Literature DB >> 20568918

The use of a hybrid dynamic stabilization and fusion system in the lumbar spine: preliminary experience.

Matthew B Maserati1, Matthew J Tormenti, David M Panczykowski, Christopher M Bonfield, Peter C Gerszten.   

Abstract

OBJECT: The authors report the use and preliminary results of a novel hybrid dynamic stabilization and fusion construct for the surgical treatment of degenerative lumbar spine pathology.
METHODS: The authors performed a retrospective chart review of all patients who underwent posterior lumbar instrumentation with the Dynesys-to-Optima (DTO) hybrid dynamic stabilization and fusion system. Preoperative symptoms, visual analog scale (VAS) pain scores, perioperative complications, and the need for subsequent revision surgery were recorded. Each patient was then contacted via telephone to determine current symptoms and VAS score. Follow-up was available for 22 of 24 patients, and the follow-up period ranged from 1 to 22 months. Clinical outcome was gauged by comparing VAS scores prior to surgery and at the time of telephone interview.
RESULTS: A total of 24 consecutive patients underwent lumbar arthrodesis surgery in which the hybrid system was used for adjacent-level dynamic stabilization. The mean preoperative VAS score was 8.8, whereas the mean postoperative VAS score was 5.3. There were five perioperative complications that included 2 durotomies and 2 wound infections. In addition, 1 patient had a symptomatic medially placed pedicle screw that required revision. These complications were not thought to be specific to the DTO system itself. In 3 patients treatment failed, with treatment failure being defined as persistent preoperative symptoms requiring reoperation.
CONCLUSIONS: The DTO system represents a novel hybrid dynamic stabilization and fusion construct. The technique holds promise as an alternative to multilevel lumbar arthrodesis while potentially decreasing the risk of adjacent-segment disease following lumbar arthrodesis. The technology is still in its infancy and therefore follow-up, when available, remains short. The authors report their preliminary experience using a hybrid system in 24 patients, along with short-interval clinical and radiographic follow-up.

Entities:  

Mesh:

Year:  2010        PMID: 20568918     DOI: 10.3171/2010.3.FOCUS1055

Source DB:  PubMed          Journal:  Neurosurg Focus        ISSN: 1092-0684            Impact factor:   4.047


  19 in total

1.  Hybrid Surgery Combined with Dynamic Stabilization System and Fusion for the Multilevel Degenerative Disease of the Lumbosacral Spine.

Authors:  Soo Eon Lee; Tae-Ahn Jahng; Hyun Jib Kim
Journal:  Int J Spine Surg       Date:  2015-08-28

2.  Characterization of the behavior of a novel low-stiffness posterior spinal implant under anterior shear loading on a degenerative spinal model.

Authors:  Angela D Melnyk; Jason D Chak; Vaneet Singh; Adrienne Kelly; Peter A Cripton; Charles G Fisher; Marcel F Dvorak; Thomas R Oxland
Journal:  Eur Spine J       Date:  2015-01-06       Impact factor: 3.134

3.  Does hybrid fixation prevent junctional disease after posterior fusion for degenerative lumbar disorders? A minimum 5-year follow-up study.

Authors:  Andrea Baioni; Mario Di Silvestre; Tiziana Greggi; Francesco Vommaro; Francesco Lolli; Antonio Scarale
Journal:  Eur Spine J       Date:  2015-10-13       Impact factor: 3.134

4.  Which radiographic parameters are linked to failure of a dynamic spinal implant?

Authors:  Eike Hoff; Patrick Strube; Antonius Rohlmann; Christian Gross; Michael Putzier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

5.  Magnetic resonance imaging on disc degeneration changes after implantation of an interspinous spacer and fusion of the adjacent segment.

Authors:  Xiaokang Liu; Yingjie Liu; Xiaofeng Lian; Jianguang Xu
Journal:  Int J Clin Exp Med       Date:  2015-04-15

6.  Comparison of standard fusion with a "topping off" system in lumbar spine surgery: a protocol for a randomized controlled trial.

Authors:  Jan Siewe; Christina Otto; Peter Knoell; Marco Koriller; Gregor Stein; Thomas Kaulhausen; Peer Eysel; Kourosh Zarghooni; Jeremy Franklin; Rolf Sobottke
Journal:  BMC Musculoskelet Disord       Date:  2011-10-18       Impact factor: 2.362

7.  Evaluation of efficacy of a new hybrid fusion device: a randomized, two-centre controlled trial.

Authors:  Jan Siewe; Jan Bredow; Johannes Oppermann; Timmo Koy; Stefan Delank; Peter Knoell; Peer Eysel; Rolf Sobottke; Kourosh Zarghooni; Marc Röllinghoff
Journal:  BMC Musculoskelet Disord       Date:  2014-09-05       Impact factor: 2.362

8.  Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience.

Authors:  Ahmed Kashkoush; Nitin Agarwal; Erin Paschel; Ezequiel Goldschmidt; Peter C Gerszten
Journal:  Cureus       Date:  2016-06-10

9.  Role of dynesys as pedicle-based nonfusion stabilization for degenerative disc disorders.

Authors:  Neel Anand; Eli M Baron
Journal:  Adv Orthop       Date:  2012-12-26

10.  Dynamic Fixation Techniques for the Prevention of Adjacent Segment Disease: A Retrospective Controlled Study.

Authors:  Salvador Fuster; Jaime Jesús Martínez-Anda; Sergio Antonio Castillo-Rivera; Caribay Vargas-Reverón; Eduard Tornero
Journal:  Asian Spine J       Date:  2021-06-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.