Literature DB >> 20566128

Experience of y-configured stents for small basilar tip aneurysms.

Chun Sung Cho1, Young Joon Kim, Jin Kyung Kim, Young Jin Kim, Sang Koo Lee, Maeng Ki Cho.   

Abstract

SUMMARY: Among posterior circulation aneurysms, basilar tip aneurysm is the most difficult to treat. Because of their deep location in front of the brainstem and their intimate relationship to perforating vessels, morbidity and mortality rates associated with direct exposure used to be daunting. Complex intracranial aneurysms are not uncommonly encountered in cerebrovascular practice. Often their complexity can render standard treatment either impossible or exceedingly hazardous. Although endovascular therapy is an available alternative to surgical clipping, it is not without risks. The Neuroform stent represents a significant advance in the endovascular treatment of intracranial aneurysms. The Y-configured reconstruction method of the Neuroform stent may represent a variable therapeutic option especially in the case of terminal type including bifurcation aneurysms. We report the results of our experience in two small basilar tip aneurysms using stent-assisted coiling.

Entities:  

Year:  2007        PMID: 20566128      PMCID: PMC3329165          DOI: 10.1177/159101990701300105

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  18 in total

1.  The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation.

Authors:  Jay U Howington; Ricardo A Hanel; Mark R Harrigan; Elad I Levy; Lee R Guterman; L Nelson Hopkins
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

2.  Absent relationship between the coil-embolization ratio in small aneurysms treated with a single detachable coil and outcomes.

Authors:  James K Goddard; Christopher J Moran; DeWitte T Cross; Colin P Derdeyn
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

3.  Selective occlusion of basilar artery aneurysms using controlled detachable coils: report of 35 cases.

Authors:  L Pierot; A Boulin; L Castaings; A Rey; J Moret
Journal:  Neurosurgery       Date:  1996-05       Impact factor: 4.654

4.  [Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases].

Authors:  J Moret; C Cognard; A Weill; L Castaings; A Rey
Journal:  J Neuroradiol       Date:  1997-06       Impact factor: 3.447

5.  Neuroform stent deployment for treatment of a basilar tip aneurysm via a posterior communicating artery route.

Authors:  DeWitte T Cross; Christopher J Moran; Colin P Derdeyn; Avi Mazumdar; Dennis Rivet; Michael M Chicoine
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

6.  Microstent-assisted coiling for wide-necked intracranial aneurysms.

Authors:  Marlise Peruzzo dos Santos Souza; Ronit Agid; Robert A Willinsky; Michael Cusimano; Walter Montanera; M Christopher Wallace; Karel G terBrugge; Thomas R Marotta
Journal:  Can J Neurol Sci       Date:  2005-02       Impact factor: 2.104

7.  Endovascular treatment of ruptured posterior circulation aneurysms using electrolytically detachable coils.

Authors:  D A Nichols; R D Brown; K R Thielen; F B Meyer; J L Atkinson; D G Piepgras
Journal:  J Neurosurg       Date:  1997-09       Impact factor: 5.115

8.  Basilar artery to bilateral posterior cerebral artery 'Y stenting' for endovascular reconstruction of wide-necked basilar apex aneurysms: report of three cases.

Authors:  Eimir Perez-Arjona; Richard D Fessler
Journal:  Neurol Res       Date:  2004-04       Impact factor: 2.448

9.  Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.

Authors:  A Fernandez Zubillaga; G Guglielmi; F Viñuela; G R Duckwiler
Journal:  AJNR Am J Neuroradiol       Date:  1994-05       Impact factor: 3.825

10.  Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils.

Authors:  C G McDougall; V V Halbach; C F Dowd; R T Higashida; D W Larsen; G B Hieshima
Journal:  J Neurosurg       Date:  1996-03       Impact factor: 5.115

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.