Literature DB >> 20569728

BIVentricular versus right ventricular antitachycardia pacing to terminate ventricular tachyarrhythmias in patients receiving cardiac resynchronization therapy: the ADVANCE CRT-D Trial.

Maurizio Gasparini1, Frédéric Anselme, Jacques Clementy, Massimo Santini, José Martínez-Ferrer, Tiziana De Santo, Elisabetta Santi, Jeorg O Schwab.   

Abstract

BACKGROUND: This multicenter, prospective, randomized, controlled, parallel trial compares the efficacy of biventricular (BIV) versus right ventricular (RV) antitachycardia pacing (ATP) in terminating all kinds of ventricular tachycardia (VT).
METHODS: Five hundred twenty-six patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D) device were enrolled and randomized 1:1 to either BIV (266) or RV (260) ATP (single burst 8 pulse, 88% coupling interval) and were followed up for 12 months.
RESULTS: During 12 months' follow-up, 1,077 ventricular episodes in 180 patients were detected and classified: 634 true VTs divided into 69 ventricular fibrillation (VF) (11%), 202 fast ventricular tachycardia (FVT) (32%), and 363 VT (57%). A comparable first ATP efficacy (BIV 65% vs RV 68%, P = .59) was observed in FVT + VT, in VT zone (BIV 62% vs RV 71%, P = .25), and in FVT zone (BIV 71% vs RV 61%, P = .34). A trend toward lower accelerations during ATP applied to FVT was observed in the BIV group (3.5% BIV vs 10.2% RV, P = .163). No syncope/presyncope occurred during ATP for FVT in the BIV group versus 4 events (3.2%) in the RV group (P = .016). biventricular ATP was more effective in treating FVT in coronary artery disease (CAD) patients (P = .032), whereas both modalities presented similar efficacy in patients with non-CAD etiology (P = .549).
CONCLUSIONS: Antitachycardia pacing is effective in patients implanted with a CRT-D device. No significant differences in efficacy emerged between BIV- and RV-delivered ATP in the general population, whereas BIV ATP seems to present a safer profile in ischemic patients. Copyright 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20569728     DOI: 10.1016/j.ahj.2010.02.007

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  12 in total

1.  Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study.

Authors:  Jörg Otto Schwab; Hendrik Bonnemeier; Thomas Kleemann; Johannes Brachmann; Sven Fischer; Frank Birkenhauer; Frank Eberhardt
Journal:  Clin Res Cardiol       Date:  2015-05-23       Impact factor: 5.460

Review 2.  ICD programming.

Authors:  Mauro Biffi
Journal:  Indian Heart J       Date:  2013-12-20

3.  Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD.

Authors:  Alessandro Corzani; Matteo Ziacchi; Mauro Biffi; Igor Diemberger; Cristian Martignani; Giuseppe Boriani
Journal:  Indian Heart J       Date:  2015-02-12

Review 4.  New paradigms in the prevention of sudden cardiac arrest and heart failure treatment.

Authors:  Mustafa Dohadwala; N A Mark Estes; Mark S Link
Journal:  Curr Cardiol Rep       Date:  2011-10       Impact factor: 2.931

5.  Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences.

Authors:  Javier Jiménez-Candil; Olga Durán; Jean Núñez; Loreto Bravo; Jesús Hernández; Ana Martín-García; José Morínigo; Pedro L Sánchez
Journal:  J Interv Card Electrophysiol       Date:  2019-09-16       Impact factor: 1.900

6.  Conceptual Intra-Cardiac Electrode Configurations That Facilitate Directional Cardiac Stimulation for Optimal Electrotherapy.

Authors:  Adam Connolly; Steven Williams; Kawal Rhode; Christopher A Rinaldi; Martin J Bishop
Journal:  IEEE Trans Biomed Eng       Date:  2019-05       Impact factor: 4.538

Review 7.  Programming implantable cardioverter/defibrillators and outcomes.

Authors:  Fritz W Horlbeck; Joerg O Schwab
Journal:  F1000Prime Rep       Date:  2015-01-05

Review 8.  Optimal programming management of ventricular tachycardia storm in ICD patients.

Authors:  Zhiyong Qian; Jianghong Guo; Zhiyong Zhang; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  J Biomed Res       Date:  2015-01-05

9.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01

10.  Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction.

Authors:  Zhi-Wen Zhou; Kai Gou; Zhang-Yuan Luo; Wei Li; Wen-Zan Zhang; Yi-Gang Li
Journal:  Exp Ther Med       Date:  2014-04-25       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.