Comparison of accuracy of intraocular lens calculations using automated keratometry, a Placido-based corneal topographer, and a combined Placido-based and dual Scheimpflug corneal topographer.

Mariko Shirayama1, Li Wang, Douglas D Koch, Mitchell P Weikert.   

Abstract

PURPOSE: To compare the accuracy of intraocular lens (IOL) power calculations with automated keratometry, a Placido-based corneal topographer, and a combined Placido-based and dual Scheimpflug corneal topographer.
METHODS: Retrospectively, 75 eyes of 62 patients who had phacoemulsification with implantation of the SN60WF IOL were analyzed. Corneal powers were measured using 5 techniques: (1) automated keratometry (AutoK, IOL Master), (2) simulated keratometry from the Placido-based corneal topographer (SimKP, Atlas), (3) simulated keratometry from the combined Placido-based and dual Scheimpflug corneal topographer (SimKP+DS, Galilei), (4) total corneal power of the steep and flat meridians over a central 1.0-4.0 mm zone using ray tracing (TCPMeridian, Galilei), and (5) TCP over the central 4.0-mm zone by ray tracing (TCPCentral, Galilei). For each IOL implanted, prediction errors were determined by comparing the predicted refractions calculated with the Holladay 1 formula to the actual refraction that was obtained 3-4 weeks postoperatively. The surgeon factor was optimized for each method of corneal power measurement. The accuracy of IOL power calculation using these corneal powers was determined by calculating the mean absolute prediction error (MAE) and the percentage of eyes with prediction errors within 0.5, 1.0, and 1.5 diopters (D). RESULT: The MAEs were 0.37, 0.39, 0.39, 0.41, and 0.42 D for the AutoK, SimKP, SimKP+DS, TCPMeridian, and TCPCentral methods, respectively. There were no significant differences among groups. Over 93% of eyes had MAEs within 1.0 D for all methods of corneal power measurement.
CONCLUSIONS: The accuracy of IOL power calculation was comparable with AutoK, the Placido-based corneal topographer, and the combined Placido-based and dual Scheimpflug corneal topographer.

Entities:  

Mesh:

Year:  2010        PMID: 20595893     DOI: 10.1097/ICO.0b013e3181d3d689

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  9 in total

1.  Precision of 5 different keratometry devices.

Authors:  Jonas Vejvad Nørskov Laursen; Peter Jeppesen; Thomas Olsen
Journal:  Int Ophthalmol       Date:  2015-03-29       Impact factor: 2.031

2.  Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

Authors:  Ahmet Kirgiz; Kurşat Atalay; Havva Kaldirim; Kubra Serefoglu Cabuk; Mehmet Orcun Akdemir; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2016-09-01       Impact factor: 2.031

3.  Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

Authors:  David Huang; Maolong Tang; Li Wang; Xinbo Zhang; Rebecca L Armour; Devin M Gattey; Lorinna H Lombardi; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

4.  Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging.

Authors:  Giacomo Savini; Leonardo Taroni; Domenico Schiano-Lomoriello; Kenneth J Hoffer
Journal:  Eye (Lond)       Date:  2020-11-02       Impact factor: 4.456

5.  Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer.

Authors:  Zeynep Altıparmak; Ramazan Yağcı; Emre Güler; Zeynel Arslanyılmaz; Metin Canbal; İbrahim F Hepşen
Journal:  Turk J Ophthalmol       Date:  2015-12-05

6.  Comparison of Conventional Keratometry and Total Keratometry in Normal Eyes.

Authors:  Rie Hoshikawa; Kazutaka Kamiya; Fusako Fujimura; Nobuyuki Shoji
Journal:  Biomed Res Int       Date:  2020-04-13       Impact factor: 3.411

7.  A Multicenter Study of the Distribution Pattern of Posterior-To-Anterior Corneal Curvature Radii Ratio in Chinese Myopic Patients.

Authors:  Changting Tang; Qiaowei Wu; Baoyi Liu; Guanrong Wu; Jing Fan; Yijun Hu; Honghua Yu
Journal:  Front Med (Lausanne)       Date:  2021-12-20

8.  Clinical evaluation of ocular biometry of dual Scheimpflug analyzer, GALILEI G6 and swept source optical coherence tomography, ANTERION.

Authors:  Boonsong Wanichwecharungruang; Anyarak Amornpetchsathaporn; Kittipong Kongsomboon; Wisakorn Wongwijitsook; Kornkamol Annopawong; Somporn Chantra
Journal:  Sci Rep       Date:  2022-03-04       Impact factor: 4.379

9.  Relationship between Axial Length and Corneo-Scleral Topography: A Preliminary Study.

Authors:  Laurent Bataille; Ainhoa Molina-Martín; David P Piñero
Journal:  Diagnostics (Basel)       Date:  2021-03-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.