Defibrillation efficacy. Comparison of defibrillation threshold versus dose-response curve determination.

D L Jones1, W D Irish, G J Klein.   

Abstract

When an automatic defibrillator is implanted, it is essential to determine the efficacy of the defibrillating system accurately, while balancing the need to keep the number of fibrillation episodes to a minimum. Two methods have evolved to assess defibrillation efficacy: 1) the "defibrillation threshold," which requires few ventricular fibrillation episodes, and 2) the "dose-response curve," which requires many ventricular fibrillation episodes and relates percent success to energy. The purpose of this study was to compare these two methods directly. Twenty open-chest anesthetized pigs had triplicate defibrillation threshold determinations. To produce a dose-response curve, six shocks then were delivered at 0.5, 0.75, 1.0, 1.25, 1.5, and 2.0 times the mean defibrillation threshold, in a balanced randomized order, during separate episodes of ventricular fibrillation. The data were fitted by logistic regression, conversions of the logistic regression, and a saturable exponential and nonsaturable growth exponential. A comparison was made of the mean defibrillation threshold and the 50% point on the dose-response curve (ED50) for each model, for each animal. In addition, the reliability of each measure was assessed by comparing the coefficients of variation. There was no statistical difference between the group defibrillation threshold (6.6 +/- 0.5 J) and group ED50 values (ED50 range of the models, 5.7 +/- 1.9 to 7.0 +/- 0.9 J). However, the variability about the defibrillation threshold was less than that of the ED50 values for all mathematical models except the true logistic equation, which was virtually the same.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 2054941     DOI: 10.1161/01.res.69.1.45

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  9 in total

1.  [Single- and dual-chamber ICDs: Are there still significant differences compared to pacemakers with regard to implantation and follow-up?].

Authors:  M Stockburger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

2.  Success--failure diagram for defibrillation.

Authors:  L A Geddes
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

3.  Early postoperative rise in defibrillation threshold associated with hematoma formation with unipolar defibrillation system.

Authors:  D Y Yazmajian; D Schwartzman; D J Callans; C D Gottieb; F E Marchlinski
Journal:  J Interv Card Electrophysiol       Date:  1997-09       Impact factor: 1.900

Review 4.  The Saga of Defibrillation Testing: When Less Is More.

Authors:  Marye J Gleva; Melissa Robinson; Jeanne Poole
Journal:  Curr Cardiol Rep       Date:  2018-05-05       Impact factor: 2.931

5.  Azimilide decreases defibrillation voltage requirements and increases spatial organization during ventricular fibrillation.

Authors:  X Q Qi; D Newman; P Dorian
Journal:  J Interv Card Electrophysiol       Date:  1999-03       Impact factor: 1.900

6.  A randomized comparison of defibrillation thresholds in the right ventricular outflow tract versus right ventricular apex.

Authors:  Michael Mollerus; Margaret Lipinski; Thomas Munger
Journal:  J Interv Card Electrophysiol       Date:  2008-05-10       Impact factor: 1.900

7.  Minimum energy single-shock internal atrial defibrillation in sheep.

Authors:  Amy M Goodman; Merlise A Clyde; Donald S Burdick; Salim F Idriss; Patrick D Wolf
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

8.  Right ventricular insertion promotes reinitiation of ventricular fibrillation in defibrillation failure.

Authors:  Kenichi Iijima; Hanyu Zhang; Matthew T Strachan; Jian Huang; Gregory P Walcott; Jack M Rogers
Journal:  Heart Rhythm       Date:  2021-01-26       Impact factor: 6.779

9.  Current concepts on ventricular fibrillation: a vicious circle of cardiomyocyte calcium overload in the initiation, maintenance, and termination of ventricular fibrillation.

Authors:  Christian E Zaugg
Journal:  Indian Pacing Electrophysiol J       Date:  2004-04-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.