Literature DB >> 20632010

[Functional results with two multifocal intraocular lenses with different near addition].

U Mester1, B Junker, H Kaymak.   

Abstract

BACKGROUND: The reduction of the near addition of multifocal intraocular lenses from +4 D to +3 D should improve the visual function in the intermediate distance. The ReSTOR +3 D is a multifocal lens with a near addition of 3 D. PATIENTS AND METHODS: In a prospective study the new ReSTOR +3 D was compared to the former ReSTOR platform with 4 D near addition. A total of 40 patients received 1 of these 2 multifocal lenses bilaterally in both eyes after uneventful phacoemulsification in otherwise sound cataract eyes (20 patients ReSTOR +3 D, 20 patients ReSTOR + 4D). After 3 months the following parameters were assessed: uncorrected and corrected distance visual acuity, near vision at different distances, contrast sensitivity, defocus curve and anterior and posterior segments. The functional tests were performed monocularly and binocularly.
RESULTS: Uncorrected binocular distance visual acuity (decimal) was 0.93 (logMAR 0.03 ± 0.12) in the ReSTOR +3 D group and 1.05 (-0.02 ± 0.1) in the ReSTOR +4 D group. In the intermediate distance the ReSTOR +3 D performed slightly better at 40 cm (0.68 versus 0.56) (logMAR 0.17 ± 0.14 versus 0.24 ± 0.18). The difference was significant (p<0.01) at 70 cm (0.69 versus 0.43) (logMAR 0.16 ± 0.27 vs 0.37 ± 0.2). The superior performance of the ReSTOR +3 D in the intermediate distance was also clearly visible in the defocus curves. All functional tests revealed significantly better results when performed binocularly.
CONCLUSION: The ReSTOR +3 D multifocal intraocular lens performed significantly better in the intermediate distance compared to the ReSTOR +4 D. The other functional tests showed excellent and equal results with both lenses. The reduction of near addition does not increase dysphotopsia, particularly halos. Complaints of unsatisfactory vision in the intermediate distance were reported only by patients with the ReSTOR +4 D. The new ReSTOR +3 D is likely to improve the acceptance of multifocal intraocular lenses.

Entities:  

Mesh:

Year:  2011        PMID: 20632010     DOI: 10.1007/s00347-010-2220-x

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  20 in total

1.  Prospective study of the Acri.LISA bifocal intraocular lens.

Authors:  José F Alfonso; Luis Fernández-Vega; Ana Señaris; Robert Montés-Micó
Journal:  J Cataract Refract Surg       Date:  2007-11       Impact factor: 3.351

2.  Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial.

Authors:  Carlos E Souza; Cristina Muccioli; Eduardo S Soriano; Maria Regina Chalita; Filipi Oliveira; Lincoln L Freitas; Luci P Meire; Celina Tamaki; Rubens Belfort
Journal:  Am J Ophthalmol       Date:  2006-03-20       Impact factor: 5.258

3.  Visual performance of patients with bilateral vs combination Crystalens, ReZoom, and ReSTOR intraocular lens implants.

Authors:  Jay S Pepose; Mujtaba A Qazi; James Davies; John F Doane; James C Loden; Varunan Sivalingham; Ashraf M Mahmoud
Journal:  Am J Ophthalmol       Date:  2007-07-25       Impact factor: 5.258

4.  All-distance visual acuity in eyes with a nontinted or a yellow-tinted diffractive multifocal intraocular lens.

Authors:  Ken Hayashi; Miki Masumoto; Hideyuki Hayashi
Journal:  Jpn J Ophthalmol       Date:  2009-03-31       Impact factor: 2.447

Review 5.  [Presbyopia correction using intraocular lenses].

Authors:  M P Holzer; T M Rabsilber; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

6.  Clear lens extraction with multifocal apodized diffractive intraocular lens implantation.

Authors:  Luis Fernández-Vega; José F Alfonso; Pedro P Rodríguez; Robert Montés-Micó
Journal:  Ophthalmology       Date:  2007-03-13       Impact factor: 12.079

7.  [First results with a new aberration correcting bifocal intraocular lens].

Authors:  H Kaymak; U Mester
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

8.  [Prospective comparison of 2 multi-focal lens models].

Authors:  A Liekfeld; T Walkow; N Anders; D T Pham; J Wollensak
Journal:  Ophthalmologe       Date:  1998-04       Impact factor: 1.059

Review 9.  [Design and optical principles of multifocal lenses].

Authors:  G U Auffarth; T M Rabsilber; T Kohnen; M P Holzer
Journal:  Ophthalmologe       Date:  2008-06       Impact factor: 1.059

10.  [Subjective and objective outcome following implantation of the apodized diffractive AcrySof ReSTOR].

Authors:  K Petermeier; P Szurman
Journal:  Ophthalmologe       Date:  2007-05       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.