Literature DB >> 20572142

2D and 3D radial multi-gradient-echo DCE MRI in murine tumor models with dynamic R*2-corrected R1 mapping.

Julien Vautier1, Melanie Heilmann, Christine Walczak, Joël Mispelter, Andreas Volk.   

Abstract

Dynamic contrast-enhanced MRI is extensively studied to define and evaluate biomarkers for early assessment of vasculature-targeting therapies. In this study, two-dimensional and three-dimensional radial multi-gradient-echo techniques for dynamic R*(2)-corrected R(1) mapping based on the spoiled gradient recalled signal equation were implemented and validated at 4.7 T. The techniques were evaluated on phantoms and on a respiratory motion animated tumor model. R(1) measurements were validated with respect to a standard inversion-recovery spin-echo sequence in a four-compartment phantom covering a range of relaxation rates typically found in tumor tissue. In the range of [0.4, 3] sec(-1), R(1) differences were less than 10% for both two-dimensional and three-dimensional experiments. A dynamic contrast-enhanced MRI pilot study was performed on a colorectal tumor model subcutaneously implanted in mice at the abdominal level. Low motion sensitivity of radial acquisition allowed image recording without respiratory triggering. Three-dimensional K(trans) maps and significantly different mean K(trans) values were obtained for two contrast agents with different molecular weights. The radial multi-gradient-echo approach should be most useful for preclinical experimental conditions where the tissue of interest experiences physiologic motion, like spontaneous extracerebral tumors developed by transgenic mice, and where dynamic contrast-enhanced MRI is performed with high-relaxivity contrast agents. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20572142     DOI: 10.1002/mrm.22396

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

2.  An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence.

Authors:  Ergys Subashi; Kingshuk R Choudhury; G Allan Johnson
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Regularly incremented phase encoding - MR fingerprinting (RIPE-MRF) for enhanced motion artifact suppression in preclinical cartesian MR fingerprinting.

Authors:  Christian E Anderson; Charlie Y Wang; Yuning Gu; Rebecca Darrah; Mark A Griswold; Xin Yu; Chris A Flask
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

4.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.