Literature DB >> 20617228

A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results.

Christel Larsson1, Per Vult von Steyern, Krister Nilner.   

Abstract

PURPOSE: The development of high-strength oxide ceramic materials has led to increased interest in all-ceramic fixed dental prostheses (FDPs). Success rates reported in clinical studies for all-ceramic FDPs based on high-strength oxide ceramic materials reportedly approach those of porcelain-fused-to-metal FDPs. These reconstructions, however, are still of limited size and have mainly concerned FDPs supported by natural teeth. The purpose of this study was to evaluate the clinical performance of multiunit all-ceramic FDPs supported by dental implants.
MATERIALS AND METHODS: Ten patients received mandibular yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) FDPs manufactured according to the Cercon technique and supported by four Astra Tech implants. Nine patients received 10-unit FDPs and one patient received a 9-unit FDP. The FDPs were cemented with Panavia F 2.0 onto individually prepared titanium abutments. The FDPs were evaluated at baseline and after 12, 24, and 36 months.
RESULTS: At the 3-year follow-up, all FDPs were in use, and all patients were fully satisfied with their treatment. None of the reconstructions had fractured. Superficial chip-off fractures of the veneering porcelain were, however, observed in nine patients (34 of 99 units, 34%).
CONCLUSION: Results from this 3-year study suggest that implant-supported full-arch Y-TZP FDPs manufactured according to the Cercon technique should be viewed as a treatment alternative cautiously. A better understanding of the factors resulting in chip-off fractures is needed, together with longer follow-up studies involving larger numbers of patients, before the material and technique can be recommended for general use.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20617228

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  15 in total

1.  Overview: Damage resistance of graded ceramic restorative materials.

Authors:  Yu Zhang
Journal:  J Eur Ceram Soc       Date:  2012-08-01       Impact factor: 5.302

2.  Sliding contact fatigue of graded zirconia with external esthetic glass.

Authors:  L Ren; M N Janal; Y Zhang
Journal:  J Dent Res       Date:  2011-06-10       Impact factor: 6.116

3.  Clinical performance of screw-retained and cemented implant-supported zirconia single crowns: 36-month results.

Authors:  Claudio Cacaci; Friederike Cantner; Thomas Mücke; Peter Randelzhofer; Jan Hajtó; Florian Beuer
Journal:  Clin Oral Investig       Date:  2016-10-29       Impact factor: 3.573

4.  Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report.

Authors:  Kwantae Noh; Woo-Jin Choi; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

5.  A fractographic study of clinically retrieved zirconia-ceramic and metal-ceramic fixed dental prostheses.

Authors:  Zhen Pang; Asima Chughtai; Irena Sailer; Yu Zhang
Journal:  Dent Mater       Date:  2015-07-29       Impact factor: 5.304

Review 6.  Dental Ceramics for Restoration and Metal Veneering.

Authors:  Yu Zhang; J Robert Kelly
Journal:  Dent Clin North Am       Date:  2017-10

7.  Edge chipping and flexural resistance of monolithic ceramics.

Authors:  Yu Zhang; James J-W Lee; Ramanathan Srikanth; Brian R Lawn
Journal:  Dent Mater       Date:  2013-10-17       Impact factor: 5.304

8.  Residual stresses in porcelain-veneered zirconia prostheses.

Authors:  Marta Baldassarri; Christian F J Stappert; Mark S Wolff; Van P Thompson; Yu Zhang
Journal:  Dent Mater       Date:  2012-05-11       Impact factor: 5.304

9.  Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report.

Authors:  Ramtin Sadid-Zadeh; Perng-Ru Liu; Ruth Aponte-Wesson; Sandra J O'Neal
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

10.  Rationale for the use of CAD/CAM technology in implant prosthodontics.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  Int J Dent       Date:  2013-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.