Literature DB >> 20599012

Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis.

Apostolos Tzikas1, Nicolo Piazza, Marcel L Geleijnse, Nicolas Van Mieghem, Rutger-Jan Nuis, Carl Schultz, Robert-Jan van Geuns, Tjebbe W Galema, Arie-Pieter Kappetein, Patrick W Serruys, Peter P de Jaegere.   

Abstract

A prosthesis-patient mismatch (PPM) is present when the prosthetic valve is too small in relation to the patient's body size. The purpose of the present study was to investigate the frequency of PPM after the implantation of the Medtronic CoreValve System, and its relation to the clinical outcome. The indexed effective orifice area (EOA) was measured in 74 patients with symptomatic severe aortic stenosis, who had undergone successful transcatheter aortic valve implantation with the Medtronic CoreValve System, at baseline and discharge. PPM was defined as severe (indexed EOA <0.65 cm(2)/m(2)) or moderate (indexed EOA 0.65 to 0.85 cm(2)/m(2)). The indexed EOA increased from 0.35 +/- 0.13 to 0.97 +/- 0.34 cm(2)/m(2) after transcatheter aortic valve implantation (p <0.001) and was accompanied by significant clinical improvement. Severe and moderate PPMs were found in 16% and 23% of patients, respectively. Patients with severe PPM were more symptomatic and had a smaller indexed EOA at baseline than those with moderate or no PPM (0.28 +/- 0.09 vs 0.36 +/- 0.12 cm(2)/m(2), p <0.05). Functional status and mortality at 30 days and 6 months was not significantly different between the patients with severe PPM and those with moderate or no PPM. In conclusion, the indexed EOA increased significantly after transcatheter aortic valve implantation. Severe PPM was observed in 16% of the patients and was not associated with the clinical outcome. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20599012     DOI: 10.1016/j.amjcard.2010.02.036

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  13 in total

1.  Transcatheter resection of the native aortic valve prior to endovalve implantation - A rational approach to reduce TAVI-induced complications.

Authors:  Parla Astarci; Pierre-Yves Etienne; Benoit Raucent; Xavier Bollen; Kahn Tranduy; David Glineur; Laurent Dekerchove; Philippe Noirhomme; Gébrine Elkhoury
Journal:  Ann Cardiothorac Surg       Date:  2012-07

2.  Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis.

Authors:  Philippe Pibarot; Neil J Weissman; William J Stewart; Rebecca T Hahn; Brian R Lindman; Thomas McAndrew; Susheel K Kodali; Michael J Mack; Vinod H Thourani; D Craig Miller; Lars G Svensson; Howard C Herrmann; Craig R Smith; Josep Rodés-Cabau; John Webb; Scott Lim; Ke Xu; Irene Hueter; Pamela S Douglas; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2014-09-30       Impact factor: 24.094

Review 3.  Transcatheter Aortic Valve Implantation in Small Anatomy: Patient Selection and Technical Challenges.

Authors:  Makoto Nakashima; Yusuke Watanabe
Journal:  Interv Cardiol       Date:  2018-05

4.  Clinical impact of a new left bundle branch block following TAVI implantation: 1-year results of the TAVIK cohort.

Authors:  Gerhard Schymik; Panagiotis Tzamalis; Peter Bramlage; Martin Heimeshoff; Alexander Würth; Rainer Wondraschek; Bernd-Dieter Gonska; Herbert Posival; Claus Schmitt; Holger Schröfel; Armin Luik
Journal:  Clin Res Cardiol       Date:  2014-11-12       Impact factor: 5.460

5.  Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

Authors:  Cristina da Silva; Anders Sahlen; Reidar Winter; Magnus Bäck; Andreas Rück; Magnus Settergren; Aristomenis Manouras; Kambiz Shahgaldi
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-08       Impact factor: 2.357

Review 6.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

7.  Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up.

Authors:  Dong Zhao; Chunsheng Wang; Tao Hong; Cuizhen Pan; Changfa Guo
Journal:  J Cardiothorac Surg       Date:  2012-09-21       Impact factor: 1.637

8.  Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation - predictors, incidence and impact on clinical efficacy. A preliminary study.

Authors:  Karol Zbroński; Bartosz Rymuza; Piotr Scisło; Kajetan Grodecki; Paulina Dobkowska; Marek Wawrzacz; Radosław Wilimski; Anna Słowikowska; Janusz Kochman; Krzysztof J Filipiak; Grzegorz Opolski; Zenon Huczek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2017-11-29       Impact factor: 1.426

Review 9.  Functional status and quality of life after transcatheter aortic valve replacement: a systematic review.

Authors:  Caroline A Kim; Suraj P Rasania; Jonathan Afilalo; Jeffrey J Popma; Lewis A Lipsitz; Dae Hyun Kim
Journal:  Ann Intern Med       Date:  2014-02-18       Impact factor: 25.391

10.  Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Authors:  Yan-Biao Liao; Yi-Jian Li; Li Jun-Li; Zhen-Gang Zhao; Xin Wei; Jiay-Yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.