Literature DB >> 20511437

A review of squeaking hips.

William L Walter1, Eric Yeung, Christina Esposito.   

Abstract

The incidence of squeaking in hip replacement varies for ceramic-on-ceramic and metal-on-metal bearings, and the implications are not fully understood. Contributing factors may include component malposition, edge loading, impingement, third-body particles, and loss of lubrication. However, squeaking is multifactorial, requiring a certain combination of interaction among patient, surgical, and implant factors. When squeaking is infrequent and function is not impaired, patients should avoid activities that precipitate the squeaking. Surgery is recommended for persistent or troublesome squeaking, severe malpositioning of components, failure of the implants (including fracture), impingement and subluxation, and pain. If necessary, the bearing can be changed during surgery to another ceramic-on-ceramic or to a ceramic-on-polyethylene bearing.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20511437     DOI: 10.5435/00124635-201006000-00004

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  18 in total

Review 1.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Painless squeaking following cervical disc replacement: A case report.

Authors:  Athar Siddiqui; Neil Wickham; Christopher Hulme
Journal:  Int J Spine Surg       Date:  2015-08-12

3.  Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.

Authors:  Denis Nam; Toby Barrack; Staci R Johnson; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  CORR Insights(®): Hard-on-hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.

Authors:  Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2016-04-22       Impact factor: 4.176

Review 5.  The basic science of periprosthetic osteolysis.

Authors:  M J Archibeck; J J Jacobs; K A Roebuck; T T Glant
Journal:  Instr Course Lect       Date:  2001

Review 6.  What are the current clinical issues in wear and tribocorrosion?

Authors:  Daniel J Berry; Matthew P Abdel; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

7.  Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings.

Authors:  T Bouras; T Repantis; P Fennema; P Korovessis
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12

8.  Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.

Authors:  Seung-Jae Lim; Seung-Pil Jang; Dong-Wook Kim; Young-Wan Moon; Youn-Soo Park
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

9.  Catastrophic failure of ceramic-on-ceramic total hip arthroplasty presenting as squeaking hip.

Authors:  David Malem; Mathias Thomas Nagy; Sabyasachi Ghosh; Bhavik Shah
Journal:  BMJ Case Rep       Date:  2013-02-20

10.  The basic science of periprosthetic osteolysis.

Authors:  Stuart B Goodman; Emmanuel Gibon; Zhenyu Yao
Journal:  Instr Course Lect       Date:  2013
View more