Literature DB >> 11494193

Monitoring in-shoe plantar pressures, temperature, and humidity: reliability and validity of measures from a portable device.

K S Maluf1, R E Morley, E J Richter, J W Klaesner, M J Mueller.   

Abstract

OBJECTIVE: To investigate the reliability and validity of measures obtained from a portable electronic device used to monitor changes in plantar pressure, temperature, and humidity that occur within the shoe during prolonged activity.
DESIGN: Descriptive study comparing electronic sensor output with criterion values. SETTINGS: Indoor level walkway for pressure data; uncontrolled, outdoor environment for step count data; enclosed environmental control chamber for humidity and temperature data. PARTICIPANTS: Convenience sample of 4 healthy, sensate subjects.
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Correlations between sensor output and criterion measures were determined for pressure and temperature data. The absolute differences between sensor output and criterion values of temperature, humidity, and step count were also determined.
RESULTS: Pressure measurements from electronic sensors correlated highly with criterion values (r > or =.82), both before and after prolonged use. Relative humidity sensor output were within 5% of hygrometer values. In-shoe temperature data correlated highly with criterion values (r > or =.99), and differed from known temperatures by.50 degrees +/-.84 degrees C and.96 degrees +/- 1.56 degrees C at the forefoot and heel, respectively. Electronic step counts recorded at the central forefoot were within 1 step of visual step counts. Pressure tracings obtained from the device during different weight-bearing activities revealed qualitatively distinct pressure patterns.
CONCLUSION: The device provides valid and reliable measures of in-shoe plantar pressures, temperature, and humidity during prolonged activity.

Entities:  

Mesh:

Year:  2001        PMID: 11494193     DOI: 10.1053/apmr.2001.24223

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  6 in total

1.  Reliability of the TekScan MatScan(R) system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults.

Authors:  Gerard V Zammit; Hylton B Menz; Shannon E Munteanu
Journal:  J Foot Ankle Res       Date:  2010-06-18       Impact factor: 2.303

2.  Prediction of Diabetic Foot Ulceration: The Value of Using Microclimate Sensor Arrays.

Authors:  Petra Jones; Richard Bibb; Melanie Davies; Kamlesh Khunti; Matthew McCarthy; David Webb; Francesco Zaccardi
Journal:  J Diabetes Sci Technol       Date:  2019-10-09

Review 3.  Real-time human ambulation, activity, and physiological monitoring: taxonomy of issues, techniques, applications, challenges and limitations.

Authors:  Rinat Khusainov; Djamel Azzi; Ifeyinwa E Achumba; Sebastian D Bersch
Journal:  Sensors (Basel)       Date:  2013-09-25       Impact factor: 3.576

4.  Portable System for Monitoring the Microclimate in the Footwear-Foot Interface.

Authors:  José de Jesús Sandoval-Palomares; Javier Yáñez-Mendiola; Alfonso Gómez-Espinosa; José Martin López-Vela
Journal:  Sensors (Basel)       Date:  2016-07-08       Impact factor: 3.576

5.  Footwear microclimate and its effects on the microbial community of the plantar skin.

Authors:  Te Miao; Peihua Wang; Nan Zhang; Yuguo Li
Journal:  Sci Rep       Date:  2021-10-13       Impact factor: 4.379

6.  Normal foot loading parameters and repeatability of the Footscan® platform system.

Authors:  Chao Xu; Xin-Xin Wen; Lu-Yu Huang; Lei Shang; Xi-Xia Cheng; Ya-Bo Yan; Wei Lei
Journal:  J Foot Ankle Res       Date:  2017-07-17       Impact factor: 2.303

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.