Literature DB >> 20545533

Crown-to-implant ratios of short-length implants.

Hardeep Birdi1, John Schulte, Alejandro Kovacs, Meghan Weed, Sung-Kiang Chuang.   

Abstract

Excessive crown-implant ratios have been cited in the literature as being detrimental to long-term implant survival. However, unfavorable crown-implant ratios have not yet been established. The primary aim of this study was to determine the crown-implant ratios of single-tooth implant-supported restorations on short-length implants in a clinical practice, and to evaluate the health of these implants via mesial and distal first bone-to-implant contact levels. Additionally, the relationship between crown-implant ratios and proximal first bone-to-implant contact levels will be evaluated. In this retrospective cohort study, the cohort was composed of 194 patients who possessed at least 1 single 5.7 mm or 6 mm length plateau design implant-supported restoration that had been surgically placed between February 1997 and December 2005. A chart review was performed to acquire the most recent radiographs in which both the entire crown and the implant were visible. The length of the crown and implant was measured directly from the radiographs using consistent magnification to calculate the crown-implant ratio. Mesial and distal first bone-to-implant contact levels were measured using 3 times magnification and were mathematically corrected for distortion. The last available radiograph was used to measure bone levels. Follow-up time was calculated from the day of implant placement to the date of the last available radiograph. Statistical analyses with analysis of variance mixed models were used. Data from 309 single implant-supported fixed restorations were tabulated and included in the study. The mean (SD) follow-up time was 20.9 (23.2) months, with a range of 15.6 to 122.8 months. The mean crown length (SD) was 13.4 (2.6) mm, with a range of 6.2 to 21.7 mm. The mean (SD) crown-implant ratio was 2.0 (0.4) and ranged from 0.9 to 3.2. The average mesial and distal first bone-to-implant contact levels (SD) measured from the radiographs were -0.2 (0.7) mm and -0.2 (0.9) mm, respectively. No statistically significant relationship was observed between increasing crown-implant ratios and decreasing mesial and distal first bone-to-implant contact levels around the implant with P values of .94 and .57, respectively. In this investigation, mesial and distal first bone-to-implant contact levels on short-length implants fall within the established guidelines for success. Also, there are no associations between crown-implant ratios and first bone-to-implant contact levels.

Entities:  

Mesh:

Year:  2010        PMID: 20545533     DOI: 10.1563/AAID-JOI-D-09-00071

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  15 in total

1.  Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis.

Authors:  Pinar Ercal; Aysegul Erten Taysi; Demet Cagil Ayvalioglu; Meltem Mert Eren; Soner Sismanoglu
Journal:  Med Biol Eng Comput       Date:  2021-03-17       Impact factor: 2.602

Review 2.  Short Implants: New Horizon in Implant Dentistry.

Authors:  Neha Jain; Manisha Gulati; Meenu Garg; Chetan Pathak
Journal:  J Clin Diagn Res       Date:  2016-09-01

3.  Survival of immediately versus delayed loaded short implants: A prospective case series study.

Authors:  Joaquin Alvira-González; Erick Díaz-Campos; Maria-Angeles Sánchez-Garcés; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

Review 4.  Short dental implants in reduced alveolar bone height: a review of the literature.

Authors:  Marcin Tutak; Tomasz Smektała; Katarzyna Schneider; Edyta Gołębiewska; Katarzyna Sporniak-Tutak
Journal:  Med Sci Monit       Date:  2013-11-21

5.  Cumulative Success Rate of Short and Ultrashort Implants Supporting Single Crowns in the Posterior Maxilla: A 3-Year Retrospective Study.

Authors:  Giorgio Lombardo; Jacopo Pighi; Mauro Marincola; Giovanni Corrocher; Miguel Simancas-Pallares; Pier Francesco Nocini
Journal:  Int J Dent       Date:  2017-07-02

6.  Full mouth rehabilitation with retrievable metal-ceramic implant-supported fixed prostheses for a young patient with atrophic jaws: a clinical report.

Authors:  Narges Ameri; Marzieh Alikhasi; Vida Rezayani
Journal:  Clin Case Rep       Date:  2017-08-10

Review 7.  Short dental implants in the posterior maxilla: a review of the literature.

Authors:  Zeinab Rezaei Esfahrood; Loghman Ahmadi; Elahe Karami; Shima Asghari
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2017-04-25

8.  Guided bone regeneration using K-incision technique.

Authors:  Young-Dan Cho; Young Ku
Journal:  J Periodontal Implant Sci       Date:  2018-06-30       Impact factor: 2.614

Review 9.  Predictability of short implants ( < 10 mm) as a treatment option for the rehabilitation of atrophic maxillae. A systematic review.

Authors:  J-L Sierra-Sánchez; F García-Sala-Bonmatí; A Martínez-González; C García-Dalmau; J-F Mañes-Ferrer; A Brotons-Oliver
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-05-01

10.  The Influence of the Crown-Implant Ratio on the Crestal Bone Level and Implant Secondary Stability: 36-Month Clinical Study.

Authors:  Jakub Hadzik; Maciej Krawiec; Konstanty Sławecki; Christiane Kunert-Keil; Marzena Dominiak; Tomasz Gedrange
Journal:  Biomed Res Int       Date:  2018-05-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.