The median filter as a preprocessor for a patient monitor limit alarm system in intensive care.

A Mäkivirta1, E Koski, A Kari, T Sukuvaara.   

Abstract

We studied the effects of removing brief variations in the monitoring data on the quality of limit alarms during the postoperative haemodynamic monitoring of cardiac patients. The variations were removed by median filtering. The false alarm frequency was reduced by more than two-thirds compared with a typical patient monitor. We designed and clinically tested a novel dual-limit alarm system with two median filters. The proportion of true alarms increased from 12% to 49% as compared to a typical patient monitor. The average false alarm frequency was 4.5 alarms per monitored hour. No correct alarms were missed.

Entities:  

Mesh:

Year:  1991        PMID: 2060287     DOI: 10.1016/0169-2607(91)90039-v

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  26 in total

1.  Building ICU artifact detection models with more data in less time.

Authors:  C L Tsien; I S Kohane; N McIntosh
Journal:  Proc AMIA Symp       Date:  2001

2.  Extraction of a local linear trend from physiological time series.

Authors:  Roland Fried; Ursula Gather; Michael Imhoff
Journal:  AMIA Annu Symp Proc       Date:  2003

3.  Reduction of clinically irrelevant alarms in patient monitoring by adaptive time delays.

Authors:  Felix Schmid; Matthias S Goepfert; Frank Franz; David Laule; Beate Reiter; Alwin E Goetz; Daniel A Reuter
Journal:  J Clin Monit Comput       Date:  2015-11-30       Impact factor: 2.502

4.  Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.

Authors:  W Zong; G B Moody; R G Mark
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

5.  Individual and joint expert judgments as reference standards in artifact detection.

Authors:  Marion Verduijn; Niels Peek; Nicolette F de Keizer; Erik-Jan van Lieshout; Anne-Cornelie J M de Pont; Marcus J Schultz; Evert de Jonge; Bas A J M de Mol
Journal:  J Am Med Inform Assoc       Date:  2007-12-20       Impact factor: 4.497

6.  Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.

Authors:  A T Rheineck-Leyssius; C J Kalkman
Journal:  J Clin Monit Comput       Date:  1998-04       Impact factor: 2.502

7.  An expert system for monitor alarm integration.

Authors:  C Oberli; J Urzua; C Saez; M Guarini; A Ciprianio; B Garayar; G Lema; R Canessa; C Sacco; M Irarrazaval
Journal:  J Clin Monit Comput       Date:  1999-01       Impact factor: 2.502

8.  Arterial blood pressure during early sepsis and outcome.

Authors:  Martin W Dünser; Jukka Takala; Hanno Ulmer; Viktoria D Mayr; Günter Luckner; Stefan Jochberger; Fritz Daudel; Philipp Lepper; Walter R Hasibeder; Stephan M Jakob
Journal:  Intensive Care Med       Date:  2009-02-03       Impact factor: 17.440

9.  Robust parameter extraction for decision support using multimodal intensive care data.

Authors:  G D Clifford; W J Long; G B Moody; P Szolovits
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2009-01-28       Impact factor: 4.226

10.  Hemodynamic variables and mortality in cardiogenic shock: a retrospective cohort study.

Authors:  Christian Torgersen; Christian A Schmittinger; Sarah Wagner; Hanno Ulmer; Jukka Takala; Stephan M Jakob; Martin W Dünser
Journal:  Crit Care       Date:  2009-10-02       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.