Literature DB >> 20580193

Ceramic-on-ceramic hip outcome at a 5- to 10-year interval: has it lived up to its expectations?

J Wesley Mesko1, James A D'Antonio, William N Capello, Benjamin E Bierbaum, Marybeth Naughton.   

Abstract

This study reports revision and complication rates of a single cementless double-wedged tapered stem with an alumina-alumina bearing over 10 years since the beginning of premarket clinical trials. Of 930 hips (848 patients) implanted by 9 surgeons, there were 19 revisions at mean follow-up of 5.9 years compared to 10 revisions in the 123 hips implanted with the polyethylene control group at mean 7.8 years. The ongoing safety of alumina-alumina bearings is demonstrated through excellent (96.8%) survivorship at 10 years. Twenty-one patients reported 23 incidences of noise described as clicking, squeaking, popping, or creaking. Eight patients with 9 hips described the noise as squeaking, most occurring rarely and only 1 occurring frequently in a patient subsequently revised for a reason aside from the squeaking.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20580193     DOI: 10.1016/j.arth.2010.04.029

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.

Authors:  Jaime A Carvajal Alba; Marcella E Elpers; Andrew E Rosenberg; Raymond P Robinson
Journal:  HSS J       Date:  2015-05-27

2.  No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial.

Authors:  C Anderson Engh; Supatra Sritulanondha; Abigail Korczak; Terrence David Whalen; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

3.  Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients.

Authors:  Tae-Hun Lee; Young-Wan Moon; Seung-Jae Lim; Youn-Soo Park
Journal:  Hip Pelvis       Date:  2014-06-30

4.  [Which hip articulation bearing for which patient? : Tribology of the future].

Authors:  M M Morlock; N Bishop; C Kaddick
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

5.  Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

Authors:  Cathal J McCarthy; John Mahon; Gerard A Sheridan; Adanna Welch-Phillips; John M O'Byrne; Paddy J Kenny
Journal:  J Clin Orthop Trauma       Date:  2022-07-06

Review 6.  How have alternative bearings and modularity affected revision rates in total hip arthroplasty?

Authors:  William M Mihalko; Markus A Wimmer; Carol A Pacione; Michel P Laurent; Robert F Murphy; Carson Rider
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

7.  Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials.

Authors:  Dongcai Hu; Kai Tie; Xiao Yang; Yang Tan; Mohammed Alaidaros; Liaobin Chen
Journal:  J Orthop Surg Res       Date:  2015-02-03       Impact factor: 2.359

Review 8.  Ten-year survival of ceramic-on-ceramic total hip arthroplasty in patients younger than 60 years: a systematic review and meta-analysis.

Authors:  Ihab Ibraheam El-Desouky; Albaraa Hassan Helal; Ali Mohamed Reda Mansour
Journal:  J Orthop Surg Res       Date:  2021-11-18       Impact factor: 2.359

9.  Fracture of ceramic liner and head in a total hip arthroplasty with a sandwich type cup.

Authors:  Diego Reátegui; Sebastián García; Guillem Bori; Xavier Gallart
Journal:  Case Rep Orthop       Date:  2013-04-18

Review 10.  Total hip replacement for the treatment of end stage arthritis of the hip: a systematic review and meta-analysis.

Authors:  Alexander Tsertsvadze; Amy Grove; Karoline Freeman; Rachel Court; Samantha Johnson; Martin Connock; Aileen Clarke; Paul Sutcliffe
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.