Literature DB >> 20576008

Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders.

Christian Fenger-Eriksen1, Gary W Moore, Savita Rangarajan, Jørgen Ingerslev, Benny Sørensen.   

Abstract

BACKGROUND: Measurement of plasma fibrinogen is often required in critically ill patients or massively bleeding patients being resuscitated with colloid plasma expander. This study aimed at evaluating different assays of plasma fibrinogen after in vitro dilution with commonly used plasma expanders and challenged the hypothesis that levels of fibrinogen are estimated significantly higher in plasma diluted with colloid plasma expander compared with isotonic saline. STUDY DESIGN AND METHODS: Fibrinogen measurements were established in plasma samples each diluted in vitro to 30 or 50% with isotonic saline, hydroxyethyl starch (HES) 130/0.4, and human albumin. Fibrinogen levels were assessed using an antigen determination, three photo-optical Clauss methods, one mechanical Clauss method, a prothrombin-derived method, and viscoelastic measurement through thromboelastometry.
RESULTS: Measurement of fibrinogen levels was significantly different when performed on alternate analytical platforms. By 30 and 50% dilution with HES 130/0.4 coagulation analyzers using the photo-optical Clauss methods significantly overestimated levels of fibrinogen. Dilution with human albumin did not affect fibrinogen levels except from one analyzer by 50% dilution level. Viscoelastic measurement of fibrin polymerization was reduced at both dilution levels and appeared to reflect the impairment of fibrin polymerization induced by HES 130/0.4 and to a lesser extent human albumin.
CONCLUSION: This study demonstrated that different automated coagulation analyzers revealed significantly different levels of fibrinogen. The presence of colloid plasma expander gave rise to erroneous high levels of fibrinogen returned from some coagulation analyzers employing the method of Clauss.
© 2010 American Association of Blood Banks.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20576008     DOI: 10.1111/j.1537-2995.2010.02752.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  22 in total

1.  Cryoprecipitate use in the PROMMTT study.

Authors:  John B Holcomb; Erin E Fox; Xuan Zhang; Nathan White; Charles E Wade; Bryan A Cotton; Deborah J del Junco; Eileen M Bulger; Mitchell J Cohen; Martin A Schreiber; John G Myers; Karen J Brasel; Herb A Phelan; Louis H Alarcon; Peter Muskat; Mohammad H Rahbar
Journal:  J Trauma Acute Care Surg       Date:  2013-07       Impact factor: 3.313

2.  Fibrinogen concentrate improves survival during limited resuscitation of uncontrolled hemorrhagic shock in a Swine model.

Authors:  Nathan J White; Xu Wang; Conrad Liles; Susan Stern
Journal:  Shock       Date:  2014-11       Impact factor: 3.454

3.  The use of viscoelastic haemostatic assays in non-cardiac surgical settings: a systematic review and meta-analysis.

Authors:  Raimondo De Cristofaro
Journal:  Blood Transfus       Date:  2018-03-05       Impact factor: 3.443

4.  [Early viscoelasticity-based coagulation therapy for severely injured bleeding patients: Report of the consensus group on the consensus conference 2014 for formulation of S2k guidelines].

Authors:  M Maegele; K Inaba; S Rizoli; P Veigas; J Callum; R Davenport; M Fröhlich; J Hess
Journal:  Anaesthesist       Date:  2015-10       Impact factor: 1.041

5.  Management of Dilutional Coagulopathy during Pediatric Major Surgery.

Authors:  Thorsten Haas; Jacqueline Mauch; Markus Weiss; Markus Schmugge
Journal:  Transfus Med Hemother       Date:  2012-03-08       Impact factor: 3.747

6.  Comparison of Two Different Fibrinogen Concentrates in an in vitro Model of Dilutional Coagulopathy.

Authors:  Philipp Groene; Tobias Wiederkehr; Tobias Kammerer; Patrick Möhnle; Melanie Maerte; Andreas Bayer; Klaus Görlinger; Markus Rehm; Simon T Schäfer
Journal:  Transfus Med Hemother       Date:  2019-08-16       Impact factor: 3.747

7.  Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used.

Authors:  Jose Mateo; Pilar Paniagua; Tobias Koller; Victoria Moral; Jordi Fontcuberta
Journal:  Crit Care       Date:  2011-09-12       Impact factor: 9.097

8.  FIBTEM provides early prediction of massive transfusion in trauma.

Authors:  Herbert Schöchl; Bryan Cotton; Kenji Inaba; Ulrike Nienaber; Henrik Fischer; Wolfgang Voelckel; Cristina Solomon
Journal:  Crit Care       Date:  2011-11-11       Impact factor: 9.097

Review 9.  Early and individualized goal-directed therapy for trauma-induced coagulopathy.

Authors:  Herbert Schöchl; Marc Maegele; Cristina Solomon; Klaus Görlinger; Wolfgang Voelckel
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-02-24       Impact factor: 2.953

Review 10.  Haemostatic monitoring during postpartum haemorrhage and implications for management.

Authors:  C Solomon; R E Collis; P W Collins
Journal:  Br J Anaesth       Date:  2012-10-16       Impact factor: 9.166

View more