Literature DB >> 26463865

Does hybrid fixation prevent junctional disease after posterior fusion for degenerative lumbar disorders? A minimum 5-year follow-up study.

Andrea Baioni1, Mario Di Silvestre2, Tiziana Greggi3, Francesco Vommaro4, Francesco Lolli5, Antonio Scarale6.   

Abstract

PURPOSE: Medium- to long-term retrospective evaluation of clinical and radiographic outcome in the treatment of degenerative lumbar diseases with hybrid posterior fixation.
METHODS: Thirty patients were included with the mean age of 47.8 years (range 35 to 60 years). All patients underwent posterior lumbar instrumentation using hybrid fixation for lumbar stenosis with instability (13 cases), degenerative spondylolisthesis Meyerding grade I (6 cases), degenerative disc disease of one or more adjacent levels in six cases and mild lumbar degenerative scoliosis in five patients. Clinical outcomes were evaluated using Oswestry disability index (ODI), Roland and Morris disability questionnaire (RMDQ), and the visual analog scale (VAS) pain scores. All patients were assessed by preoperative, postoperative and follow-up standing plain radiographs and lateral X-rays with flexion and extension. Adjacent disc degeneration was also evaluated by magnetic resonance imaging (MRI) at follow-up.
RESULTS: At a mean follow-up of 6.1 years, we observed on X-rays and/or MRI 3 cases of adjacent segment disease (10.0 %): two of them (6.6 %) presented symptoms and recurred a new surgery. The last patient (3.3 %) developed asymptomatic retrolisthesis of L3 not requiring revision surgery. The mean preoperative ODI score was 67.6, RMDQ score was 15.1, VAS back pain score was 9.5, and VAS leg pain score was 8.6. Postoperatively, these values improved to 28.1, 5.4, 3.1, and 2.9, respectively, and remained substantially unchanged at the final follow-up: (27.7, 5.2, 2.9, and 2.7, respectively).
CONCLUSIONS: After 5-year follow-up, hybrid posterior lumbar fixation presented satisfying clinical outcomes in the treatment of degenerative disease.

Entities:  

Keywords:  Adjacent segment disease; Degenerative lumbar disease; Hybrid posterior fixation

Mesh:

Year:  2015        PMID: 26463865     DOI: 10.1007/s00586-015-4269-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  25 in total

1.  Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients.

Authors:  Wen-Ying Chou; Chien-Jen Hsu; Wei-Ning Chang; Chi-Yin Wong
Journal:  Arch Orthop Trauma Surg       Date:  2002-02       Impact factor: 3.067

2.  Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann; Hadi N Boustani
Journal:  Eur Spine J       Date:  2011-10-20       Impact factor: 3.134

3.  Effect of a posterior dynamic implant adjacent to a rigid spinal fixator.

Authors:  Thomas Zander; Antonius Rohlmann; Nagananda K Burra; Georg Bergmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-06-05       Impact factor: 2.063

Review 4.  The adult scoliosis.

Authors:  Max Aebi
Journal:  Eur Spine J       Date:  2005-11-18       Impact factor: 3.134

Review 5.  Posterior pedicle fixation-based dynamic stabilization devices for the treatment of degenerative diseases of the lumbar spine.

Authors:  Christopher M Bono; Murali Kadaba; Alexander R Vaccaro
Journal:  J Spinal Disord Tech       Date:  2009-07

6.  Lumbosacral spinal fusion. A biomechanical study.

Authors:  C K Lee; N A Langrana
Journal:  Spine (Phila Pa 1976)       Date:  1984-09       Impact factor: 3.468

7.  Insufficient restoration of lumbar lordosis and FBI index following pedicle subtraction osteotomy is an indicator of likely mechanical complication.

Authors:  J C Le Huec; A Cogniet; H Demezon; J Rigal; R Saddiki; S Aunoble
Journal:  Eur Spine J       Date:  2014-12-17       Impact factor: 3.134

Review 8.  Critical analysis of trends in fusion for degenerative disc disease over the past 20 years: influence of technique on fusion rate and clinical outcome.

Authors:  Christopher M Bono; Casey K Lee
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-15       Impact factor: 3.468

9.  Analysis of risk factors for adjacent segment degeneration occurring more than 5 years after fusion with pedicle screw fixation for degenerative lumbar spine.

Authors:  Jaewan Soh; Jae Chul Lee; Byung Joon Shin
Journal:  Asian Spine J       Date:  2013-11-28

10.  Biomechanical evaluation of pedicle screw-based dynamic stabilization devices for the lumbar spine: a systematic review.

Authors:  Cédric Y Barrey; Ravi K Ponnappan; Jason Song; Alexander R Vaccaro
Journal:  SAS J       Date:  2008-12-01
View more
  8 in total

1.  Material failure in dynamic spine implants: are the standardized implant tests before market launch sufficient?

Authors:  Stavros Oikonomidis; Rolf Sobottke; Hans-Joachim Wilke; Christian Herren; Agnes Beckmann; Kourosh Zarghooni; Jan Siewe
Journal:  Eur Spine J       Date:  2019-01-16       Impact factor: 3.134

2.  Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience.

Authors:  Ahmed Kashkoush; Nitin Agarwal; Erin Paschel; Ezequiel Goldschmidt; Peter C Gerszten
Journal:  Cureus       Date:  2016-06-10

3.  Clinical experiences with a PEEK-based dynamic instrumentation device in lumbar spinal surgery: 2 years and no more.

Authors:  Stavros Oikonomidis; Ghazi Ashqar; Thomas Kaulhausen; Christian Herren; Jan Siewe; Rolf Sobottke
Journal:  J Orthop Surg Res       Date:  2018-08-09       Impact factor: 2.359

4.  Adjacent segment degeneration and topping off. Never stop at the apex!

Authors:  Markus R Konieczny; Shejda Mokhaberi; Rüdiger Krauspe
Journal:  Orthop Rev (Pavia)       Date:  2019-06-26

5.  Comparison between topping-off technology and posterior lumbar interbody fusion in the treatment of chronic low back pain: A meta-analysis.

Authors:  Wei Wang; Xiangyao Sun; Tongtong Zhang; Siyuan Sun; Chao Kong; Junzhe Ding; Xiangyu Li; Shibao Lu
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

6.  Dynamic Fixation Techniques for the Prevention of Adjacent Segment Disease: A Retrospective Controlled Study.

Authors:  Salvador Fuster; Jaime Jesús Martínez-Anda; Sergio Antonio Castillo-Rivera; Caribay Vargas-Reverón; Eduard Tornero
Journal:  Asian Spine J       Date:  2021-06-17

Review 7.  Incidence and risk factors of reoperation in patients with adjacent segment disease: A meta-analysis.

Authors:  Major B Burch; Nicholas W Wiegers; Sonal Patil; Ali Nourbakhsh
Journal:  J Craniovertebr Junction Spine       Date:  2020-04-04

8.  The use of the DTO™ hybrid dynamic device: a clinical outcome- and radiological-based prospective clinical trial.

Authors:  Christian Herren; Rolf Sobottke; Miguel Pishnamaz; Max Joseph Scheyerer; Jan Bredow; Leonard Westermann; Eva Maria Berger; Stavros Oikonomidis; Peer Eysel; Jan Siewe
Journal:  BMC Musculoskelet Disord       Date:  2018-06-21       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.