those with a 32-mm NIR stent (p <0.01). Although stent delivery and procedural success of a long NIR stent were acceptable, the restenosis rate of a long NIR stent was high compared with a short NIR stent or a Palmaz-Schatz stent.

Entities:  

Mesh:

Year:  1999        PMID: 10482144     DOI: 10.1016/s0002-9149(99)00366-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  1 in total

1.  Restenosis after stent placement for ostial stenosis of vertebral artery.

Authors:  S Kogure; N Sakai; K Iihara; H Sakai; H Sakaida; T Higashi; J C Takahashi; H Ohta; T Nagamine; R Anei; A Soeda; A Taniguchi; I Nagata
Journal:  Interv Neuroradiol       Date:  2002-01-10       Impact factor: 1.610

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.