Literature DB >> 12541253

Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast.

Jong B Park1, Eric W Olcott, Dwight G Nishimura.   

Abstract

A novel ungated spiral phase-contrast (USPC) imaging method was developed for rapid measurement of time-averaged blood-flow rates in the presence of pulsatility. The spatial point-spread function was analyzed to provide an intuitive understanding of how spiral trajectories, which sample the k-space origin at every excitation, can mitigate the effects of pulsatility. Pulsatile flow phantom experiments were performed to validate the accuracy and repeatability of the USPC method. The measurement of flow in the renal and femoral arteries of normal volunteers were also performed. The phantom results (error < or = +9%, SD(phantom) < or = 2%, time-averaged pulsatile-flow rates = 3-15 ml/s) and in vivo results (SD(renal) < or = 8%, SD(femoral) < or = 14%) demonstrate the potential of the USPC method for rapidly and repeatedly measuring accurate time-averaged blood flow even in relatively small arteries and in the presence of strong pulsatility. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12541253     DOI: 10.1002/mrm.10369

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

Review 1.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

2.  Highly accelerated aortic 4D flow MR imaging with variable-density random undersampling.

Authors:  Jing Liu; Petter Dyverfeldt; Gabriel Acevedo-Bolton; Michael Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2014-05-17       Impact factor: 2.546

3.  Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Authors:  Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner
Journal:  MAGMA       Date:  2017-08-07       Impact factor: 2.310

4.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

5.  Phase-contrast velocimetry with simultaneous fat/water separation.

Authors:  Kevin M Johnson; Oliver Wieben; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

6.  Accelerated aortic flow assessment with compressed sensing with and without use of the sparsity of the complex difference image.

Authors:  Yongjun Kwak; Seunghoon Nam; Mehmet Akçakaya; Tamer A Basha; Beth Goddu; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-10-12       Impact factor: 4.668

Review 7.  Consensus-Based Technical Recommendations for Clinical Translation of Renal Phase Contrast MRI.

Authors:  Anneloes de Boer; Giulia Villa; Octavia Bane; Michael Bock; Eleanor F Cox; Ilona A Dekkers; Per Eckerbom; Maria A Fernández-Seara; Susan T Francis; Bryan Haddock; Michael E Hall; Pauline Hall Barrientos; Ingo Hermann; Paul D Hockings; Hildo J Lamb; Christoffer Laustsen; Ruth P Lim; David M Morris; Steffen Ringgaard; Suraj D Serai; Kanishka Sharma; Steven Sourbron; Yasuo Takehara; Andrew L Wentland; Marcos Wolf; Frank G Zöllner; Fabio Nery; Anna Caroli
Journal:  J Magn Reson Imaging       Date:  2020-11-02       Impact factor: 5.119

8.  Inter-study reproducibility of interleaved spiral phase velocity mapping of renal artery haemodynamics.

Authors:  Jennifer Keegan; Hitesh C Patel; Robin M Simpson; Raad H Mohiaddin; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-04       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.