Literature DB >> 15151338

Comparison of PAC and QTH light sources on polymerization of resin composites.

Nobuhiro Katahira1, Richard M Foxton, Norimichi Inai, Masayuki Otsuki, Junji Tagami.   

Abstract

PURPOSE: To evaluate the polymerization shrinkage, Knoop hardness number (KHN) and compressive strength and to suggest a suitable time for irradiating resin composite restorations, when using a high-intensity light source.
METHODS: Two restorative resin composites, UniFil F, and Clearfil AP-X were employed. A high-intensity light unit (more than 1000mW/cm2) with a xenon discharge lamp (Apollo 95E), which is generally called a plasma arc light-curing unit (PAC), was compared with a conventional light-curing unit fitted with a quartz-tungsten-halogen lamp (QTH) (GC Newlight VL2). The resin composites were exposed to the light in four ways. For QTH, the irradiation time was for 40 seconds (QTH 40 seconds). For PAC, 3 seconds (PAC 3 seconds), 3+3 seconds (PAC 3+3 seconds) and 3+3+3 seconds (PAC 3+3+3 seconds) was used. Polymerization shrinkage using the bonded disk technique developed by Watts, Knoop hardness number (KHN), and compressive strength were then determined.
RESULTS: Two-way ANOVA revealed that the two materials for PAC 3+3 seconds and PAC 3+3+3 seconds made no difference in polymerization shrinkage compared to QTH 40 seconds (P < 0.001). The polymerization shrinkage of the materials cured by PAC for 3 seconds was significantly lower than those cured by QTH for 40 seconds in a range from 61% to 72%, by the PAC for 3 + 3 seconds in a range from 65% to 88%, and those by PAC 3+3+3 seconds in a range of 61% to 72% (P < 0.001). With regard to microhardness, the composites in PAC 3+3+3 seconds exposure made no difference in hardness compared with QTH 40 seconds (P < 0.001). PAC 3+3 seconds exposure gave hardness at less than 3.0 mm depth equivalent to that of the QTH 40 seconds. PAC 3 seconds at 2.0 mm depth produced inferior hardness compared with the QTH 40 seconds. The compressive strength for the PAC 3 seconds exposure was significantly lower than that of PAC 3+3 seconds, PAC 3+3+3 seconds and QTH 40 seconds for each material. CLINICAL SIGNIFICANCE: Irradiation by the high-intensity light source for 3 seconds provided significantly lower microhardness and compressive strength for light-cured resin composites. The 3+3+3 seconds repeated irradiation with the PAC unit and QTH 40 second values were not significantly different.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15151338

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  3 in total

1.  Diode-pumped solid-state laser for bonding orthodontic brackets: effect of light intensity and light-curing time.

Authors:  Young-Oh Kim; Soo-Byung Park; Woo-Sung Son; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2010-06-08       Impact factor: 3.161

2.  Effect of light-curing units on the thermal expansion of resin nanocomposites.

Authors:  Jeong-Kil Park; Bock Hur; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Am J Dent       Date:  2010-12       Impact factor: 1.522

3.  Micro-hardness evaluation of a micro-hybrid composite resin light cured with halogen light, light-emitting diode and argon ion laser.

Authors:  Katia M Rode; Patricia M de Freitas; Patricia R Lloret; Lynn G Powell; Miriam L Turbino
Journal:  Lasers Med Sci       Date:  2007-12-05       Impact factor: 3.161

  3 in total