Literature DB >> 9303942

[Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases].

J Moret1, C Cognard, A Weill, L Castaings, A Rey.   

Abstract

PURPOSE: The main factor limiting endovascular treatment of intracranial aneurysms is the shape of the aneurysmal sac, particularly the width of the neck. In this study we present a new technique to occlude wide neck aneurysms that involves the temporary inflation of a non-detachable balloon in front of the aneurysm neck during each coil placement. The aim of the study is to present the feasibility, efficacy and safety of this "remodeling technique" (RT) as compared to that of "normal" GDC treatment. MATERIAL AND
METHOD: 56 aneurysms in 54 patients were selected for treatment with the RT. Thirty-seven (70%) of the patients presented with subarachnoid hemorrhage. Twenty-five (45%) of the aneurysms were located at the vertebrobasilar artery, 24 (43%) at the internal carotid artery, and seven at the level of smaller arteries.
RESULTS: Treatment was achieved in 52 aneurysms in 50 patients. Two aneurysms which were initially not completely occluded underwent a second treatment using the RT. Final results (i.e. the last follow-up angiography or results at the end of the treatment for the cases that have not yet had follow-up) consisted of total occlusion in 40 cases (77%), sub-total occlusion in nine cases (17%), and incomplete occlusion in three cases (6%). Angiographic evidence of clotting was observed during the procedure in three cases, resulting in one permanent deficit (quadranopia). Rupture of the aneurysmal sac occurred during the procedure in three cases, all of which were asymptomatic in the follow-up. Thus, morbidity due to the technique was 1/52 (0.5%) and mortality was 0/56 patients.
CONCLUSION: The remodeling technique allowed the treatment of 52 wide neck or badly shaped aneurysms that were not treatable without this technique. The results of occlusion with the RT seem better than those in our series of normal GDC treatment, and complications related to the technique are fewer. This technique thereby extends the spectrum of treatable aneurysms without increasing the risk incurred by treatment.

Entities:  

Mesh:

Year:  1997        PMID: 9303942

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  141 in total

1.  Aneurysm endovascular therapy.

Authors: 
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

2.  Bare stent-graft technique: a new method of endoluminal vascular reconstruction for the treatment of giant and fusiform aneurysms.

Authors:  Civan Islak; Naci Kocer; Sait Albayram; Osman Kizilkilic; Omer Uzma; Oktay Cokyuksel
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

3.  Carotid rupture during stent-assisted aneurysm treatment.

Authors:  Hajime Wada; Michel Piotin; Hervé Boissonnet; Laurent Spelle; Charbel Mounayer; Jacques Moret
Journal:  AJNR Am J Neuroradiol       Date:  2004-05       Impact factor: 3.825

4.  Retrieval of malpositioned, dislocated or fractured guglielmi detachable coils from intracranial vessels. A report of seven cases.

Authors:  L E Lampmann; M Sluzewski; W J Van Rooij
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

5.  Importance of the over the wire occlusion balloon catheter designed for intracranial use. Two illustrative cases.

Authors:  A Weill; T Marotta; G Redekop
Journal:  Interv Neuroradiol       Date:  2001-07-15       Impact factor: 1.610

6.  Neck protective basket.

Authors:  K Fukasaku; M Negoro; Y Kamikita; K Oguchi; S Sone
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

7.  Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

Authors:  A O'Hare; J Thornton; P Brennan
Journal:  Interv Neuroradiol       Date:  2009-09-01       Impact factor: 1.610

8.  Remodeling Technique in the Treatment of Intracranial Aneurysms: Indications, Limits and Non-indications.

Authors:  L Spelle; M Piotin; R Blanc; J Moret
Journal:  Interv Neuroradiol       Date:  2008-10-09       Impact factor: 1.610

9.  Retreatment of cerebral aneurysms after guglielmi detachable coil embolization.

Authors:  Y Matsumaru; H Sato; T Takigawa; M Okazaki; T Kamezaki; A Tsukada; T Nose; N Nakai; M Sonobe
Journal:  Interv Neuroradiol       Date:  2008-06-09       Impact factor: 1.610

Review 10.  Endovascular management of cerebral aneurysm : review of the literature.

Authors:  Mario Zanaty; Nohra Chalouhi; Stavropoula I Tjoumakaris; Robert H Rosenwasser; Pascal M Jabbour
Journal:  Transl Stroke Res       Date:  2013-11-24       Impact factor: 6.829

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.