Literature DB >> 20574989

Rapid multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart.

Angus Z Lau1, Albert P Chen, Nilesh R Ghugre, Venkat Ramanan, Wilfred W Lam, Kim A Connelly, Graham A Wright, Charles H Cunningham.   

Abstract

Hyperpolarization of spins via dynamic nuclear polarization (DNP) has been explored as a method to non-invasively study real-time metabolic processes occurring in vivo using (13)C-labeled substrates. Recently, hyperpolarized (13)C pyruvate has been used to characterize in vivo cardiac metabolism in the rat and pig. Conventional 3D spectroscopic imaging methods require in excess of 100 excitations, making it challenging to acquire a full cardiac-gated, breath-held, whole-heart volume. In this article, the development of a rapid multislice cardiac-gated spiral (13)C imaging pulse sequence consisting of a large flip-angle spectral-spatial excitation RF pulse combined with a single-shot spiral k-space trajectory for rapid imaging of cardiac metabolism is described. This sequence permits whole-heart coverage (6 slices, 8.8-mm in-plane resolution) in any plane, allowing imaging of the metabolites of interest, [1-(13)C] pyruvate, [1-(13)C] lactate, and (13)C bicarbonate, within a single breathhold. Pyruvate and bicarbonate cardiac volumes were acquired, while lactate images were not acquired due to low lactate levels in the animal model studied. The sequence was demonstrated with phantom experiments and in vivo testing in a pig model.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20574989     DOI: 10.1002/mrm.22525

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  74 in total

1.  A method for simultaneous echo planar imaging of hyperpolarized ¹³C pyruvate and ¹³C lactate.

Authors:  Galen D Reed; Peder E Z Larson; Cornelius von Morze; Robert Bok; Michael Lustig; Adam B Kerr; John M Pauly; John Kurhanewicz; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2012-02-24       Impact factor: 2.229

2.  Application of hyperpolarized [1-¹³C]lactate for the in vivo investigation of cardiac metabolism.

Authors:  Dirk Mayer; Yi-Fen Yen; Sonal Josan; Jae Mo Park; Adolf Pfefferbaum; Ralph E Hurd; Daniel M Spielman
Journal:  NMR Biomed       Date:  2012-01-25       Impact factor: 4.044

3.  Flux through hepatic pyruvate carboxylase and phosphoenolpyruvate carboxykinase detected by hyperpolarized 13C magnetic resonance.

Authors:  Matthew E Merritt; Crystal Harrison; A Dean Sherry; Craig R Malloy; Shawn C Burgess
Journal:  Proc Natl Acad Sci U S A       Date:  2011-11-07       Impact factor: 11.205

4.  Speeding up dynamic spiral chemical shift imaging with incoherent sampling and low-rank matrix completion.

Authors:  Stephen J DeVience; Dirk Mayer
Journal:  Magn Reson Med       Date:  2016-02-24       Impact factor: 4.668

5.  Development of high resolution 3D hyperpolarized carbon-13 MR molecular imaging techniques.

Authors:  Eugene Milshteyn; Cornelius von Morze; Galen D Reed; Hong Shang; Peter J Shin; Zihan Zhu; Hsin-Yu Chen; Robert Bok; Andrei Goga; John Kurhanewicz; Peder E Z Larson; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2017-01-07       Impact factor: 2.546

6.  Kinetic Analysis of Hepatic Metabolism Using Hyperpolarized Dihydroxyacetone.

Authors:  Alexander Kirpich; Mukundan Ragavan; James A Bankson; Lauren M McIntyre; Matthew E Merritt
Journal:  J Chem Inf Model       Date:  2019-01-15       Impact factor: 4.956

Review 7.  Strategies for rapid in vivo 1H and hyperpolarized 13C MR spectroscopic imaging.

Authors:  Sarah J Nelson; Eugene Ozhinsky; Yan Li; Il woo Park; Jason Crane
Journal:  J Magn Reson       Date:  2013-02-08       Impact factor: 2.229

Review 8.  Hyperpolarized 13C MRI: State of the Art and Future Directions.

Authors:  Zhen J Wang; Michael A Ohliger; Peder E Z Larson; Jeremy W Gordon; Robert A Bok; James Slater; Javier E Villanueva-Meyer; Christopher P Hess; John Kurhanewicz; Daniel B Vigneron
Journal:  Radiology       Date:  2019-03-05       Impact factor: 11.105

9.  Application of Good's buffers to pH imaging using hyperpolarized (13)C MRI.

Authors:  Robert R Flavell; Cornelius von Morze; Joseph E Blecha; David E Korenchan; Mark Van Criekinge; Renuka Sriram; Jeremy W Gordon; Hsin-Yu Chen; Sukumar Subramaniam; Robert A Bok; Zhen J Wang; Daniel B Vigneron; Peder E Larson; John Kurhanewicz; David M Wilson
Journal:  Chem Commun (Camb)       Date:  2015-09-25       Impact factor: 6.222

Review 10.  Chemistry and biochemistry of 13C hyperpolarized magnetic resonance using dynamic nuclear polarization.

Authors:  Kayvan R Keshari; David M Wilson
Journal:  Chem Soc Rev       Date:  2013-12-20       Impact factor: 54.564

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.